• Title/Summary/Keyword: Side mirror

Search Result 110, Processing Time 0.024 seconds

A Study on the Fashion Illustration of 17th Century (17세기 복식디자인화에 관한 연구)

  • 이순홍;황수정
    • The Research Journal of the Costume Culture
    • /
    • v.2 no.2
    • /
    • pp.395-413
    • /
    • 1994
  • Costume is mirror of diverse life styles and attitudes in human life. It has a meaning beyond "clothing" . Fashion illlustration is to express these costumes with a picture. So, it can be said that it is a ′mirror of costumes′ in historical side. The purpose of this study is to find the meaning of fashion illustration of 17th century, which called its first one and to look into its characteristics and costumes of 17th century respotlighting fashion illustrators and painters related with fashion illustration in those days. This study is based on Western Europe by literatures. The fashion illustration in 17th century designed by painters and fashion illustrators. They are Wenceslaus Hollar, Abraham Bosse, Jacques Callot, Jean de st Jean, N. Bonar, A. Trouvain, A. Arnoult in France and so on. The characteristics of fashion illustration in 17th century are as follows : 1. There was a quickening of modern civil consciousness in 17th century. As the subject of costume culture moved from noble class to the working class which began to have a free, the fashion illustration changed to the direction of informing their social class and job. 2. The fashion illustrations of 17th century showed storng realism which was a base of modern picture. 3. The most of them showed costume plates. It was not to transmit adding intended forecast but to describe sincerely in costumes′ record. However, the fashion illustration since the middle of 17th century was designed considering fashion. 4. It could be said that the fashion illustration of 17th century was the forest one of today. It was expressed by Wenceslaus Hollar′s ones. And it is found in his suggestion of popular costumes before and behind and delicate description like accessories. 5. They were transmitted by fashion magazines internationally. Le Mercure Galant, which printed mode plates in 1678, was the first modern fashion magazine aiming at general readers. The fashion illustration of 17th century can divide into ones for court, for working classes, costume plates. The fashion illustrations for court designed by court painters. There were court costumes of early time, spanish Mode and of lately time, French Court Culture. They had baroque elements with a bunddle of ribbons and race decoration. On the other hand, the fashion iooustrations for working class were under the influence on Netherlands styles. They were designed for the purpose of god function and much use. That′s why was under the influence of puritanical life creed. In this situation, the costume plates directed the fashion in those days. At that time, they were supplied widely and it amy be an attempt of popularization. The fashion illustrations of 17th century appeared that they had transmissible character and artistics expression. On the basis of them, we can look into the fashion illustrations of today.

  • PDF

A New Design of Power Folding Controller for Deterioration Detection (열화방지형 파워폴딩 제어기 설계에 관한 연구)

  • Kim, Ji-Hyeon;Lee, Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is a study of a prevention of power folding controller's thermal degradation. Power folding technology has been applied for many fields such as side rear vision mirror of vehicles, windshield wiper, antenna, power window. These controllers have been comprised with traditional DC moors, Switching electronic devices, and relays. But this methods have a limitation to overcome such problems of product reliability, endurance, noise margins. Therefore on this paper, to detect the movement of motor, sensing motor brush noise on a load sensing part has been used and controlling a precise RC timing control minimizes the thermal deterioration of motor. And using MOS FETs as a electronic switching device increases life-time and liability of control circuit. After testing such circuit and control method, repetition of operating time, cut-off time, wide operation voltage, power noise margin ware increased over eleven-fold.

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

Microscopic Studies of the Magnetic and Thermal Properties in Ba-ferrite Single Crystal (Ba-Ferrite 단결정의 자기적 및 열적 현상에 관한 미시적 연구)

  • Sur, J.C.;Choi, J.W.
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.4
    • /
    • pp.152-155
    • /
    • 2009
  • Ba-Ferrite single crystals were prepared and the magnetic and thermal properties were characterized by Mossbauer spectroscopy. The single crystal layer was cut in the c-axis and radiated to the surface by ${\gamma}$-rays for Mossbauer spectroscopy. We found out that the spin states in Fe ions were parallel to the ${\gamma}$-rays direction and the whole crystal bulk formed only one crystal with the same spin direction. $M\"{o}ssbauer$ spectra in single crystal have only 4 sets of 4 absorption lines in each Fe site when the ${\gamma}$-rays have the same radiation direction with the c-axis in the crystal, and there was no 2b-site spectrum. The zero absorption of 2b-site means that there was a fast diffusion motion in a double-well atomic potential at room temperature, in which bipyramidal Fe ions have the two minima at each side mirror plane.

