• Title/Summary/Keyword: Short circuit frequency

Search Result 175, Processing Time 0.028 seconds

A study on the compensator design of the quasi-resonant SMPS (유사공진형 SMPS의 보상기 설계에 관한 연구)

  • Lim, I.S.;Huh, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.720-725
    • /
    • 1991
  • In this thesis, the lead-lag compensator is designed to improve output characteristics of flyback zero voltage switching quasi-resonant converters. The switch and the diode are assumed ideally. And the SMPS is modelled by state equations with four operation modes. And the model for controller design is also achived by using a state space averaging method, which is continuous time average of state variables every period. The lag, the lead and the lead-lag compensator is designed the SMPS respectively. The time domain analysis and the frequency domain analysis are done for each compensated circuit. It is possible increasing the phase margin and improving the transient response by the compensators. The phase lag compensator has small overshoot comparatively. But the bandwidth is narrower than the others, so it has longest settling time. For the phase lead compensator, the response come to steady-state within short period. But the overshoot is the largest due to its large peak gain. Finally, the phase lead-lag compensator has medium characteristics in the overshoot and the settling time.

  • PDF

Development of a Voltage Sag Assessment Program Considering Generator Scheduling and Voltage Tolerance (발전기 스케줄링과 부하 전압민감도를 고려한 순간전압강하 평가 프로그램 개발)

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.92-100
    • /
    • 2009
  • This paper presents a voltage sag assessment program. The program provides various functions for stochastic assessment of voltage sags such as short-circuit analysis, the determination of the area of vulnerability and the calculation of expected sag frequency(ESF). Effective data visualization functions based on computer graphics and animation were also implemented in the developed program. In this paper, the concept of voltage sag assessment and the assessment method considering generator scheduling and time-varying fault rates are presented. The influence of generator scheduling and time-varying fault rates on voltage sag prediction is also described by performing case studies using the developed program.

Design of an Electrically Small Antenna Using Metamaterial Structure (메타물질 구조를 이용한 전기적 소형 안테나의 설계)

  • Lee, Hong-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.24-30
    • /
    • 2010
  • In this paper, a novel electrically small monopole type resonant antenna is proposed. The very short length monopole (${\iota}{\approx}{\lambda}_g/15$ ) acts as a capacitive element and the slot on the ground structure acts as an inductive element, hence the combined system with these two elements thus form an LC resonator. The equivalent circuit model of the antenna structure was used to analysis and qualify the design correctness. Although the proposed antenna has very small size, it shows good performances. The measured maximum gain and radiation efficiency of the fabricated antenna at the frequency of 2.1 GHz was 3.6 dBi and 77.8 %, respectively.

  • PDF

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

A Study on Basic Characteristics of a Coplanar-type Transmission Line Employing Periodic Structure on Si RFIC (Si RFIC상에서 주기적 구조를 이용한 코프레너형 전송선로의 기본특성연구)

  • Joh, Han-Nah;Park, Young-Bae;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.964-973
    • /
    • 2008
  • In this study, a short-wavelength coplanar-type transmission line employing periodic ground structure (PGS) was developed for application to miniaturized on-chip passive component on Si Radio Frequency Integrated Circuit (RFIC). The transmission line employing PGS showed shorter wavelength and lower characteristic impedance than conventional coplanar-type transmission line. The wavelength of the transmission line employing PGS structure was 57 % of the conventional coplanar-type transmission line on Si substrate. Using the theoretical analysis. basic characteristics of the transmission line employing PGS (e.g., bandwidth. loss, impedance, and resonance characteristics) were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components on silicon RFIC. According to the results. the bandwidth of the transmission line employing PGS was more than 895 GHz as long as T is less than 20${\mu}m$, and the resonance characteristic was observed in 1239 GHz, which indicates that the PPGM structure is a promising candidate for application to a development of miniaturized on-chip passive components on Si RFIC.

A Novel Unequal Broadband Out-of-Phase Power Divider Using DSPSLs

  • Lu, Yun Long;Dai, Gao-Le;Li, Kai
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.116-123
    • /
    • 2014
  • In this paper, a novel unequal broadband out-of-phase power divider (PD) is presented. Double-sided parallel-strip lines (DSPSLs) are employed to achieve an out-of-phase response. Also, an asymmetric dual-band matching structure with two external isolation resistors is utilized to obtain arbitrary unequal power division, in which the resistors are directly grounded for heat sinking. A through ground via (TGV), connecting the top and bottom sides of the DSPSLs, is used to short the isolation components. Additionally, this property can efficiently improve the broadband matching and isolation bandwidths. To investigate the proposed divider in detail, a set of design equations are derived based on the circuit theory and transmission line theory. The theoretical analysis shows that broadband responses can be obtained as proper frequency ratios are adopted. To verify the proposed concept, a sample divider with a power division of 2:1 is demonstrated. The measured results exhibit a broad bandwidth from 1.19 GHz to 2.19 GHz (59.2%) with a return loss better than 10 dB and port isolation of 18 dB.

