• Title/Summary/Keyword: Short circuit test

Search Result 259, Processing Time 0.028 seconds

Short Circuit Test of Power Transformer for Evaluation of Numerical Analysis (전산해석 검증을 위한 전력용 변압기의 단락강도 측정)

  • Oh, Y.H.;Song, K.D.;Sun, C.H.;Kim, S.C.;Woo, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.793-795
    • /
    • 2002
  • This study shows method of measuring mechanical stresses during short circuit test, to evaluate numerical analysis of short circuit force. As test model, 400kVA transformers are used, to acquire short circuit force acceleration sensors used. Weak region of winding is found through short circuit test, and verification data of numerical calculation is obtained.

  • PDF

A Study on Failure Analysis of Low Voltage Breakers with Aging (경년열화에 따른 배선용 차단기류의 고장점 분석 연구)

  • Cho, Han-Goo;Lee, Un-Yong;Lee, You-Jung;Lee, Hae-Ki;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.501-502
    • /
    • 2006
  • In this paper, new and aging sample of MCCB and ELCB are investigated the main performance test such as short circuit test, mechanical and electrical endurance test, dielectric test and surge current test. The surface conditions of new and aging sample are analyzed by SEM, TGA and DSC. The ELCB occurred badness mainly in short circuit test and surge current test. The badness cause of short circuit test was confirmed due to imperfect contact of contact part.

  • PDF

Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter (6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF

Development of Smart ICT-Type Electronic External Short Circuit Tester for Secondary Batteries for Electric Vehicles (전기자동차용 2차전지를 위한 스마트 ICT형 전자식 외부 단락시험기 개발)

  • Jung, Tae-Uk;Shin, Byung-Chul
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.333-340
    • /
    • 2022
  • Recently, the use of large-capacity secondary batteries for electric vehicles is rapidly increasing, and accordingly, the demand for technologies and equipment for battery reliability evaluation is increasing significantly. The existing short circuit test equipment for evaluating the stability of the existing secondary battery consists of relays, MCs, and switches, so when a large current is energized during a short circuit, contact fusion failures occur frequently, resulting in high equipment maintenance and repair costs. There was a disadvantage that repeated testing was impossible. In this paper, we developed an electronic short circuit test device that realizes stable switching operation when a large-capacity power semiconductor switch is energized with a large current, and applied smart ICT technology to this electronic short circuit stability test system to achieve high speed and high precision through communication with the master. It is expected that the inspection history management system based on data measurement, database format and user interface will be utilized as essential inspection process equipment.

A Study on the Cause and Countermeasures of the Short-Circuit Test Failures of the Distribution Transformer (배전용 변압기의 단락시험 불량원인 및 그 대책에 관한 연구)

  • Park, Byung-Rak;Park, Hoon-Yang;Shin, Hee-Sang;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.75-81
    • /
    • 2011
  • This study aims to research and analyze the cause and countermeasures of the short-circuit test failures of the distribution transformer, which captures failure share at the highest level when carrying out its performance test. For this purpose, the research was done on the basis of 77 failure cases out of 998 tests in total performed by the Korea Electrotechnology Research Institute(KERI) from 2004 to 2010. Based on the research, the paper also includes analysis of the causes of the short-circuit test failures in its early stage of transformer development and proposes its countermeasures accordingly.

Short Circuit Electromagnetic Force Prediction by Coupled Electromagnetic-Mechanical Field Analysis of Dry-Type Transformer (전자계-기계계 결합해석에 의한 건식변압기의 단락강도 예측)

  • Ahn, Hyun-Mo;Hahn, Sung-Chin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.301-308
    • /
    • 2011
  • This paper deals with the coupled electromagnetic-mechanical field analysis for short-circuit electromagnetic force of the dry-type transformer. The short-circuit currents are calculated using external circuit in accordance with short-circuit test equipment. According to short-circuit current, the generated magnetic leakage flux density in dry-type transformer model is calculated by finite element method. The radially-directed electromagnetic forces in windings are calculated using electromagnetic field analysis and then axially-directed electromagnetic forces in windings are calculated using electromagnetic-mechanical field analysis. The calculated axially-directed electromagnetic forces in high voltage winding are compared to those of measured ones and showed good agreement with experimental results.

A Study on 30 kVA Super-Conducting Generator Performance using Open Circuit, Short Circuit Characteristics, and Load Tests (개방회로, 단락회로 특성시험 및 부하시험을 이용한 30 kVA 초전도 발전기의 특성해석)

  • Ha, Gyeong-Deok;Hwang, Don-Ha;Park, Do-Yeong;Kim, Yong-Ju;Gwon, Yeong-Gil;Ryu, Gang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.2
    • /
    • pp.85-92
    • /
    • 2000
  • 30 kVA rotating-field type Super-Conducting Generator is built and tested with intensive FE(Finite Element) analysis. The generator is driven by VVVF inverter-fed induction motor. Open Circuit Characteristic(OCC) and Short Circuit Characteristic(SCC) are presented in this paper. Also, the test result under the light load(up to 3.6 kW) are given. From the design stage, 2-D FE analysis coupled with the external circuit has been performed. The external circuit includes the end winding resistance and reactance as well as two dampers. When compared with the test data, the FE analysis results show a very good agreement.

  • PDF

The Study of Comparison of the Symmetrical Short Circuit Test Current with ANSI/IE Transformers. (변압기의 단락강도 시험 시 ANSI와 IEC 규격에 의한 시험 전류의 비교 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jeong, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.694-696
    • /
    • 2002
  • Transformers together with all equipment and accessories shall be designed and constructed to withstand the mechanical and thermal stresses produced by external short circuit which include three phase, single line-to-ground, double line-to-ground and line-to-line faults etc. Generally the Short Circuit Test of transformers is tested according to the ANSI/IEEE, IEC/JEC, KS etc, in domestic. In this study, it will be showed and compared the difference of symmetrical current for short circuit test of a Pad -mounted transformer according to with ANSI /IEEE and IEC.

  • PDF

Parameters Optimization of Impulse Generator Circuit for Generating First Short Stroke Lightning Current Waveform

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents the parameters optimization technology for generating the first short stroke lightning current waveform($10/350{\mu}s$) which is necessary for the performance tests of components of lightning protection systems, as required under IEC 62305 and the newly amended IEC 62561. The circuit using the crowbar device specified in IEC 62305 was applied to generate the lightning current waveform. To find the proper parameters of the circuit is not easy because the circuit consists of two parts; circuit I, which relates to the front of current waveform, and circuit II, which relates to the tail. A simulation in PSpise was carried out to find main factors related to the front and tail of $10/350{\mu}s$. The lightning current generator was developed by utilizing the circuit parameters found in the simulation. In the result of experiments, new parameters of the circuits need to be changed because of the difference between the simulation and the experiment results. Using the iterative method, the optimized parameters of the circuits was determined. Also a multistage-type external coil and a damping resistor were proposed to make the efficiency of generation to enhance. According to the result in this paper, an optimized first short stroke lightning current waveform was obtained.

Short-circuit making and breaking test for 362kV, 63kA circuit breaker (362kV, 63kA 초고압차단기 투입차단시험)

  • Park Seung Jae;Suh Yoon Taek;Yoon Hack Dong;Kim Maeng Hyun;Koh Heui Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.554-556
    • /
    • 2004
  • Testing capacity of KERI synthetic short-circuit testing facilities has been upgraded to fulfill the requirements up to 550kV 63kA, 1-break circuit breaker ratings. Specially the current capacity was increased 50kA to 63kA and the full type test of 362kV 63kA circuit breaker(1-break) was firstly completed in domestic. UP to now, domestic manufacturers have depended on the foreign testing laboratory for performance verification of newly designed products. This paper introduces the summary of the increased short-circuit testing facilities, the testing techniques and its results for the making and breaking performance of 362kV, 63kA circuit breaker which was Performed according to IEEE C37.06(1999) used in North America.

  • PDF