A Study on the Classification of Fault Motors using Sound Data (소리 데이터를 이용한 불량 모터 분류에 관한 연구)

  • Il-Sik, Chang;Gooman, Park
    • Journal of Broadcast Engineering
    • /
    • v.27 no.6
    • /
    • pp.885-896
    • /
    • 2022
  • Motor failure in manufacturing plays an important role in future A/S and reliability. Motor failure is detected by measuring sound, current, and vibration. For the data used in this paper, the sound of the car's side mirror motor gear box was used. Motor sound consists of three classes. Sound data is input to the network model through a conversion process through MelSpectrogram. In this paper, various methods were applied, such as data augmentation to improve the performance of classifying fault motors and various methods according to class imbalance were applied resampling, reweighting adjustment, change of loss function and representation learning and classification into two stages. In addition, the curriculum learning method and self-space learning method were compared through a total of five network models such as Bidirectional LSTM Attention, Convolutional Recurrent Neural Network, Multi-Head Attention, Bidirectional Temporal Convolution Network, and Convolution Neural Network, and the optimal configuration was found for motor sound classification.

Hierarchical Flow-Based Anomaly Detection Model for Motor Gearbox Defect Detection

  • Younghwa Lee;Il-Sik Chang;Suseong Oh;Youngjin Nam;Youngteuk Chae;Geonyoung Choi;Gooman Park
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.6
    • /
    • pp.1516-1529
    • /
    • 2023
  • In this paper, a motor gearbox fault-detection system based on a hierarchical flow-based model is proposed. The proposed system is used for the anomaly detection of a motion sound-based actuator module. The proposed flow-based model, which is a generative model, learns by directly modeling a data distribution function. As the objective function is the maximum likelihood value of the input data, the training is stable and simple to use for anomaly detection. The operation sound of a car's side-view mirror motor is converted into a Mel-spectrogram image, consisting of a folding signal and an unfolding signal, and used as training data in this experiment. The proposed system is composed of an encoder and a decoder. The data extracted from the layer of the pretrained feature extractor are used as the decoder input data in the encoder. This information is used in the decoder by performing an interlayer cross-scale convolution operation. The experimental results indicate that the context information of various dimensions extracted from the interlayer hierarchical data improves the defect detection accuracy. This paper is notable because it uses acoustic data and a normalizing flow model to detect outliers based on the features of experimental data.

Luminous Characteristics of Transparent Field Emitters Produced by Using Ultra-thin Films of Single Walled Carbon Nanotubes

  • Jang, Eun-Soo;Goak, Jeung-Choon;Lee, Han-Sung;Lee, Seung-Ho;Lee, Nae-Sung
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.31.1-31.1
    • /
    • 2009
  • Carbon nanotubes (CNTs) are attractive material because of their superior electrical, mechanical, and chemical properties. Furthermore, their geometric features such as a large aspect ratio and a small radius of curvature at tip make them ideal for low-voltage field emission devices including backlight units of liquid crystal display, lighting lamps, X-ray source, microwave amplifiers, electron microscopes, etc. In field emission devices for display applications, the phosphor anode is positioned against the CNT emitters. In most case, light generated from the phosphor by electron bombardment passes through the anode front plate to reach observers. However, light is produced in a narrow depth of the surface of the phosphor layer because phosphor particles are big as much as several micrometers, which means that it is necessary to transmit through the phosphor layer. Hence, a drop of light intensity is unavoidable during this process. In this study, we fabricated a transparent cathode back plate by depositing an ultra-thin film of single walled CNTs (SWCNTs) on an indium tin oxide (ITO)-coated glass substrate. Two types of phosphor anode plates were employed to our transparent cathode back plate: One is an ITO glass substrate with a phosphor layer and the other is a Cr-coated glass substrate with phosphor layer. For the former case, light was radiated from both the front and the back sides, where luminance on the back was ~30% higher than that on the front in our experiments. For the other case, however, light was emitted only from the cathode back side as the Cr layer on the anode glass rolled as a reflecting mirror, improving the light luminance as much as ~60% compared with that on the front of one. This study seems to be discussed about the morphologies and field emission characteristics of CNT emitters according to the experimental parameters in fabricating the lamps emitting light on the both sides or only on the cathode back side. The experimental procedures are as follows. First, a CNT aqueous solution was prepared by ultrasonically dispersing purified SWCNTs in deionized water with sodium dodecyl sulfate (SDS). A milliliter or even several tens of micro-liters of CNT solution was deposited onto a porous alumina membrane through vacuum filtration. Thereafter, the alumina membrane was solvated with the 3 M NaOH solution and the floating CNT film was easily transferred to an ITO glass substrate. It is required for CNT film to make standing CNTs up to serve as electron emitter through an adhesive roller activation.

