• 제목/요약/키워드: Side Wall Angle

검색결과 80건 처리시간 0.029초

Effect of the circle tunnel on induced force distribution around underground rectangular gallery using theoretical approach, experimental test and particle flow code simulation

  • Vahab, Sarfarazi;Reza, Bahrami;Shadman Mohammadi, Bolbanabad;Fariborz, Matinpoor
    • Structural Engineering and Mechanics
    • /
    • 제84권5호
    • /
    • pp.633-649
    • /
    • 2022
  • In this study, the effect of circle tunnel on the force distribution around underground rectangular gallery was investigated using theoretical approach, experimental test and Particle flow code simulation (PFC). Gypsum model with dimension of 1500×1500 mm was built. Tensile strength of material was 1 MPa. Dimension of central gallery was 100 mm×200 mm and diameter of adjacent tunnel in its right side was 20 mm, 40 mm and 60 mm. Horizontal distance between tunnel wall and gallery edge were 25, 50, 75, 100 and 125 mm. using beam theory, the effect of tunnel diameter and distance between tunnel and gallery on the induced force around gallery was analyzed. In the laboratory test, the rate of loading displacement was set to 0.05 millimeter per minute. Also sensitivity analysis has been done. Using PFC2D, interaction between tunnel and gallery was simulated and its results were compared with experimental and theoretical analysis. The results show that the tensile force concentration has maximum value in center of the rectangular space. The tensile force concentration at the right side of the axisymmetric line of gallery has more than its value in the left side of the galleries axisymmetric line. The tensile force concentration was decreased by increasing the distance between tunnel and rectangular space. In whole of the configurations, the angles of micro cracks fluctuated between 75 and 105 degrees, which mean that the variations of tunnel situation have not any influence on the fracture angle.

Dipyridamole 부하 심장 풀 스캔을 이용한 관동맥질환의 평가 (Evaluation of Coronary Artery Disease with Gated Blood Pool Scan Using Dipyridamole)

  • 김광원;최정일;정병천;이재태;이규보;채성철;전재은;박의현;박희명
    • 대한핵의학회지
    • /
    • 제25권1호
    • /
    • pp.27-36
    • /
    • 1991
  • Thirty-one patients with coronary artery disease and twenty-sir normal subjects underwent $^{99m}Tc-GBPS$ before and after coronary vasodilatation was induced by dipyridamle 0.54 mg/kg given IV over 4 min. LVEF, ${\Delta}EF$ and regional wall motion by phase analysis were measured during rest and dipyridamole infusion. The results were as follows: 1) Mean LVEF of normal subjects was significantly higher than that of MI group (p=0.001), but similar to that of angina group during rest. Among MI group, mean LVEF of anterior MI group was significantly lower than that of inferior MI group during rest (p=0.024). 2) The normal subjects had a significaat increase in mean LVEF during dipyridamole infusion $(+12{\pm}3.8)$, while the CAD group had no increase $(+2{\pm}5.0)$ (p<0.001). If an increase of LVEF during stress is less than 5%, it suggests an abnormality. The sensitivity and specificity of LVEF changes after dipyridamole infusion were 81%, 96%, respectively. 3) With phase analysis, LV mean phase angle of normal subjects and CAD patients was $143{\pm}20.5^{\circ},\;132{\pm}20.6^{\circ}$ respectively, durign rest (p=0.049). But an ncrease of LV mean phase angle during dipyridamole infusion in these two groups was not significantly different. Dipyridamole infusion did not affect standard deviation and FWHM of phase angle. 4) Regional wall motion was abnormal in 5 patients (16%) during dipyridamole infusion. 5) Side effects with dipyridamole infusion include; headache, angina pain, chest discomfirt, nausea, weakness sense. In conclusion, dipyridamole GBPS might be useful in detection and follow up of CAD.