The study on the characteristics of transient recovery voltage of electromagnetic contactor (전자기 접촉기의 과도회복전압 특성에 대한 연구)

  • Kim, Geun-Yong;Ryu, Jae-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.834-835
    • /
    • 2008
  • 전자기 접촉기(electromagnetic contactor)는 교류 또는 직류 저압의 전로(電路)에 사용되는 부하개폐기의 한 종류로 전자석 코일(electromagnet coil)의 여자(勵磁)에 의하여 주 접촉자를 개폐시키는 기기이다. 일반적으로 전자기 접촉기는 단락전류를 차단하도록 설계되어 있지는 않다. 그러므로 설치 시 적절한 단락 보호가 이루어져야 하며, 반드시 접촉기의 일부분일 필요는 없다. 차단기와 퓨즈 등을 단락보호장치(SCPD, Short-Circuit Protective Device)로 많이 사용한다. 전자기 접촉기는 특히 고빈도 개폐를 목적으로 사용되는 개폐기로, 농형모터(squirrel-cage motors)의 시동, 운전 중의 정지, 플러깅(plugging, 모터가 운전하고 있는 중에 모터의 1차측 접속을 역으로 바꿔서 모터를 급격히 정지시키거나 역 회전시키는 것) 및 인칭(inching, 모터를 짧은 기간 동안 1회 또는 반복 여자해서 피동기구를 조금 이동시키는 것)에 많이 쓰인다. 이러한 기기의 개폐특성을 평가하기 위한 부하는 과도회복 전압의 진동 주파수(oscillatory frequency)와 진폭율 ${\gamma}$를 얻을 수 있도록 조정되어야 한다. 본 논문에서는 고빈도 개폐능력을 갖고 있는 전자기 접촉기의 과도회복 전압 특성과 그 특성을 얻기 위한 부하 회로의 조정방법에 대해 고찰하였다.

  • PDF

A Study on the Impact of HVDC Transmission System to Interconnect Large-scale Power Generation Plants to Power Grid in Korea (HVDC 송전을 이용한 동해안 신규전원의 수도권 계통 연계방안에 대한 연구)

  • Han, Su-Young;Gwon, Do-Hun;Chung, Il-Yop;Lim, Jae-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1647-1656
    • /
    • 2013
  • Although the demand for electricity has been increasing these days, it becomes more difficult to find new sites for large-scale power generation plants near urban areas due to environmental and economic issues. Therefore, new power plants are forced off to rural or desolate coastal areas. As a result, there is significant regional imbalance in power generation and consumption between urban and rural areas in South Korea. This paper investigates the feasibility of high-voltage DC (HVDC) system as a candidate for electric power transmission system from east-coastal sites to metropolitan area. To this end, this paper analyzes transient stability and dynamic impact of a HVDC transmission system and compares the results to conventional high-voltage AC (HVAC) transmission systems via PSS/E simulation. This paper also examines the effect of HVDC system to voltage variation and low-frequency resonance in the neighboring buses in the grid using ESCR(Effective Short Circuit Ratio)과 UIF(Unit Interaction Factor) indices.

A Study on the Change of Dynamic Characteristics of Stator Windings due to Generator Operation (발전기 운전에 따른 고정자 권선의 진동 특성 변화)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Doo-Young;Kim, Yeon-Whan;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1029-1033
    • /
    • 2006
  • During operation of generator, the excitation force with 120Hz always exist irrespective of No. of poles. Therefore the vibration is generated in the stator end windings and the micro-crack is grown up inside the bars. After all, coolant water is leaked outside the bars or the stator is moved and is worn out. What is more, one bar is touched with another bar so a short circuit may frequently happen in operation. In order to prevent it from occurring, the evaluation of mechanical integrity for generator stator windings is carried out periodically during overhaul period. This help troublesome end windings to complement with insulation material and to change vibration characteristics. In this paper, the evaluation of mechanical integrity for generator stator windings is described and the change of vibration characteristics is analysed.

  • PDF

Resolution of a Multi-Step Electron Transfer Reaction by Time Resolved Impedance Measurements: Sulfur Reduction in Nonaqueous Media

  • Park, Jin-Bum;Chang, Byoung-Yong;Yoo, Jung-Suk;Hong, Sung-Young;Park, Su-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.9
    • /
    • pp.1523-1530
    • /
    • 2007
  • The first reduction peak of the cyclic voltammogram (CV) for sulfur reduction in dimethyl sulfoxide has been studied using time resolved Fourier transform electrochemical impedance spectroscopic (FTEIS) analysis of small potential step chronoamperometric currents. The FTEIS analysis results reveal that the impedance signals obtained during short potential steps can be resolved into electron transfer reactions of two different time constants in a high frequency region. The FTEIS method provides snap shots of impedance profiles during an earlier phase of the reaction, leading to time resolved EIS measurements. Our results obtained by the FTEIS analysis are consistent with a series of electron transfer and chemical equilibrium steps of a complex reaction, making up an ECE (electrochemical-chemical-electrochemical) mechanism postulated from the results of computer simulation.