• 제목/요약/키워드: Shoulder range of motion

검색결과 584건 처리시간 0.02초

한국 대학생의 가상 hip 관절과 하지관절의 동작범위 측정 (Measurement on range of virtual hip and lower limb joints for young male students)

  • 기도형
    • 대한인간공학회지
    • /
    • 제15권2호
    • /
    • pp.125-135
    • /
    • 1996
  • The purpose of this research is to measure range of virtual hip joint and lower limb joints motion such as the hip, knee and ankle joints for 47 young male students. The results of ANOVA revealed that anthropometric dimensions including weight and stature did not show any significant effects on the range of virtual hip joint and lower limb joints motion and the range of motion with two degrees of freedom at the shoulder, virtual hip and hip joints. Anthropometric dimensions such as age, weight, statuire, arm length, shoulder height and leg length were found to be lowly correlated with the range of virtual hip joint and lower limb joints motion. It is expected that the data on the range of joint motion suggested in this study can be used as a valuable input data when designing workplace, predicting human posture and reach volume, etc.

  • PDF

스마트폰 중독 잠재위험군의 어깨 기울기, 목 관절가동범위 및 주관적 통증 정도의 상관관계 (Correlation Between Shoulder Gradient, Range of Motion of the Neck, and Subjective Pain level of the Potential Risk Group of Smart-phone Addiction)

  • 정연우
    • 대한통합의학회지
    • /
    • 제5권2호
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose : The purpose of this study was to investigate the correlation between shoulder gradient, range of motion of the neck, and subjective pain level of the potential risk group of smart-phone addiction. Methods : The subjects of this study were 90 women's who had potential risk of smart-phone addiction. VAS was used to measure subjectively pain intensity. Global Postural System was used to measure forward head posture. CROM was used to measure flexion, extension, lateral flexion of cervical range of motion. Results : The results of this study showed that was significant positive correlation between the both shoulder gradient, and cervical range of motion(p<.05). Statistically significant negative correlation between the VAS and left lateral flexion(p<.05). Conclusions : The difference between the gradient of both shoulders increased with the use of smart-phone addiction, and the cervical left lateral flexion decreased as the pain increased. This suggests that recognition on decrease of using smart phone and postural correction is necessary.

Smovey 운동이 유방암 절제술을 한 여성의 견관절 관절가동범 위, 통증, 기능수준, 근력에 미치는 영향 (The Smovey Exercise is the Effect of Range of Motion, Pain, Function, Muscle Strength of the Shoulder with Women Breast Cancer)

  • 이민지;정성관;김용진
    • 대한정형도수물리치료학회지
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2018
  • Background: The Purpose of this study was investigate the Smovey exercise is the effect of range of motion, pain, function, muscle strength of th shoulder with women breast cancer. Methods: This study was carried out with a total 24 breast cancer survivors. By drawing lots women a breast cancer Smovey exercise group (BS, n=11), a breast cancer general therapy group (BG, n=10). Outcomes such as the range of motion(ROM), visual analogue scale(VAS), the shoulder pain and disability index (SI), the muscle strength (MS) were measured pre- and post-intervention for both groups. Results: A significant increase was found ROM, Pain, functional disability level and MS within the two groups (p<.05). There were ROM, pain, functional disability level and MS post test then invention were significant between the two groups (p<.05). Conclusions: Applying Smovey exercise treatment to breast cancer patients proved to have a positive effect.

유방암 절제술과 견관절 수술을 한 여성의 견관절 관절가동범위, 통증수준, 기능수준, 견갑골의 자세 비교 (Comparison of Shoulder Range of Motion, Pain, Function, Scapular Position Between Breast Cancer Surgery and Shoulder Surgery Female Patients)