  • PDF

패널굴절방식 환기창 온실의 환기효과 (Ventilation Effect of the Greenhouse with Folding Panel Type Windows)

  • 김진영;이시영;김현환;전희;윤익학
    • 생물환경조절학회지
    • /
    • 제11권1호
    • /
    • pp.5-11
    • /
    • 2002
  • 본 연구는 여름 같은 고온기나 외부온도가 높지 않아도 시설내 온도가 많이 상승하는 봄 .가을 같은 시기에 온실내 고온 공기를 외부로 신속하게 유출시켜 강제환기를 사용하지 않고도 온실내부의 환경을 조절 할 수 있는 새로운 자연 환기창을 개발하는데 목적을 두고 수행하였다 패널굴절방식 측창은 지면에 가까운 쪽의 패널 하부에 절점을 두고 패널 상부가 측고 부위로부터 가이드 레일을 따라 하향하도록 구성하여 창이 개방되게 하였고, 천창은 측고 부위에 절점을 두고 용마루 쪽의 패널 상부가 가이드 레일을 따라 경사진 지붕면을 따라 하향하도록 구성하여 고온 공기층이 정체되어 있는 온실 상부인 측고 부위와 용마루 부위가 개방되도록 하였다. 굴절 패널의 상부 개방거리는 X=L(1-cos$\theta$)로 나타낼 수 있고 측면 개방 거리는 Y=L/2$\times$sin$\theta$로 나타낼 수 있다. 천창 개방시간은 4분 20초 소요되었으며 개방 시작한 2분 후부터 온도가 하강하기 시작하였고, 완전 개방 2분 후부터는 외기온과의 온도차 3~4$^{\circ}C$정도를 유지하면서 평형상태를 유지하였다. 패널굴절방식 환기창 온실의 환기성능은 체적환기량이 22.3-94.3m$^3$.m$^{-2}$ .h$^{-1}$이었으며, 환기 횟수는 15.2~39.3회.h$^{-1}$로 나타나 일반적인 연속형 천창의 10~15회.h$^{-1}$ 정도에 비해 환기효과가 높은 것으로 나타났다. 그리고 벤로형 온실과의 천창개폐시 온도하강을 비교하였을 때 환기효과가 2배 이상 높은 것으로 판단되었다.$_{r}$", $\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.加的)으로 되거나 과가황(過加黃)이 될 우려가 있는 제조공정(製造工程)에서는 흔히들 이 방법(方法)을 무시(無視)하고 있다. 여기서 강조(强調)해 두어야 할 것은 항상 제품(製品)의 외부(外部)를 완전(完全)히 가황(加黃)시킬 필요(必要)는 없다는 것이다. 다공성(多孔性)이나 기포생성(氣泡生成)을 조장(助長)하는 불량가황상태(不良加黃狀態)와 표면(表面)에서의 과가황상태간(過加黃狀態間)의 균형(均衡)을 취(取)해 줘야 하는데 물론(勿論) 이때는 가황시간(加黃時間)을 단축(短縮)시켜야 한다는 경제적(經濟的)인 측면(側面)도 아울러 고려(考慮)해야 한다

3차원 수치모의를 이용한 배수갑문의 방류능력 개선효과 분석 (Analysis of the Discharge Capacity Improvement of a Lock Gate by Using 3-Dimensional Numerical Simulation)

  • 김남일;김대근;이길성;김달선
    • 한국수자원학회논문집
    • /
    • 제38권3호
    • /
    • pp.189-198
    • /
    • 2005
  • 본 연구에서는 조력발전소 배수갑문의 형상과 배치에 따른 방류능력을 해석하는데 3차원 수치모의가 효과적으로 이용될 수 있음을 보였다. 3차원 수치모형은 RANS를 지배방정식으로 하는 FLOW-3D 모형을 이용하였다. 본 연구결과 배수갑문의 방류능력은 물받이길이와 도류벽의 접근각도에 큰 영향을 받는 것으로 나타났다. 그리고 이의 개선 여부에 따라 $10\%$ 이상의 방류량 차이가 발생하였다. 또한 방류량은 배수문과 수차구조물을 연결하는 구조물의 형상과 물받이 끝 사면경사의 영향을 받는 것으로 나타났다. 본 연구에서는 배수갑문의 설계시 방류능력 개선을 위해서는 수리학적 검토가 필요하며, 수치모형실험이 수리모형실험과 더불어 유용한 해석도구로 이용될 수 있음을 보였다.

계단형 슬롯출구의 높낮이 변화에 따른 2차원 막냉각 특성 (2-Dimensional Film Cooling Characteristics with the Height Variation of a Stepped Slot Exit)

  • 손창호;김태묵;이근식
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.46-54
    • /
    • 2005
  • Film cooling characteristics has been examined numerically for the height variation of a stepped slot exit. In this study, the upstream wall height of the stepped slot exit varies from -2d (d = slot width) to 3d, blowing ratio ranges from 0.5 to 3, and injection angles are $15^{\circ},\;30^{\circ},\;and\;45^{\circ}$. The results showed that film cooling performance was mainly subjected to the magnitude of recirculation region near the downstream-side slot exit as well as the magnitude and the distribution region of turbulent kinetic energy due to the local velocity and momentum differences between the coolant and the main flow near the slot exit. The up-1d type slot at higher blowing ratios over 2 and the flat type slot at lower blowing ratios below 1 have the best film cooling performances, in case of the injection angles of $30^{\circ},\;and\;45^{\circ}$, respectively. Compared with the other injection angles, in case of the injection angles of $15^{\circ}$, the best film cooling performances was shown in even a higher upstream wall (up-3d) at higher blowing ratio like 3 by the gradual reduction of the coolant velocity which minimizes the local velocity differences between the coolant and the main flow near the slot exit.

단관비계의 구조규격에 관한 연구 (A Study on the Structural Standard of the Tube and Coupler Scaffold)

  • 이영섭
    • 한국안전학회지
    • /
    • 제5권2호
    • /
    • pp.66-75
    • /
    • 1990
  • This study is conducted to establish the structural standard of tube and coupler scaffold which is suitable for our present stuation through the comparison analysis for domestic and foreign standards as well as measurement of field survey. The results of this study are as follows : 1) The load is classified by three categories, light-duty(equal and lower than 150kg/m$^2$), medium-duty(150-250 kg/m$^2$), heavy-duty(250-350kg/m$^2$), and the equivalent horizontal length of side posts is each, 1.5-1.8m, 1.2-1.5m, equal and lower than 1.2m, and the equivalent horizontal length between front and rear posts is each 1.2-1.5m, 0.9-1.2m, equal and lower thatn 0.9m, in accordance with the load classification. 2) The height between upper and lower runner is equal and lower than 1.5m, and the brace across the width of scaffold should be installed within 15m in horizontal direction at 45 degree angle. 3) The entire scaffold should be securely tied to the wall of permanent structure with uslng anchor and bolt at intervals not to exceed 6m in case of non-connection and 4.5m in case of connection in both horizontal and vertical direction. 4) The post should be installed on the sound foundation tied to lumber footing with using base plate, and standard platform plank should be produced in the factory and widely used in the construction field.

  • PDF

마이크로 채널 내 유도-전하 전기삼투에 의한 혼합 (Mixing in a Microchannel by using Induced-charge Electro-osmosis)

  • 전영훈;허영근;정원혁;수레수 알라파티;서용권
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents an experimental study on the performance of a micro-mixer using AC electro-osmotic flow. The microchannel is made of PDMS for the side and top walls and glass patterned with ITO for the bottom wall. We first investigated the effect of the applied potential as well as the frequency on the slip velocity. We have found that the slip velocity is roughly proportional to the applied voltage in line with the Helmholtz-Smoluchowski equation and there is an optimum frequency at which the slip velocity becomes maximized. To find the optimum parameters for mixing device we tested our device for various design parameters. It turned out that the best mixing effect is obtained approximately when the electrode angle is $30^{\circ}$, electrode width $200\;{\mu}m$, and the frequency of power supply 700 Hz.

차량 롤전복의 과도거동에 관한 시험적 연구 (An Experimental Study on the Transient Behavior of Vehicle Rollover)

  • 이명수;김상섭
    • 한국자동차공학회논문집
    • /
    • 제19권3호
    • /
    • pp.113-121
    • /
    • 2011
  • Rollover accident is one of the serious traffic accident and rollover accident takes high portion of all accident. The most common type of rollover is a tripped rollover which occupy 95% of all type of single-vehicle rollover. Tripped rollover occurs when a vehicle leaves normal road way and tripped by loose gravel, soil of fixed object such as guard rail, curbs and ditches. And the rest of the type of rollover is un-tripped rollover. An un-tripped rollovers that occurs during high-speed collision avoidance maneuvers. In this paper, presents the explanation of the un-tripped rollover test method and procedure, additionally this paper deals with various occurrence in the un-tripped test such as occurring excessive tire camber in the un-tripped test, tire side-wall contact with road surface and roll oscillation. And this paper analyzes the analysis of the roll rate amplitude in specific frequency through the FFT (Fast Fourier Transform) and the roll angle at the steering reverse timing which is the Fishhook test roll rate feedback time. Finally, this paper analyzes the relations between the estimated steady state roll gain and rollover stability.

깔때기 경사충격파를 고려한 환형 분사 초음속 이젝터 이론해석 (Theoretical Analysis of Annular Injection Supersonic Ejector with a Simple Funnel Shock Wave Model)

  • 김세훈;권세진
    • 한국추진공학회지
    • /
    • 제10권1호
    • /
    • pp.23-29
    • /
    • 2006
  • 환형 분사 초음속 이젝터에서는 초음속의 주유동이 벽면을 타고 분사되므로 주유동 노즐 출구(혼합 챔버 입구)에서 혼합챔버의 수축각에 의한 깔때기(funnel) 모양의 경사충격파가 발생한다. 본 연구에서는 이차원(Wedge) 경사충격파와 원뿔(Cone) 경사충격파를 이용하여 간단한 깔때기 경사충격파 모델링(Modeling)을 수행하였다. 이러한 모델링을 이용하여 기존의 이차원 경사충격파를 이용한 이론해석 보다 부유동 압력을 보다 정확히 예측할 수 있었다. 같은 해석 방법을 이용하여 유량비에 대한 초음속 이젝터의 압축비와 단열 효율을 얻을 수 있었다.

Si(100)기판위에 성장된 3C-SiC 박막의 반응성 이온식각 특성 (Reactive Ion Etching Characteristics of 3C-SiC Grown on Si Wafers)

  • 정귀상;정수용
    • 한국전기전자재료학회논문지
    • /
    • 제17권7호
    • /
    • pp.724-728
    • /
    • 2004
  • This paper describes on RIE(Reactive Ion Etching) characteristics of 3C-SiC(Silicon Carbide) grown on Si(100) wafers. In this work, CHF$_3$ gas was used to form the polymer as a function of a side-wall for excellent anisotropy etching during the RIE process. The ranges of the etch rate were obtained from 60 $\AA$/min to 980 $\AA$/min according to the conditions such as working gas pressure, RF power, distance between electrodes and the $O_2$ addition ratio in working gas pressure. Under the condition such as 100 mTorr of working gas pressure, 200 W of RF power and 30 mm of the distance between electrodes, mesa structures with about 40 of the etch angle were formed, and the vertical structures could be improved with 50 % of $O_2$ addition ratio in reactive gas during the RIE process. As a result of the investigation, we know that it is possible to apply the RIE process of 3C-SiC using CHF$_3$ for the development of electronic parts and MEMS applications in harsh environments.