• Title/Summary/Keyword: Shut-off device

Search Result 14, Processing Time 0.018 seconds

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF

Study on Divice for the Automatic Shut Off of Equipment Stand-by Power (자동전원 계폐장치에 관한 연구)

  • Kim, H.K.;Hyun, K.W.;Bae, J.I.;Yang, S.Y.;Park, S.T.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2626-2627
    • /
    • 1999
  • The device we have developed is the automatic shut off equipment which will reduce energy consumption when an equipment is in stand by power state. The principle for this system is when a man is moving, electricity will flow by setting a on-off light system. At night, in the stand-by power state the electric supply will be shut off immediately which will reduce energy consumption. Energy consumed by 24hour operating machines and stand-by electronic devices will be reduced by pulse signals which will give power supply when needed.

  • PDF

Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility (고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석)

  • Kim, Myung-Chul;Woo, Jeong-Jae;Lee, Hyung-Sub;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

Implementation of Smart Multi-tap System based on Zigbee Communication (Zigbee 통신 기반 스마트 멀티탭 시스템 구현)

  • Lee, Jung-Hyuck;Kim, Sang-Hyun;Oh, Chang-Se;Seo, Min-Seok;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.930-936
    • /
    • 2014
  • Smart Multiple-Tap to be introduced in this paper, is an electronic device that controls the Multibple-Tap through the Smartphone. It runs on network and has an inbuilt Zigbee communication module. Thus, users can control home devices from remote through home server. Mentioned home server is operated as a gateway and is connected with smart devices on the Internet. To sum up, Users using this Smart Multiple-Tap can check the state information of the multi-tap ON/OFF and can control immediately by smartphone. also, Smart Multiple-Tap perfectly shut down the standby power. when users turn off each of the Smart Multiple-Tap's circle, It drives automatically lowest electricity-consuming mode and shut down the standby power by its own built-in SSR module. therefore, it will bring the energy saving effect on environment using Smart Multiple-Tap.

A FPGA Development for the Fail Safe Control of TMR System (TMR시스템의 고장안전제어를 위한 FPGA 개발)

  • 강민수;이정석;김현기;유광균;이기서
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.336-343
    • /
    • 2000
  • This paper proposes the failsafe control logic. which has applied to the voting on the TMR system by using FPGA The self-detection circuit is also designed for detecting a characteristic of fault at TMR system. The fault producing in the self-detection system is largely classified among an intermittent fault, a transient fault and a permanent fault. If it is happened to the permanent fault, the system can be failed. Therefore, it is designed the logic circuit which is not transferred the permanent fault to the system after shut off output. The control logic of the Fail Safe proposed in the paper is required for a circuit integrate of device to minimize the failure happened. Therefore, it makes to design FPGA with modeling of VHDL. The circuit of the Fail Safe of TMR system is able to apply to nuclear system, rail-way system, aerospace and aircraft system which is required for high reliability.

  • PDF

Field Empirical Result Analysis According to the Operation Reliability Test of the Wireless Gas Shut-off Device (무선가스 차단 장치 동작 신뢰성 시험에 따른 현장 실증 결과분석)

  • Hwang, Do-Yeon;Lee, Kyung-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.70-77
    • /
    • 2021
  • As IoT technology develops along with the 4th industrial revolution, gas safety products to which IoT technology is applied are being developed. However, since the gas safety system was not allowed, system improvement and operation reliability test for IoT gas safety products are required. This thesis researches IoT fuse cock and smart multi-function meter among IoT gas safety products, and analyzes the empirical data of IoT fuse cock to secure operational reliability data, thereby becoming a leader in IoT gas safety products. It aims to develop gas barrier technology one step further through various test evaluations and methods in the future.

Home Energy Management System for Interconnecting and Sensing of Electric Appliances

  • Cho, Wei-Ting;Lai, Chin-Feng;Huang, Yueh-Min;Lee, Wei-Tsong;Huang, Sing-Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.7
    • /
    • pp.1274-1292
    • /
    • 2011
  • Due to the variety of household electric devices and different power consumption habits of consumers at present, general home energy management (HEM) systems suffer from the lack of dynamic identification of various household appliances and a unidirectional information display. This study presented a set of intelligent interconnection network systems for electric appliances, which can measure the power consumption of household appliances through a current sensing device based on OSGi platform. The system establishes the characteristics and categories of related electric appliances, and searches the corresponding cluster data and eliminates noise for recognition functionality and error detection mechanism of electric appliances by applying the clustering algorithm. The system also integrates household appliance control network services so as to control them according to users' power consumption plans or through mobile devices, thus realizing a bidirectional monitoring service. When the system detects an abnormal operating state, it can automatically shut off electric appliances to avoid accidents. In practical tests, the system reached a recognition rate of 95%, and could successfully control general household appliances through the ZigBee network.

A Study on the Seal Life Improvement of the Hydraulic Servo Actuator for Steam Control of Power Plants (발전소 스팀제어용 유압서보 액추에이터의 씰 수명 향상에 관한 연구)

  • Lee, Yong Bum;Lee, Jong Jik
    • Journal of Drive and Control
    • /
    • v.15 no.2
    • /
    • pp.32-37
    • /
    • 2018
  • The power plants use turbine output control devices to supply or shut off steam to high pressure and low-pressure steam turbines connected to generators. This turbine output control device is driven by a hydraulic servo actuator. The gas flows into the hydraulic servo actuator during periodic inspection or normal operation, and the resulting adiabatic compression of the gas raises the internal temperature of the actuator to $500^{\circ}C$. This temperature increase causes the seals to burn and show wear and tear, resulting in failure. In this study, an air vent valve was installed to allow gas inside the hydraulic servo actuator to flow large quantities of air at the beginning of the operation and after the periodic inspection. Gas was passed through for only minute flow during normal operation of the power plant. By applying the air vent valve, it improves the reliability of the hydraulic servo actuator by discharge the gas appropriately to improve the life of the seal.

Safety Schematic Diagram and Sequence of Heater in FPD Wet Equipment (FPD 장비 습식공정에서의 안전한 히터 공급 계통도 및 제어 회로)

  • Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.107-111
    • /
    • 2019
  • In FPD WET equipment, heaters are used a lot. There are many electric accidents caused by short circuit and overheating due to the use of heater, so it is necessary to have a safe electric system and interlock. Therefore, in this paper, we propose an electrical schematic and interlock for FPD WET equipment. In this paper, a hardware interlock such as a level sensor, an overheat protector, and an SSR heater sink is inserted, and the electric system is composed of ELB - MC - SSR - EOCR - heater. When the interlock occurs, the magnetic contactor (MC) is turned off and the power of the heater is cut off.EOCR, an electric overcurrent protection device, has an interlock to shut down the MC when there is an abnormality in the heater while checking the overcurrent, undercurrent and disconnection. These circuit configurations and interlocks are likely to be useful not only for WET equipment but also for any equipment in which the heater is placed.