• Title/Summary/Keyword: Shrinkage

Search Result 3,280, Processing Time 0.032 seconds

Shrinkage Stress Analysis of Concrete Slab with Shrinkage Strip in Multi-Story Building (수축대를 사용한 고층건물 콘크리트 슬래브의 건조수축응력 해석)

  • 김한수;조석희
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.726-733
    • /
    • 2002
  • Shrinkage strip or separation strip is a temporary joint that is left open for a certain time during construction to allow a significant part of the shrinkage to take place without inducing stress. A shrinkage stress analysis method of shrinkage strip in concrete slab of multi-story building considering the relaxation effect of creep and construction sequence is proposed. The analysis results of 10-story example building show that the effect of shrinkage strip can be analyzed easily by the proposed method. And shrinkage strip installed in a particular floor makes the stress of that floor reduced and the stress of the other floors increased a little. The rate and amount of stress reduced with closing time mainly depends on the development of shrinkage with time of concrete model used. The amount of stress reduced is determined by the amount of shrinkage strain developed before the closing of shrinkage strip.

Performance Improvement of High Performance Shrinkage Reducing Agent using Early Strength Improving Agent (조기강도 개선제를 활용한 고성능 수축저감제의 성능 개선)

  • Park, Jong-Pil;Jung, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.296-302
    • /
    • 2016
  • Studies aimed at reducing the occurrence of cracks by the shrinkage of concrete are in demand because the repair and reinforcement for cracks caused by declining concrete durability costs the user to maintain the concrete structure. In particular, in underground power facilities for power transmission, the cost is a heavy burden to repair and reinforce. For this reason, underground power facilities demanded effective methods for crack reduction at the engineering design step. This study, as a part of the development of shrinkage reducing agent for low shrinkage concrete on underground power facilities, investigated TEA to complement the shrinkage reducing agent to improve the early strength of concrete. In the case of TEA 3% as a shrinkage reducing agent, the early strength was improved significantly, and the shrinkage reducing effect was excellent. In addition, TEA 3.0 % and the shrinkage reducing agent 2.0 % showed excellent shrinkage property and compressive strength. On the other hand, more study of shrinkage reducing materials, including performance reviews on the shrinkage reducing materials with variable factors and type of materials, will be needed to generalize these results.

A STUDY OF CONTRACTION SHRINKAGE OF COMPOSITE RESINS AND ORMOCERS WITH VARIOUS CURING TIMES (광조사 시간에 따른 복합레진과 Ormocer의 중합수축에 관한 연구)

  • Chung, Yeon-Chung;Min, Kyung-San;Lee, Hae-Hyoung;Cho, Kyung-Mo;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.326-333
    • /
    • 2003
  • Ormocer has organic-inorganic compound polymers. One of advantages of ormocer is reduced polymerization shrinkage. The purpose of this study was to compare the amount of contraction shrinkage of composite resins and ormocers. Additionally, the time of each material when there is no further change of contraction shrinkage was analysed. Four brands of composite resins (P-60. Surefil, Z-250 and Denfil) and two brands of ormocers (Definite and Admira) were used. 20 seconds, 40 seconds and 60 seconds of curing times were given. Contraction shrinkage of them were measured using a linometer for 80 seconds. The effect of material and curing time to contraction shrinkage at the time of 80 seconds was analysed by two-way ANOVA. The effect of time to contraction shrinkage was analysed by one-way ANOVA and the time when there was no further change of the contraction shrinkage was analysed. The results are as follows: 1. P-60, Definite, Z-250 and Denfil had no further change of contraction shrinkage from the time of 20 seconds, and Surefil and Admira had no further change of contraction shrinkage from the time of 10 seconds. 2. Statistical analysis revealed volumetric shrinkage varied among material (p<0,05). No significant difference of contraction shrinkage among different curing times was found, and there was no effect of interaction between materials and curing times to contraction shrinkage. 3. Definite and Admira showed the statistically same contraction shrinkage with those of Z-250 and P-60. which is higher than that of Surefil and lower than that of Denfil (p<0.05).

THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES (점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향)

  • Lee, In-Bog;Son, Ho-Hyun;Kwon, Hyuk-Chun;Um, Chung-Moon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.457-466
    • /
    • 2003
  • The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

Shrinkage Properties of High Performance Concrete Used Expansive Additive and Shrinkage Reducing Agent (팽창재와 수축저감제를 사용한 고성능 콘크리트의 수축 특성)

  • Koh, Kyung Taek;Park, Jung Jun;Ryu, Gum Sung;Kang, Su Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.787-794
    • /
    • 2006
  • Generally, high performance concrete has characteristics such as low water-cementitious material ratio, lots of unit binder powder, thus the heat of hydration, autogenous shrinkage are tend to be increased. This study is to investigated the effect of the expansive additive and shrinkage reducing agent on the shrinkage properties of high performance concrete as a study to develop the reduction technology of the concrete shrinkage. Test results showed that the expansive additive and shrinkage reducing agent were effective the reduction of shrinkage of high performance concrete. Especially, the using method in combination with expansive additive and shrinkage reducing agent was more effective than the separately using method of that. Also, it analyzed that the combination of expansive additive of 5% and shrinkage reducing agent of 1% was the most suitable mixture, considering to the fluidity, strength and shrinkage properties.

A Study on Modelling for Prediction of Concrete Drying Shrinkage according to Aggregate Ratio of Concrete (잔골재율 변화에 따른 콘크리트 건조수축 모델링에 관한 연구)

  • Park, Do-kyong;Yoon, Yer-Wan;Kim, Kwang-Seo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.4
    • /
    • pp.71-77
    • /
    • 2004
  • Drying Shrinkage has much complexity as it has relations with both internal elements of concrete and external factors. Therefore, experiments on Concrete Drying Shrinkage are carried out in this study under simplified circumstances applying temperature & Humidity test chamber which enables constant temperature and humidity. Comparative analyses have been made respectively according to the consequences aiming at modelling for prediction of Concrete Drying Shrinkage and making out measures to reduce it. Strain Rate of Drying Shrinkage of concrete under the condition of dry air appears to rise by about 20%-30% in proportion as the temperature rises $5^{\circ}C$ when the humidity was held below 10% compared under the condition of dry temperature & Humidity test chamber. Strain Rate of Drying Shrinkage in pit sand concrete increased 20% higher than measured when in river sand under the condition of 90-day material age. A general formula with two variables is derived as follow ${\varepsilon}={\alpha}_1+{\beta}_1x_1+{\beta}_2x_2+{\beta}_3x_1^2+{\beta}_5x_2^2$. and also graphed in 3 dimensions, enabling to apply to actual design and predict Strain Rate of Drying Shrinkage in concrete. The results of prediction of Rate of Drying Shrinkage by Response Surface Analysis are as follows. The coefficient of correlation of Drying Shrinkage in Concrete was over 90%.

Physical Properties and Drying Shrinkage of Concrete Using Shrinkage Reducing Admixtures (수축저감제를 사용한 콘크리트의 물성변화 및 건조수축 저감 특성)

  • Han, Cheon-Goo;Song, Seung-Heon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.101-107
    • /
    • 2005
  • This paper reports the contribution of Shrinkage reducing admixture(SRA) to the physical properties and drying shrinkage of concrete. Dosage of SRA is varied with. For the properties of fresh concrete, an increase in SRA dosage results in a decrease in fluidity and air content, while setting time is accelerated. For the properties of hardened concrete, the incorporation of mineral admixture leads to a decrease in compressive strength at early age, whereas after 28 days, the incorporation of fly ash(FA) and blast furnace slag(BS) has greater compressive strength than conventional concrete without admixture. The use of SRA results in a decrease in compressive strength. The incorporation of SRA with every $1\%$ increase causes the decrease of compressive strength by as much as $3\~6\%$. For drying shrinkage properties, the incorporation of FA and BS reduces drying shrinkage slightly. The use of SRA also decreases drying shrinkage. Every $1\%$ of increase in SRA dosage can reduce drying shrinkage by as much as $10\~15\%$