  • PDF

THE PREVALENCE OF DOUBLE TEETH AND CONGENITAL MISSING TEETH IN PRESCHOOL CHILDREN OF IKSAN CITY (익산지역 유치원 아동의 이중치와 결손치의 발생빈도에 관한 조사 연구)

  • Ju, Jin-Hyung;Lee, Kwang-Hee;Kim, Dae-Eop;Jeong, Young-Nam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.210-216
    • /
    • 2003
  • The double teeth include gemination and fusion. The congenital missing tooth is the absence of the tooth. The purpose of this study was to investigate the prevalence of double teeth and congenital missing teeth in preschool children of Iksan city. The study population consisted of 1,031 children, 569 boys and 462 girls, aged from 17 to 84 months. The double teeth possess a variety of diagnostic and treatment problems. Gemination is the partial splitting of a single bud into two distinct entities that remain joined in a Siamese twin fashion. Fusion is the joining of two buds. Both may be normal, or one may be a supernumerary tooth. Congenital missing is the absence of one or a few teeth. Twenty three(11 boys and 12 girls) of the 1,031 children had double teeth and 17(8 boys and 9 girls) exhibited congenital missing of teeth. The prevalence of double primary teeth was 2.2%. The prevalence of congenital missing teeth was 1.6%. One subject had double teeth and congenital missing tooth at the same time. Of the 17 cases of congenital missing teeth, one girl showed it in the maxilla and aye boys and six girls had them in the unilateral side of the mandible. There were no significant differences in the prevalence of double teeth and congenital missing teeth between the boys and the girls.

  • PDF

Is Skeletonized Internal Mammary Artery Harvesting better than Pedicled Harvesting in Respect of the Sternal Blood Flow\ulcorner: An Estimation Using Bone Scan (내유동맥의 골격화 채취는 흉골로의 혈류 감소 측면에서 과연 유리한가 \ulcorner: 골주사를 이용한 평가)

  • 손국희;김영삼;김정택;윤용한;김광호;최원식;백완기
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.511-516
    • /
    • 2004
  • Background: One of the theoretical advantages of skeletonized internal mammary artery harvesting in coronary artery bypass surgery is to minimize the interruption of the sternal blood flow inevitably accompanied by internal mammary harvesting. A study using bone scan is designed to determine the effects of internal mammary artery harvesting technique on the sternal blood flow. Material and Method: From April 2002 to March 2003, 27 patients out of 48 patients who underwent the isolated coronary bypass surgery were enrolled into the study. The enrolled patients underwent bone scan in the preoperative period and postoperative period respectively. Bilateral internal mammary artery was used in 8 patients (BIMA group) and single left internal mammary artery in 19 patients (LIMA group). The patients in LIMA group were divided into two groups: LlMA_skel group, in whom left internal mammary artery was harvested in skeletonized fashion (n=12), and LlMA_ped group, in whom left internal mammary artery was harvested in pedicled fashion (n=7). After the bone scan, the region of interest (ROI) was created on the left of the sternum and the mirror image with the same pixel numbers was placed on the right half of the sternum. The mean counts per pixel on the left side of the sternum was compared with those on the right side and expressed as left to right ratio (L/R ratio). Result: In LIMA group, the L/R ratio decreased from 94.6$\pm$4.1% to 87.9$\pm$6.9% (p=0.003) after the operation as compared to BIMA group, in which no change of the L/R ratio was observed. The changed of the L/R ratio in LlMA_skel group and LlMA_ped group were from 95.3$\pm$4.2% to 88.3$\pm$7.7% and from 93.4$\pm$3.9% to 87.4$\pm$5.8% respectively. The % changes in L/R ratio were -7.44 $\pm$7.08 in LIMA_skel group and -6.17$\pm$9.08 in LiMA_ped group, which did not reach the statistical difference. Conclusion: Ipsilateral sternal blood flow is interrupted by internal mammary artery harvesting as evidenced by the decrease in L/R ratio after left internal mammary artery harvesting irrespective of the harvesting techniques. Skeletonized harvesting did not show superiority in respect to sternal blood flow as compared to pedicled harvesting.

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF