• Title/Summary/Keyword: Side image

Search Result 1,027, Processing Time 0.025 seconds

Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position (Supine 자세에서 Shoulder oblique촬영시 Tube angle 변화에 따른 Shoulder joint에 대한 고찰)

  • Seo, Jae-Hyun;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.109-114
    • /
    • 2008
  • There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were $1.10{\pm}0.54$ at $25^{\circ}$, $2.50{\pm}0.50$ at 30^{\circ}$, $2.85{\pm}0.36$ at $35^{\circ}$ and $2.33{\pm}0.47$ at $40^{\circ}$, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at $35^{\circ}$, $30^{\circ}$ and $40^{\circ}$ with the almost same score. However, the degree of distortion at $40^{\circ}$ was more severe than that at $30^{\circ}$. Ultimately, $30-35^{\circ}$ views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  • PDF

A Study on Efficiently Designing Customer Rewards Programs (고객 보상프로그램의 효율적 구성에 관한 연구)

  • Kim, Sang-Cheol
    • Journal of Distribution Science
    • /
    • v.10 no.1
    • /
    • pp.5-10
    • /
    • 2012
  • Currently, the rewards programs offered by many companies to strengthen customer relationships have been working quite well. In addition, many companies' rewards programs, designed for stabilizing revenue, are recognized to be effective. However, these rewards programs are not significantly differentiated between companies and there are no accurate conclusions currently, which can be made about their effects. Because of this, a company with a customer rewards program may not comprehend the true level of active participation. In this environment some companies' rewards programs inadvertently hinder business profitability as a side effect while attempting to increase customer loyalty. In fact, airline and oil companies pass on the financial cost of their programs to the customer, and as a result, they have been criticized publicly. The result of this is that the corporations with bad rewards programs tend to get a bad image. In this study of stores' rewards programs, we centered our focus on the design of the program. The main problem in this study is to recognize the financial value of the rewards program and whether it can create a competitive edge for the companies despite the cost issues experienced by them. Customers receiving financial rewards for their business may be just as satisfied with a particular company or store versus those who are not, and the program, perhaps, does not form a distinctive competitive advantage. When the customer is deciding between competing companies to secure their product needs with, we wanted to figure out how much of an affect a valuable reward program had on their decision making. To evaluate this, we set the first hypothesis as, "based on the level of involvement of the customers, there is a difference between customers' preferences for rewards programs." In the results of Experiment 1 we saw that in a financial compensation program for high-involvement groups and low-involvement groups, significant differences appeared and Hypothesis 1 was partially supported. As for the second hypothesis that "customers will have different preferences between a financial rewards programs (SE) and a joint rewards programs (JE)," the analysis showed that the preference for JE was significantly higher than that for other programs. In addition, through Experiment 2, we were able to find meaningful results, which revealed that consumers have shown a significant difference in their preferences between SE and JE. The purpose of these experiments was to enable the designing of a rewards program by learning how to enhance service information distribution and strengthen customer relationships. From the results, there should be a great amount of value for future service-related endeavors and academic research programs. The research is significant, because the results can be found to have a positive effect on reward program designs however, it does have the following limitations. First, this study was performed using an experiment, and all experiments have limitations. Second, although there was an individual evaluation and a joint evaluation, setting a proper evaluation criteria was difficult. In this study, 1,000 Korean won (KRW) in the individual evaluation had a value of 2 points, and, in the joint evaluation, 1,000 KRW had a value of 1 point. There may have been alternative ways to differentiate the evaluations to obtain the proper results. In this study, since there was no funding, the experiments were performed orally however, this was complementary to the study. Third, the subjects who participated in this experiment were students. Conducting this study through experimentation was unavoidable for us, and future research should be conducted using an actual program with the target customers.

  • PDF

Effects of the Mixture of Vitamin C, Vitamin E, Pycnogenol and Evening Primrose Oil on the UV-Induced Pigmentation and Wrinkle Reductions in Human Skin (비타민과 불포화지방산, 그리고 피크노제놀을 함유한 복합제제의 주름 완화 및 자외선에 의한 색소침착 개선 효과)

