• 제목/요약/키워드: Short Fault

검색결과 531건 처리시간 0.03초

순간전압강하에 대한 동적전압보상기 (Dynamic Voltage Compensator for Voltage Sag)

  • 한병문;한경희;배정환;김희중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2047-2049
    • /
    • 1997
  • Computers and automatic equipment are very sensitive to the disturbances such as voltage transients, voltage sag, and harmonics. These disturbances cause them to have a malfunction or fault which brings about damages and losses. UPS (uninterruptible power supply) and SPS(stand-by power supply) have been used to provide the required voltage in a critical load without disturbances. However, UPS has appreciable losses due to the operation of the inverter in full rated power at all times. SPS, although whose inverter losses are smaller than those of UPS, transfers disturbances with a short duration to the load, due to the limited reaction time. In this research, a dynamic voltage compensator, which can make up for the weakness of UPS and SPS, is proposed. The operation of the proposed system was verified by a computer simulation. A hardware scaled-model was fabricated and tested to conform the feasibility of the actual system development.

  • PDF

복합소호형 가스 차단기의 SLF 차단 성능 해석 (Analysis of SLF Interruption Performance in self-blast Gas Circuit Breaker)

  • 박진근;안희섭;최종웅;김영근;조해용
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.24-32
    • /
    • 2020
  • A self-blast type gas circuit breaker has been studied in this study to improve efficiency of interrupting performance of short line fault(SLF). Hot gas flows of gas circuit breaker have been simulated to evaluate interruption performance using CFD. Design parameters such as various types of expansion chamber and nozzles are suggested by using simulation results. Simulated results and experimental ones are compared with previous (ones that of in under development and with capacitor) GCB. Modified new shape of an expansion chamber and nozzle has been suggested to improve the efficiency of gas flow and to provide guidelines for designing self-blast breaker with a higher interruption capability.

직렬 전압주입에 의한 순간전압강하 보상기기에 관한 연구 (A Study on the Instantaneous Voltage Drop Compensator through the Series Voltage Injection)

  • 전영환;김지원;전진홍
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.310-317
    • /
    • 2001
  • 동일한 변압기에서 인출된 서로 다른 선로중 하나의 선로에서 고장이 발생하는 경우 다른 선로에서는 순간적인 전압강하 현상을 경험하게 된다. 이렇게 발생되는 순간전압강하 현상은 비록 선로의 계전기에 의해 사고가 제거되기까지의 짧은 기간동안 지속되지만 기기에 따라서는 막대한 피해를 유발할 수 있다. 예로서, 반도체 공장의 정밀 공정중 순간전압강하가 발생하면 공정이 중단되거나 공정의 재시작등으로 인하여 a가대한 경제적 손실을 유발하게 된다. 또한 각종 정밀기기 등에는 기기의 수명저하를 유발하기도 한다. 본 논문에서는 전력계통에 직렬로 연결되는 인버터 시스템을 이용하여 계통에 전압을 주입함으로서 순간전압강하를 보상할 수 있는 시스템에 관하여 연구하고 운전 알고리즘을 제시하였다. 컴퓨터 시뮬레이션과 실험을 통하여 제시한 운전알고리즘의 유효성을 입증하였다.

  • PDF

변압기 권선변형 진단에 적용하기 위한 LVI 시험기 개발 (The development of LVI tester for application of transformers winding deformation diagnosis)

  • 조국희;김광화
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.97-103
    • /
    • 2002
  • 본 논문은 LVI 시험기를 개발하여 모델 변압기 및 유입식 변압기에 적용해 LVI 시험 분석기술을 개발하였다. LVI시험기는 본체, 터미널 박스 및 케이블로 구성하였고, ANSI규격에서 요구하는 출력특성을 갖도록 설계 제작하였다. 모델 변압기는 탭들을 만들어 변압기의 권선변형 모델을 만들 수 있도록 하였고, 유입식 변압기는 실제 현장에서 사용되는 3상 변압기이다. LVI 시험기는 펄스폭이 1000 ㎱ 이하의 파두 시간과 펄스 최대 전압 500 V로 제작되었다. LVI 시험기로써 실험을 실시하여 성능을 평가한 결과 측정된 파형 분석으로 권선의 축방향과 반경방향으로의 움직임을 구별할 수 있어 변압기 예방 진단에도 효과가 기대된다.