The Behavior of Shrinkage on PMMA in Injection Compression Molding (사출압축성형시 PMMA 재료의 성형수축거동)

  • Choi Y.S.;Kang C.M.;Jeong Y.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.589-592
    • /
    • 2005
  • Molding shrinkage s variation is one of the problems to be solved in conventional injection molding. Despite many trying-out has been to solve these, intrinsic causes of shrinkage such as orientation and thermal exchange between melt and mold has yet not solved. For reducing shrinkage and residual stress on molding, injection compression molding process was invented. In this study, experiments about effect of injection compression molding's parameters on shrinkage of molding were conducted with PMMA and compared with conventional injection molding's shrinkage. Before the injection compression molding experiment, molding shrinkage rate was predicted by analyzing pvT graph and was compared with the results of experiment. The shrinkage rate of injection compression molding was lower than convention injection molding' one but was different from the predicted shrinkage. The reason was observed that experiment mold as not positive type, flowing backward of melt into nozzle and unreasonable mechanism of injection molding machine.

  • PDF

A Study on Modelling for Prediction of Concrete Drying Shrinkage according to Properties of Aggregate (잔골재 특성에 따른 콘크리트 건조수축 모델링에 관한 연구)

  • Park Do-Kyong;Yang Keek-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.73-77
    • /
    • 2006
  • Drying Shrinkage has much complexity as it has relations with both internal elements of concrete and external factors. Therefore, experiments on Concrete Drying Shrinkage are carried out in this study under simplified circumstances applying temperature & Humidity test chamber which enables constant temperature and humidify. Comparative analyses have been made respectively according to the consequences aiming at modelling for prediction of Concrete Drying Shrinkage and making out measures to reduce it. As a result Strain Rate of Drying Shrinkage of concrete was measured to increase by average $10{\times}10^{-5}$ in proportion to additional 4% increase in fine aggregate ratio, when water/cement ratio constant. Strain Rate of Drying Shrinkage in pit sand concrete increased 20% higher than measured when in river sand under the condition of 90-day material age. 6. Strain Rate of Drying Shrinkage in sea sand concrete increased $10%{\sim}15%$ higher than measured when in river sand. The results of prediction of Rate of Drying Shrinkage by Response Surface Analysis are as fellows. The coefficient of correlation of Drying Shrinkage in concrete was over 90%.

Shrinkage of Knitted Fabric Depending on the Condition of Air Drying (자연 건조 조건에 따른 니트 소재 수축)

  • Ju, Jeongah;Kyung, Moonsoo;Kim, Jeehoon;Park, Yongwan;Kim, Sangyoung;Oh, Youngkee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.6
    • /
    • pp.1050-1059
    • /
    • 2017
  • Drying processes often cause knitted fabrics to shrink. This study obtains proper drying conditions for in the dryer use that can minimize knitted fabric shrinkage by investigating changes in shrinkage according to drying conditions. The experiment samples were all machine washable plain, mesh, and lacoste knitted fabrics made of 100% cotton. Samples were first washed in a washing machine on a normal cycle. They were then layered on a flat surface in an artificial climate chamber and dried for 24 hours at $20^{\circ}C$ and $40^{\circ}C$, respectively. Shrinkage was measured for 180 minutes at 30 minute intervals after washing. The comparison results of the shrinkage in the washing and drying process indicate that 80.0% and 23.0% shrinkage of plain knitted and lacoste knitted fabrics occurred during the washing process. As the samples dried, the shrinkage of the plain and lacoste knitted fabrics then rapidly increased after approximately 30.0% moisture content. The highest air drying shrinkage occurred over one cycle with insignificant changes in shrinkage after repeated treatments.