• Title/Summary/Keyword: Short Fault

Search Result 531, Processing Time 0.026 seconds

Experimental Study on the Explosion and Fire Risks of Mobile Phone Batteries (휴대폰 배터리의 폭발 및 화재 위험성에 관한 실험적 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.111-120
    • /
    • 2016
  • This is an experimental study to analyze the explosion and fire hazards of mobile phone batteries. Using the lithium-ion batteries currently used on smart phone as the experiment samples, the experiments were conducted by overcharging, internal and external short circuit, and thermal shock with the potential of explosion and fire caused by careless use or abnormal conditions. The experiment results showed that, in the case of overcharging and external short circuit, there was no explosion and fire hazard in the normal operation of the protection circuit module (PCM), but there were big risks when the PCM faulted conditions were assumed. In the case of the experiments by internal short circuit and thermal shock, such risks varied depending on a battery charge state. In other words, it could be verified that there were low risks of explosion and fire in a full discharge state, but there were high risks in a full charge state. These experiment results suggest that to minimize the explosion and fire hazards of mobile phone batteries, an alarm device is necessary when the PCM fault occurs. In addition, a solid battery case should be made and safety equipment, such as a cooling device to avoid high temperature, is needed.

Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System (고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is confirmed the unreliability of the existing RCD by electrical fault simulator and is proposed a Electrical Fire Disaster Prevention Device (EFDPD) by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the EFDPD has double protection function which operates self circuit breaker or rapidly cuts off the existing RCD. The proposed EFDPD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise (온도상승에 따른 배선용 차단기의 동작특성에 관한 연구)

  • Jung, Da-Woon;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

An Efficiency Testing Algorithm for Realistic Faults in Dual-Port Memories (이중 포트 메모리의 실제적인 고장을 고려한 효율적인 테스트 알고리즘)

  • Park, Young-Kyu;Yang, Myung-Hoon;Kim, Yong-Joon;Lee, Dae-Yeal;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.2
    • /
    • pp.72-85
    • /
    • 2007
  • The development of memory design and process technology enabled the production of high density memory. However, this increased the complexity of the memory making memory testing more complicated, and as a result, it brought about an increase in memory testing costs. Effective memory test algorithm must detect various types of defects within a short testing time, and especially in the case of port memory test algorithm, it must be able to detect single port memory defects, and all the defects in the dual port memory. The March A2PF algorithm proposed in this paper is an effective test algorithm that detects all types of defects relating to the duel port and single port memory through the short 18N test pattern.

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Seismic risk estimation of the Kirikkale province through street survey based rapid assessment method (SSRA)

  • Sonmezer, Yetis Bulent;Bas, Selcuk;Akbas, Sami Oguzhan
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.615-626
    • /
    • 2018
  • The seismic vulnerability of Turkey is relatively high due to its active fault systems with potential to create destructive earthquakes. Thus, reducing the loss of life and property, the number of the earthquake-prone buildings and their retrofit requirements are considerably significant key issues under the scenario earthquakes. The street survey based rapid assessment (SSRA) method can be considered as a powerful tool to determine the seismic vulnerability of building stock of an earthquake-prone city/state. In this study, the seismic vulnerability of the building stock of the Kirikkale province in Turkey is aimed to be estimated adopting the street survey based rapid assessment method (SSRA). For this purpose, central 2074 existing reinforced concrete (R/C) buildings were structurally surveyed with rapid visual site screening and disadvantages such as, the existence of short-column, soft-story, heavy overhangs, pounding effect and local soil conditions were determined for obtaining the structural performance score of each. The results obtained from the study demonstrate that 11-25% of the surveyed buildings in the study region needs to be investigated through more advanced assessment methods. Besides, higher correlation between increasing story number and unsafe/safe building ratio is obtained for the buildings with soft-story parameter than that for those with heavy overhangs and short-column parameters. The conformity of the results of the current study with the previous documented cases of rapid assessment efforts in the recent earthquakes in Turkey shows that the SSRA method for the Kirikkale province performed well, and thus this methodology can be reliably used for similar settlement areas.

Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock (전철 탑재용 피뢰기의 설계 및 성능평가)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.;Kim, S.S.;Chang, T.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

A Study on Constructing the RCM-based Failure Analysis System for Railway Facilities & Equipments (RCM 기반 철도시설물 고장분석시스템 구축 - 서울메트로 -)

  • Jung, Kwan-Soo;Seo, Kwang-Hyuk;Lee, Jung-Joo;Nam, Jin-Geun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.881-895
    • /
    • 2011
  • Seoul Metro railway facilities' inspection and maintenance tasks cause failure analysis, but if there is trouble the diverse cause investigation and the systematic analysis and management among broken facilities, related facilities and components fell short and the conditions are different. And, excess and insufficiency, under inspection and maintenance, is being raised regardless of the introduction year and the operating environment including the number of use by applying the same facilities in the uniform inspection cycle. In this study, we will analysis systematically facility system information, failures, operational status, performance, fault and maintenance information resulting from the maintenance management of railway facilities and derive the relationship between associated equipment and its components. In addition, optimizing the inspection and the maintenance cycles of railway facilities, we will improve the reliability of operation. Considering the probability of risk, it is possible to predict the occurrence of accidents or faults and to minimize the frequency of breakdown by pre-inspection maintenance. Finally, This paper is to introduce the content of constructing the Seoul Metro RCM-based failure analysis system for railway facilities to support the optimal continuance of operation status of equipments and the securement of the safe operation of vehicles.

  • PDF

Wing Technique: A Novel Approach for the Detection of Stator Winding Inter-Turn Short Circuit and Open Circuit Faults in Three Phase Induction Motors

  • Ballal, Makarand Sudhakar;Ballal, Deepali Makarand;Suryawanshi, Hiralal M.;Mishra, Mahesh Kumar
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.208-214
    • /
    • 2012
  • This paper presents a novel approach based on the loci of instantaneous symmetrical components called "Wing Shape" which requires the measurement of three input stator currents and voltages to diagnose interturn insulation faults in three phase induction motors operating under different loading conditions. In this methodology, the effect of unbalanced supply conditions, constructional imbalances and measurement errors are also investigated. The sizes of the wings determine the loading on the motor and the travel of the wings while their areas determine the degree of severity of the faults. This approach is also applied to detect open circuit faults or single phasing conditions in induction motors. In order to validate this method, experimental results are presented for a 5 hp squirrel cage induction motor. The proposed technique helps improve the reliability, efficiency, and safety of the motor system and industrial plant. It also allows maintenance to be performed in a more efficient manner, since the course of action can be determined based on the type and severity of the fault.

Improvement of Short Circuit Performance in 460[V]/400{A]/85(kA] Molded Case Circuit Breakers (460[V]/400[A]/85[kA] 배선용 차단기의 아크런너 변형을 통한 차단성능 향상)

  • Lee, Seung-Su;Her, June;Yoon, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.394-394
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker(hereafter MCCB) depends on the shape, arrangement, and kinds of material of arc runner. This paper is focused on understanding the interrupting capability, more specifically of the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF