• 제목/요약/키워드: Short measured method

검색결과 577건 처리시간 0.026초

역해석기법을 이용한 현수교 행어케이블 장력 추정 (Back Analysis for Estimating Tension Force on Hanger Cables)

  • 김남식;빈정민;장성진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.894-901
    • /
    • 2006
  • In general, the tension fores of hanger cable in suspension bridges play an important role in evaluating the bridge state. The vibration method, as a conventional one, has been widely applied to estimate the tension fores by using the measured frequencies on hanger cables. However, the vibration method is not applicable to short hanger cables because the frequency of short cables is severely sensitive to the flexural rigidity. Thus, in this study, the tension forces of short hanger cables, of which the length is shorter than 10meters, were estimated through back analysis of the cable frequencies measured from Gwang-An suspension bridge in Korea. Direct approach to rock analysis is adopted using the univariate method among the direct search methods as an optimization technique. The univariate method is able to search the optimal tension forces without regard to the initial ones and has a rapid convergence rate. To verify the feasibility of back analysis, the results from back analysis and vibration method are compared with the design tension forces. From the comparison, it can be inferred that back analysis results are more reasonable agreement with the design tension forces of short hanger cable. Therefore, it is concluded that back analysis applied in this study is an appropriate tool for estimating tension forces of short hanger cables.

  • PDF

원형-구형 도파관 변환부의 특성 측정 방법 연구 (A study on a Measurement Method of the Circular-to-Rectangular Waveguide Transition characteristics.)

  • 최병철;신동숙;방재훈;안병철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.211-214
    • /
    • 2002
  • In this paper, we present a simple method for characterizing a rectangular waveguide to circular waveguide transition Three standard loads consisting of a short circuit, an offset short circuit 1, and an offset short circuit 2 are sequentially connected to the circular waveguide port and the reflection coefficient at port 1 Is measured for each case. From known reflection coefficients, of standard loads and measured reflection coefficients, the scattering matrix of the transition Is obtained. The proposed method Is verified by the numerical experiment using a commercial software HFSS and by measurments of a actual rectangular-to-circular waveguide transition.

  • PDF

침수에 의한 누전지역의 자속밀도 영향 (Influence of Flux Density of Electric Leakage Area by Inundation)

  • 최운식;김탁용;김진사
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1109-1113
    • /
    • 2010
  • Recently, important for the safety has been increasing together economic developments. The leakage only is measured by the voltage difference. This method is a way to contact the electric leakage area. It can cause electric shock at users. We propose a non-contact method to detect a short circuit in this paper. We investigate magnetic field at electric leakage area to present non-contact method. Simulated environment created a short circuit in the flooded areas. Voltage is supplied 50, 150 and 200[V]. Magnetic field was measured at 0, 5 and 10[cm]. Magnetic flux was reduced about $0.4[{\mu}T/cm]$ depending on the distance changes in the steady region. But we confirmed that magnetic flux is measured the same value depending on the distance changes in the electric leakage area.

피로균열개구거동을 이용한 짧은균열의 거동 분석 (Short Crack Analysis by Fatigue Crack Opening Behavior)

  • 송삼홍;이경로
    • 한국정밀공학회지
    • /
    • 제14권4호
    • /
    • pp.136-144
    • /
    • 1997
  • The characteristics of fatigue crack growth subject to out-of-plane bending fatigue are studied in terms of crack opening behavior by using pre-cracked smooth specimens. Crack opening stress is measured by an elastic compliance method which may precisely and continuously provide many date using strain gages during experiment. The results of the short crack and the long crack arranged by crack closure concept show that the effective stress gange ratio of short crack is grester than that of long crack, and ano- malous growth behavior of short crack may be elucidated by the variation of crack opening stress. When the variation of fatigue crack growth rate is arranged versus effective stress intensity factor range. Iinear relation is held also for the short crack. It shows that growth behavior of short crack can be quantitatively represent- ed by the fracture mechanics parameter using effective stress intensity factor range.

  • PDF

1 안테나 법에 의한 미소 간극의 방전 전류파형 추정 (Estimation of Discharge Current Waveshapes in Short Gap Discharge by One Antennal Method)

  • 김기채;이광식;이동인
    • 한국전자파학회논문지
    • /
    • 제9권4호
    • /
    • pp.499-505
    • /
    • 1998
  • 본 논문에서는 미소 간극에서 방전이 일어날 때 발생하는 방사 전자파를 측정하여 이로부터 방전전류의 파형을 추정하는 방법에 관하여 검토하고 있다. 한 개의 시간영역 전자계 측정용 안테나를 사용하여 주어진 위취에서 관측한 측정 전계 또는 측정 자계로부터 방전전류를 추정하는 1 안테나 법(단일 전자계 법)의 이론을 확립하고, Wilson & Ma 가 측정한 전계를 이용하여 1 안테나 법에 의한 방정전류의 파형을 추정(복원)하고 있다. 추정된 방전전류의 파형은 방전전류의 측정 결과와도 비교하여 1 안테나 법에 의한 추정법 이론이 타당함을 확인하고 있다.

  • PDF

계통변화를 고려한 자율 적응형 과전류 계전기 (Autonomous Adaptive Digital Over Current Relay)

  • 윤준석;최면송;이승재;현승호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.444-449
    • /
    • 2003
  • In this paper present Autonomous Adaptive Digital Over Current Relay for distribution networks which acts autonomous setting using the short circuit impedance measured by relay of power systems. Automation of relay setting is one of the basic requirements for distribution automation, although manual relay setting is used at present. The short circuit impedance from a power source in distribution networks essential for the Autonomous Relay Setting changes frequently in distribution networks. In this paper the short circuit impedance is calculated with voltage and current measured in real time operation of digital relay using the Recursive Least Squares. A new method of digital relay setting is introduced using the the short circuit impedance and load current.

암석의 파괴인성 측정에서 나타나는 CB 시험편의 치수효과에 관하여 (The Size Effect in Measuring the Fracture Toughness of Rock using Chevron Bend Specimen)

  • 김재동;백승규
    • 터널과지하공간
    • /
    • 제2권2호
    • /
    • pp.251-264
    • /
    • 1992
  • In this study, the size effect in measuring the fracture toughness of rock was investigated using the ISRM Suggested Method for Fracture toughness using Chevron Bend Specimens. Total 58 specimens were prepared with 4 different diameters, 29, 42, 54, 68mm and center cut-chevron notch. In addition to this, to evaluated the effect of anisotropy of Jecheon granite, which is the sample for this study, core drilling direction was adjusted perpendicular(short transverse) and parallel(arrester) to the rift plane in the sample and the measured fracture toughness for each direction were compared. Important results obtained from this study are as follows. Level ll test condition is more adequate than l, because of low data scattering and precision and corrected fracture toughness of Jechoen granite measured and 2.2MPa{{{{ SQRT { m} }}}} for arrester direction with minimum initial crack length 0.7cm. From the relationship between core diameter and initial crack length presented in the ISRM testing method, the specimen diameter should be bigger than 47mm. The fracture toughnesses measured for arrester and short transverse directon show 10% difference. This is to the anisotropy of Jecheon granite possessing rift plane.

  • PDF

전기적 측정법을 사용한 팬케이크 코일에서의 교류손실 측정 (AC Losses of the HTS Pancake Coil by Using Electric Method)

  • 이승욱;임형우;최명섭;이희준;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2003
  • This paper presents calculated and measured AC losses of the HTS pancake coil. Magnetic field in the HTS coil under operating conditions was calculated by FEM. Results of measured ac loss in 4-stacked short sample were used in the AC loss calculation. Various methods, such as, electric method, calorimetric method, wattmeter method, were used to measure the AC loss.

  • PDF

Combining Distributed Word Representation and Document Distance for Short Text Document Clustering

  • Kongwudhikunakorn, Supavit;Waiyamai, Kitsana
    • Journal of Information Processing Systems
    • /
    • 제16권2호
    • /
    • pp.277-300
    • /
    • 2020
  • This paper presents a method for clustering short text documents, such as news headlines, social media statuses, or instant messages. Due to the characteristics of these documents, which are usually short and sparse, an appropriate technique is required to discover hidden knowledge. The objective of this paper is to identify the combination of document representation, document distance, and document clustering that yields the best clustering quality. Document representations are expanded by external knowledge sources represented by a Distributed Representation. To cluster documents, a K-means partitioning-based clustering technique is applied, where the similarities of documents are measured by word mover's distance. To validate the effectiveness of the proposed method, experiments were conducted to compare the clustering quality against several leading methods. The proposed method produced clusters of documents that resulted in higher precision, recall, F1-score, and adjusted Rand index for both real-world and standard data sets. Furthermore, manual inspection of the clustering results was conducted to observe the efficacy of the proposed method. The topics of each document cluster are undoubtedly reflected by members in the cluster.

전자계-기계계 결합해석에 의한 건식변압기의 단락강도 예측 (Short Circuit Electromagnetic Force Prediction by Coupled Electromagnetic-Mechanical Field Analysis of Dry-Type Transformer)

  • 안현모;한성진
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.301-308
    • /
    • 2011
  • This paper deals with the coupled electromagnetic-mechanical field analysis for short-circuit electromagnetic force of the dry-type transformer. The short-circuit currents are calculated using external circuit in accordance with short-circuit test equipment. According to short-circuit current, the generated magnetic leakage flux density in dry-type transformer model is calculated by finite element method. The radially-directed electromagnetic forces in windings are calculated using electromagnetic field analysis and then axially-directed electromagnetic forces in windings are calculated using electromagnetic-mechanical field analysis. The calculated axially-directed electromagnetic forces in high voltage winding are compared to those of measured ones and showed good agreement with experimental results.