  • 이민지;김선엽;심재광
    • 한국전문물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.9-18
    • /
    • 2015
  • This study aimed to compare the characteristics of breast cancer surgery and shoulder surgery patients on the shoulder range of motion (ROM), degree of pain and dysfunction, and scapular position. This study was carried out with a total of 90 women: a breast cancer surgery group (BS, $n_1=30$), a shoulder surgery group (SS, $n_2=30$) and a control group ($n_3=30$). Shoulder ROM, the Quadruple Visual Analogue Scale (QVAS), the Shoulder Pain and Disability Index (SPADI), and the Scapular Index (SI) were used to assess shoulder function. Statistical analyses were performed using a one-way analysis of variance, crosstab test, and independent sample t-test. Post-hoc testing was carried out with Bonferroni test. There were significant differences in shoulder ROM when the BS and the SS were compared with the control group. However, there was no significant difference in ROM between the BS and SS. Furthermore, there was a significant difference in shoulder pain between both surgery groups, and there was greater shoulder dysfunction in the SS than in the BS. There was also a significant difference in upper extremity posture when the BS and the SS were compared to the control group. Finally, there was no significant difference in upper extremity posture between the BS and the SS. This study compared shoulder ROM, pain, dysfunction, and upper extremity postures between the BS and SS. While there were no significant differences in shoulder ROM, pain, and upper extremity posture between both surgery groups, the level of dysfunction was found to be significantly different. Therefore, health professionals managing for breast cancer surgery or shoulder surgery patients should consider these outcomes.

뇌졸중후(腦卒中後) 견관절(肩關節) 수부(手部) 증후군(症候群)의 적외선(赤外線) 체열(體熱) 촬영(撮影)을 이용(利用)한 임상적(臨床的) 관찰(觀察) (Clinical Study with Thermography on Shoulder Hand Syndrome after Stroke)

  • 이상훈;이윤호
    • 대한한의학회지
    • /
    • 제18권1호
    • /
    • pp.25-39
    • /
    • 1997
  • Shoulder hand syndrome is characterized by pain, vasomotor instability, and tenderness, mainly in the distal upper extremity. The pathophysiologic mechanism of this syndrome is not yet proved. The purpose of this study is to evaluate the usefulness of thermographic imaging on shoulder hand syndrome after stroke for early diagnosis and its clinical pattern analysis including acupuncture and electroacupuncture therapy. This study was performed from June to September in 1996 on 46 stroke patients who were admitted at Oriental hospital of Kyung Hee Medical Center. The study group were 23 patients with shoulder hand syndrome. The control group were 23 patients without shoulder hand syndrome. Skin temperatures on the both upper extremities were measured by Digital Infrared Thermographic Imaging(D.I.T.I.) before the study and 3 weeks later again. The results were as follows; 1. The shoulder hand syndrome group were significantly more restricted in shoulder passive range of motion than the control group. 2. The shoulder hand syndrome group showed significant temperature difference of both dorsal hands. 3. The electroacupunture therapy group were significantly more improved on the temperature difference of both dorsal hands than acupuncture therapy group in 3 weeks later. 4. Both posterior arms showed the biggest temperature difference from 11 to 30 days in shoulder hand syndrome group. 5. The lesser passive ROM(range of motion) of shoulder group showed significantly increased temperature difference of both hands. The above results show that measurement of shoulder passive range of motion and D.I.T.I. is a useful method for early diagnosis on shoulder hand syndrome and its clinical pattern analysis including evaluation of acupuncture and electroacupuncture therapy. Continuous study will be needed for more clinical application and evaluation on shoulder hand syndrome.

  • PDF

Comparison of Glenohumeral Stabilization Exercise and Scapular Stabilization Exercise on Upper Extremity Stability, Alignment, Pain, Muscle Power and Range of Motion in Patients With Nonspecific Shoulder Pain

  • Jeon, Na-young;Chon, Seung-chul
    • 한국전문물리치료학회지
    • /
    • 제23권4호
    • /
    • pp.38-46
    • /
    • 2016
  • Background: Shoulder stabilization commonly involves two components: the glenohumeral stabilization exercise (GSE) and scapular stabilization exercise (SSE). Despite the fact that the shoulder stabilization has advantageous merit, to our knowledge, only a few studies have compared the superior of the GSE and the SSE. Objects: The purpose of this study was to assess the effects of GSE in patients with nonspecific shoulder pain. Methods: Thirty subjects with nonspecific shoulder pain were randomly divided into an experimental group and control group, each with 15 patients. The experimental group used an GSE, whereas the control group did SSE. All subjects were measured in shoulder stability, scapular symmetric alignment, pain, muscle power, and range of motion before and after the intervention. Results: GSE resulted in significantly better shoulder stability (p=.046, from $8.67{\pm}7.54$ score to $13.93{\pm}9.40$) in the experimental group compared with SSE in the control group. However, no significant effects were observed for scapular symmetric alignment including the angles of inferior scapular distance (p=.829) and inferior scapular height difference (p=.735), pain (p=.113), muscle power including shoulder flexion (p=.723) and abduction (p=.897) and range of motion including shoulder flexion (p=.853) and abduction (p=.472). Conclusion: These findings suggest that GSE may be more effective in increasing the shoulder stability than the SSE in patients with nonspecific shoulder pain, probably through a centralization effect on the shoulder mechanism.

뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구 (Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke)

  • 박일우;임원빈;박규남;이충휘
    • 한국전문물리치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

볼을 이용한 감각운동훈련이 유방암 절제술 후 여성의 어깨 기능과 삶의 질에 미치는 효과 (The Effects of Sensory Motor Training Using Ball Exercise on Shoulder Functions and Quality of Life in Breast Cancer Women After Mastectomy)

  • 서지윤;최종덕
    • 대한물리의학회지
    • /
    • 제11권4호
    • /
    • pp.147-156
    • /
    • 2016
  • PURPOSE: The purpose of this study was to investigate the effects of sensory motor training using ball exercise on shoulder range of motion, pain, dysfunction, and quality of life in Breast Cancer Women after Mastectomy. METHODS: A total of 26 patients from D University Hospital in Daejeon were included and randomly allocated to two groups (n=13 per group). The two groups performed the exercise five times a week for 4 weeks. A sensory motor training group (SMTG) received general physical treatment for 10 minutes and sensorimotor training for 20 minutes. A control group (CG) received general physical therapy for 30 minutes. Shoulder pain (the Visual Analog Scale), range of motion, disability (the shoulder pain and disability index) and quality of life (the Functional Assessment Cancer Therapy-Breast instrument) were measured in both groups before and after 4-weeks intervention. RESULTS: A significant difference was found in joint range of motion, shoulder pain, functional disability level, and quality of life within the two groups (p <.05). In addition, changes in joint range of motion, pain, functional disability level, and quality of life after then intervention were significantly different between the two groups (p <.05). CONCLUSION: These results suggest that a sensory motor training program is feasible, safe, and suitable exercise for shoulder functions and quality of life in Breast Cancer Women after Mastectomy.

비디오 게임을 이용한 재활운동이 뇌졸중 편마비 환자의 상지 관절가동 범위와 통증, 스트레스에 미치는 효과 (The Effects of Rehabilitation Training Using Video Game on Improvement Range of Motion for Upper-Extremity, Shoulder Pain and Stress in Stroke Patients with Hemiplegia)

  • 변필숙;전미영
    • 근관절건강학회지
    • /
    • 제19권1호
    • /
    • pp.46-56
    • /
    • 2012
  • Purpose: This study was to evaluate the effects of rehabilitation training using video game on improvement range of motion for upper -extremity, shoulder pain and stress in stroke patients with hemiplegia. Methods: The study utilized nonequivalent control group non-synchronized design. Participants are sampled from a group of people who are hospitalized in rehabilitation medicine ward at 'K' university hospital in 'S' city from January 1st 2011 to October 31th. Each 28members of control group and experimental group, total 56members were participated. One task is for 10minutes, and the video game for total 30minutes performed 5 times a week, for 3weeks. Data were analyzed by SPSS WIN 17.0. Results: The range of motion for upper-extremity in experimental group was significantly different from that in control group(shoulder flexion t=7.70, $p$ <.001, extension t=7.80, p<.001, abduction t=6.95, $p$ <.001, elbow flexion t=6.47, $p$ <.001). The shoulder pain score in experimental group was significantly different from that in control group(t=-14.58, $p$ <.001). The level of stress in experimental group was significantly different from that in control group(t=-4.89, $p$ <.001). Conclusion: The result proved that rehabilitation training using video game was an effective stroke patients to increase in range of motion for upper-extremity and decrease in the shoulder pain, stress.

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.