지수를 적용한 수도권 융통전력한계량 계산 (The Calculation Method with index for the Transfer Power limit to Capital Area)

  • 이운희;강명장;송석하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.50-52
    • /
    • 2008
  • We have limited the transfer power to capital area below a certain level which is called "The Capital Area Transfer Power Limit", and calculated on every Thursday for the application next week. This level is very important in our network operation, because if this level is not set properly, our power network can be fallen under great danger in case of a fault among the transfer power line. But the calculation procedure for the limit level is so complicated and iterative that it mace us spend much time and do much work. So, when a sudden trip of the related facility to the limit level we can't recalculate the limit level fast enough. And this can drop our network reliability below our standards, therefore our network can be dangerous. To avoid this kind of problems, we have figured out a method to calculate simply the limit level. That method uses the index related to the level. We think this method can make short of the calculation procedures for the level. This paper deals with the simplified method for the calculation of the level limit.

  • PDF

460[V]/400[A]/85[kA] 배선용 차단기의 그리드 및 아크런너 변형을 통한 차단성능 향상 (Improvement of Short Circuit Performance in 460[V]/400[A]/85[kA] Molded Case Circuit Breakers)

  • 이승수;정의환;윤재훈;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1451_1452
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker depends on the shape, arrangement, and kinds of material of grids. This paper is focused on understanding the interrupting capability, more specifically of the grid and the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구 (A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems)

  • 김찬혁;박현석;노대석;신창훈;윤기갑
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

Main challenges for deep subsea tunnels based on norwegian experience

  • Nilsen, Bjorn
    • 한국터널지하공간학회 논문집
    • /
    • 제17권5호
    • /
    • pp.563-573
    • /
    • 2015
  • For hard rock subsea tunnels the most challenging rock mass conditions are in most cases represented by major faults/weakness zones. Poor stability weakness zones with large water inflow can be particularly problematic. At the pre-construction investigation stage, geological and engineering geological mapping, refraction seismic investigation and core drilling are the most important methods for identifying potentially adverse rock mass conditions. During excavation, continuous engineering geological mapping and probe drilling ahead of the face are carried out, and for the most recent Norwegian subsea tunnel projects, MWD (Measurement While Drilling) has also been used. During excavation, grouting ahead of the tunnel face is carried out whenever required according to the results from probe drilling. Sealing of water inflow by pre-grouting is particularly important before tunnelling into a section of poor rock mass quality. When excavating through weakness zones, a special methodology is normally applied, including spiling bolts, short blast round lengths and installation of reinforced sprayed concrete arches close to the face. The basic aspects of investigation, support and tunnelling for major weakness zones are discussed in this paper and illustrated by cases representing two very challenging projects which were recently completed (Atlantic Ocean tunnel and T-connection), one which is under construction (Ryfast) and one which is planned to be built in the near future (Rogfast).

주기억 장치 DBMS ALTIBASE의 요소기술 성능평가 (Performance Analysis of High Technologies in Main Memory DBMS ALTIBASE)

  • 이규웅
    • 한국콘텐츠학회논문지
    • /
    • 제5권3호
    • /
    • pp.1-8
    • /
    • 2005
  • ALTIBASE 시스템은 메인 메모리를 주 저장장치로 사용하는 관계형 주기억장치 DBMS이다. 본 논문에서는 최근 데이터베이스 응용들의 요구사항으로 부각되고 있는 데이터베이스의 고가용성과 실시간 데이터베이스 시스템의 높은 트랜잭션 처리율을 동시에 보장하기 위하여 ALTIBASE 시스템의 구조에 대하여 기술하고 설계 요소 기술에 대한 성능 분석 및 평가 결과를 보인다. 표준 성능평가 방법인 Wisconsin 벤치마크 테스트 결과 및 TPC-H 성능평가 결과를 통해 전체 시스템의 가용성을 입증한다. 또한 인덱스 관리 기법, 트랜잭션 처리 기법, 이중화 관리 기법 등의 각 설계 요소 기법에 대하여 기존 다른 기법과의 성능 비교를 통해 설계에 적용된 요소기술의 우수성을 입증한다.

  • PDF

태양광 발전 이상감지를 위한 아웃라이어 추정 방법에 대한 연구 (A study on the outlier data estimation method for anomaly detection of photovoltaic system)

  • 서종관;이태일;이휘성;박점배
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.403-408
    • /
    • 2020
  • 태양광 발전은 특성상 간헐성과 불확실성이 항상 존재하기 때문에 정확한 예측은 어려우며, 실시간 발전량 진단을 위한 이상감지 기술이 중요하다. 본 논문에서는 다양한 파라미터의 상관관계를 도출하고 최근접 이웃 알고리즘을 적용하여 정상데이터와 비정상데이터를 분류한다. 두 분류의 결과는 발전 시스템의 결함에 의한 아웃라이어와 구름 등에 의해 단기간 동안 발생하는 부분 음영 및 전체 음영의 일시적인 전력손실을 보여준다. 100kW 발전소 데이터를 대상으로 머신러닝 분석을 수행하여 테스트 결과를 산출하였으며 실제 이상치와 이상치 후보지를 검증하였다.