  • Chang, Min-Youl;Park, Sang-Ki;Kwak, Taek-Jong;Park, Hyoung-Kook;Lee, Cheon-Koo;Lee, Heon-Sik;Ly, Sun-Yung;Kim, Seong-Jin
    • Journal of Nutrition and Health
    • /
    • v.42 no.6
    • /
    • pp.516-522
    • /
    • 2009
  • In this study, the effects of a mixture consisting of vitamin E, vitamin C, pycnogenol and evening primrose oil (mixture LGNC-5) on ultraviolet light (UV) induced pigmentation and wrinkle reductions of normal healthy volunteers were studied. In a double-blind placebo-controlled study, each of 54 subjects took daily either 4 capsules of the mixture LGNC-5 (Group ABC; 282.5 mg/capsule) or placebo (Group Ganada). We irradiated 2.5 MED UV on the upper arms and measured the whitening effect by colorimeter-based L value. The level of wrinkle reduction was determined by image analysis using skin replica around the crow' feet, and the level of serum vitamin E was determined at baseline and 12 weeks. After 12-week oral administration, the treated group showed a significant reduction in skin pigmentation and wrinkles compared with the placebo group (p = 0.011 and p = 0.000005, respectively). Also, the level of serum vitamin E was significantly increased in the treated group after 12-week oral adminstration of the mixture compared with that in the placebo group (p = 0.0001). In conclusion, 12-week oral administration of LGNC-5 as a dietary supplement could be effective to reduce both UV induced pigmentation and skin wrinkle without side effects.

Electrospun Silk Nano-Fiber Combined with Nano-Hydoxyapatite Graft for the Rabbit Calvarial Model (토끼 두개골 결손부에서 전기 방사된 나노실크-수산화인회석 복합체를 이용한 골재생 효과에 대한 연구)

  • Kye, Jun-Young;Kim, Seong-Gon;Kim, Min-Keun;Kwon, Kwang-Jun;Park, Young-Wook;Kim, Jwa-Young;Lee, Min-Jung;Park, Young-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.293-298
    • /
    • 2010
  • Purpose: The objective of the present study was to determine the capability of electrospun silk fibroin as a biomaterial template for bone formation when mixed with nano-hydoxyapatite in vivo. Materials and Methods: Ten New Zealand white rabbits were used for this study and bilateral round shaped defects were formed in the parietal bone (diameter: 8.0 mm). The electrospun silk fibroin was coated by nano-hydroxyapatite and grafted into the right parietal bone (experimental group). The left side (control group) did not receive a graft. The animals were sacrificed at 6 weeks and 12 weeks, humanly. The microcomputerized tomogram (${\mu}CT$) was taken for each specimen. Subsequently, they were undergone decalcification and stained for the histological analysis. Results: The average value of all measured variables was higher in the experimental group than in the control at 6 weeks after the operation. BMC in the experimental group at 6 weeks after operation was $48.94{\pm}19.25$ and that in the control was $26.17{\pm}16.40$ (P = 0.027). BMD in the experimental group at 6 weeks after operation was $324.59{\pm}165.24$ and that in the control was $173.03{\pm}120.30$ (P = 0.044). TMC in the experimental group at 6 weeks after operation was $19.50{\pm}6.00$ and that in the control was $10.52{\pm}6.20$ (P = 0.011). TMD in the experimental group at 6 weeks after operation was $508.88{\pm}297.57$ and that in the control was $273.54{\pm}175.91$ (P = 0.06). Gross image of both groups showed higher calcification area at 12 weeks than them in 6 weeks. The average value of ${\mu}CT$ analysis was higher at 12 weeks than that in 6 weeks in both groups. BMC in the experimental group at 12 weeks after operation was $51.21{\pm}8.81$ and that in the control was $33.47{\pm}11.13$ (P = 0.010). BMD in the experimental group at 12 weeks after operation was $323.39{\pm}21.54$ and that in the control was $197.75{\pm}76.23$ (P = 0.012). TMC in the experimental group at 12 weeks after operation was $21.44{\pm}5.30$ and that in the control was $13.31{\pm}4.17$ (P = 0.008). TMD in the experimental group at 12 weeks after operation was $524.47{\pm}19.37$ and that in the control was $299.60{\pm}136.20$ (P = 0.016). Conclusion: The rabbit calvarial defect could be successfully repaired by electrospun silk nano-fiber combined with nano-hydroxyapatite.

Availability and Reproducibility Evaluation of High-dose-rate Intraluminal Brachytherapy for Unresectable Recurrent Cholangiocarcinoma (재발한 간담도암 환자에서 시행 한 high-dose-rate intraluminal brachytherapy의 유용성 및 재현성 평가)

  • Park, Ju-Kyeong;Lee, Seung-Hun;Cha, Seok-Yong;Kim, Yang-Su;Lee, Sun-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • General treatment for cholangiocarcinoma is complete surgical resection. However recurrence is common in those patients. In most of cases the purpose of the treatment for patients with recurrent is palliative. Therefore we adopt intraluminal catheter to treat a recurrent patient with high-dose-rate intraluminal brachytherapy. This study aims to evaluate the treatment procedure and set-up reproducibility of intraluminal brachytherapy in the recurrent patient. Study patient was diagnosed at rcT1N0M0 and undergone intraluminal brachytherapy after Arrow Sheath insertion. 3 Gy was delivered in every fraction with a total dose of 30 Gy. We planned dose normalization at distal, proximal and central axis point of narrowed bile duct far from 1 cm. To evaluate set-up reproducibility, we measured distance between distal, proximal treatment target volume point and anterior surface of the thoracic vertebral body respectively for five times before every treatment with dummy seed insertion. Mean distance between distal, proximal treatment target volume point and anterior surface of 10th and 11th thoracic vertebral bodies is 0.5 cm, 6.1 cm and standard deviation is 0.06, 0.08 respectively. In addition, set-up reproducibility was maintained significantly. The patient has been alive with no evidence of disease recurrence for more than a year and has not yet reported severe complications. In conclusion, high-dose-rate intraluminal brachytherapy for unresectable recurrence of cholangiocarcinoma maintains high set-up reproducibility without severe side effects.

Study on the Usefulness about Molecular Breast Imaging In Dense Breast (치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰)

  • Baek, Song Ee;Kang, Chun Goo;Lee, Han Wool;Park, Min Soo;Choi, Young Sook;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

  • PDF

Application of geophysical exploration methods for safety diagnosis of the basement of stone pagoda (지구물리탐사 방법의 석탑지반 안전진단에의 적용)

  • Suh, Man-Cheol;Oh, Jin-Yong;Kim, Ki-Hyun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.70-83
    • /
    • 2004
  • The safety diagnosis of cultural assets is Primarily focused on its non-destructiveness. Research on the nondestructive diagnosis and conservation of masonry cultural heritage is the key which is considered by technologic kernel. Geophyscial Prospecting as nondestructive diagnostic technology plays an important role in the characterization of the foundation of stone pagodas. It is natural that understanding of shallow subsurface condition beneath them is essential for their structural safety diagnosis. As an example, the nondestructive geophysical methods were applied to two three-story stone pagodas, Seokgatap (height 10.8 m, width 4.4 m, weight 82.3 ton) and Dabotap (height 10.4 m, width 7.4 m, weight 123.2 ton) which were built in 791 at Bulkuksa temple. An earlier archaeological investigation shows that stone pagodas have experienced severe weathering process and are slightly leaning, which will threaten their stability At the base part of Dabotap, an offset of the stone alignment is also observed. Direct measurements of ultrasonic velocities was introduced for the mechanical properties of the stone The velocity ranges of ultrasonic waves for Dabotap and Seokgatap are 1217${\~}$4403 m/s and 584${\~}$5845 m/s, respectively, and the estimated averages of the uniaxial compressive strength are 463 kg/$cm^2$ and 409 kg/$cm^2$, respectively. Site characteristics, around the pagodas are determined by the measurement of multiple properties such as seismic velocity, resistivity, image of ground-penetrating radar, On the basis of the higher velocity structure, the site of Seokgatap appears to have solider stability than the Seokgatap site. Near the pagodas, higher(up to 2200 $\Omega$m) resistivity is present whereas their outskirts have as low as 200 $\Omega$m. By the combined results of each geophyscial methods, the subsurface boundaries of two stone pagodas are revealed. The Dabotap site is in the form of an octagon having 6-m-long side with the depth of ${\~}$4 m, whereas the Seokgatap site is the 8 ${\times}$ 10 m rectangle with the depth of 3 m. These subsurface structures appear to reflect the original foundations constructed against the stone load of ${\~}8 ton/m^2$. At the subsurface beneath the northeast of each pagoda, low seismic velocity as well as low resistivity is prominent. It is interpreted to represent the weak underground condition which Is the possible cause of the slightly leaning pagodas toward the NNW.

  • PDF

Usefulness of applying Macro for Brain SPECT Processing (Brain SPECT Processing에 있어서 Macro Program 사용의 유용성)

  • Kim, Gye-Hwan;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyeon-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Diagnostic and functional imaging softwares in Nuclear Medicine have been developed significantly. But, there are some limitations which like take a lot of time. In this article, we introduced that the basic concept of macro to help understanding macro and its application to Brain SPECT processing. We adopted macro software to SPM processing and PACS verify processing of Brain SPECT processing. Materials and Methods: In Brain SPECT, we choose SPM processing and two PACS works which have large portion of a work. SPM is the software package to analyze neuroimaging data. And purpose of SPM is quantitative analysis between groups. Results are made by complicated process such as realignment, normalization, smoothing and mapping. We made this process to be more simple by using macro program. After sending image to PACS, we directly input coordinates of mouse using simple macro program for processes of color mapping, adjustment of gray scale, copy, cut and match. So we compared time for making result by hand with making result by macro program. Finally, we got results by applying times to number of studies in 2007. Results: In 2007, the number of SPM studies were 115 and the number of PACS studies were 834 according to Diamox study. It was taken 10 to 15 minutes for SPM work by hand according to expertness and 5 minutes and a half was uniformly needed using Macro. After applying needed time to the number of studies, we calculated an average time per a year. When using SPM work by hand according to expertness, 1150 to 1725 minutes (19 to 29 hours) were needed and 632 seconds (11 hours) were needed for using Macro. When using PACS work by hand, 2 to 3 minutes were needed and for using Macro, 45 seconds were needed. After applying theses time to the number of studies, when working by hand, 1668 to 2502 minutes (28 to 42 hours) were needed and for using Macro, 625 minutes (10 hours) were needed. Following by these results, it was shown that 1043 to 1877 (17 to 31 hours were saved. Therefore, we could save 45 to 63% for SPM, 62 to 75% for PACS work and 55 to 70% for total brain SPECT processing in 2007. Conclusions: On the basis of the number of studies, there was significant time saved when we applied Macro to brain SPECT processing and also it was shown that even though work is taken a little time, there is a possibility to save lots of time according to the number of studies. It gives time on technologist's side which makes radiological technologist more concentrate for patients and reduce probability of mistake. Appling Macro to brain SPECT processing helps for both of radiological technologists and patients and contribute to improve quality of hospital service.

  • PDF

Usefulness of Blood Pool Half Body in Three Phase Bone Scan in Patients with R/O Reflex Symphathetic Dystrophy Syndrome (반사성교감신경 이영양증후군 환자의 삼상 골 스캔 시 Half Body 혈액 풀 영상의 적용)

  • Lee, Moo-Seok;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2010
  • Purpose: Three phase bone scan was considered sensitive in Patients with Reflex Symphathetic Dystrophy Syndrome (RSDS). Generally, three phase bone scan in the RSDS patients shows increased uptake of one side extremity joint. But three phase bone scan has been performed with flow, blood pool and delayed scan. We performed blood pool half body scan in order to investigate its usefulness. Materials and Methods: From October 2007 to September 2009, three phase bone scan (flow, blood pool, half body blood pool, delayed) was performed after injection of 750 MBq of $^{99m}Tc$-DPD in diagnosed patients with RSDS (M:F=8:7, R:L=9:6). For quantitative analysis, we obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in the three phase images and compared with the count ratios of shoulders in half body blood pool and delayed images. Results: In flow images, right/left ratios were $1.09{\pm}0.53$. In blood pool images, right/left ratios were $1.13{\pm}0.47$ (hand), $1.08{\pm}0.26$ (shoulder). In delayed images, right/left ratios were $1.24{\pm}0.75$ (hand), $1.11{\pm}0.31$ (shoulder). As a result, Log of right/left counts of the others and that of shoulder blood pool image were correlated well with statistical significance (Spearman's R, p<0.005 SPSS for windows ver.12.0). Conclusion: Half body blood pool scan may be helpful in the diagnosis of patients with RSDS. Moreover, Half body blood pool scan reduced false negative and false positive rates. In order to improve agreement on interpretation of RSDS, Blood pool half body scan should be established as common criteria.

  • PDF

Radiation Exposure Dose Reduction on Upper Gastrointestinal Series (위장조영검사에서 피폭선량 저감)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Upper gastrointestinal series is non-invasive examination, and it is useful for patients or elderly patients who have difficulty in endoscopic examination because of absence of any side effects other than temporary constipation or abdominal pain. The entire image of the gastrointestinal tract can be seen and have been widely used in the diagnosis of upper gastrointestinal diseases. However, there is a possibility that radiation dose increases due to improper movement and breath control, when examination is carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. In upper gastrointestinal series to increase understanding of examination, to induce appropriate cooperation during examination, to reduce the number of retakes and shorten examination time, and to reduce dose of the subject, the procedure and precautions of the gastrointestinal test were made as a movie. We investigated the effectiveness of pre-education using the movie to reduce the inspection time, the number of re-shoots, and the reduction of exposure dose by watching the movie during the waiting time before examination. 120 patients that were selected each 20 patients aged from 30s to 80s were evaluated were evaluated for exposure dose, examination time, and the number of retakes before and after the movie training. The radiation dose, the examination time, and the number of retakes were respectively $3171.83{\mu}Gy{\cdot}m^2$ and $2931.73{\mu}Gy{\cdot}m^2$, 8.05 min, and 6.75 min, and 1.68 times and 1.22 times before and after movie training. It can be concluded that the movie training on the gastrointestinal examination influences the reduction of the examination time, the number of retakes and the reduction of the radiation dose.