• Title/Summary/Keyword: Shock wave.

Search Result 982, Processing Time 0.034 seconds

Assessment of the Counter-Flow Thrust Vector Control in a Three-Dimensional Rectangular Nozzle (3차원 직사각형 노즐에서 역유동 추력벡터 제어 평가)

  • Wu, Kexin;Kim, Tae Ho;Kochupulickal, James Jintu;Kim, Heuy Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.1
    • /
    • pp.34-46
    • /
    • 2020
  • Computational assessment of gas-dynamic characteristics is explored for a three-dimensional counter-flow thrust vector control system in a rectangular supersonic nozzle. This convergent-divergent nozzle is designed by Method of Characteristics and its design Mach number is specially set as 2.5. Performance variations of the counter-flow vector system are illustrated by varying the gap height of the secondary flow duct. Key parameters are quantitatively analyzed, such as static pressure distribution along the centerline of the upper suction collar, deflection angle, secondary mass flow ratio, and resultant thrust coefficient. Additionally, the streamline on the symmetry plane, three-dimensional iso-Mach number surface contour, and three-dimensional turbulent kinetic energy contour are presented to reveal overall flow-field characteristics in detail.

레이저 유기 충격파를 이용한 나노 Trench 에서의 나노입자제거

  • Kim, Jin-Su;Lee, Seung-Ho;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.25.1-25.1
    • /
    • 2009
  • Pattern 웨이퍼 상의 오염입자 제거는 반도체 산업의 주된 과제 중 하나이다. Pattern의 선폭이 좁아짐에 따라 Pattern에 손상을 가하지 않고 오염입자를 제거 하는 것은 더욱 어려워지고 있다. 그뿐만 아니라 기존 습식세정 공정에서의 화학액에 의한 환경오염 및 박막의 손실도 문제가 되기 시작했다. 이러한 문제를 해결하기 위해 기존 세정공정에서 화학액의 농도를 낮추고 Megasonic 등을 이용하여 세정력을 보완하는 방법들이 연구되고 있다. 하지만 습식세정의 경우 강한 화학작용으로 인한 표면 손상 및 물 반점의 문제는 여전히 이슈가 되고 있다. 이러한 단점을 극복하기 위하여 건식 세정법이 제시되고 있으며 이 중 레이저 충격파는 레이저를 집속시켜 발생된 충격파를 이용하여 입자를 제거하기 때문에 국부적인 세정이 가능하며 세정력 조절이 가능하여 손상이 세정을 할 수 있다. 그러나 Pattern의 구조에 의해 전되는 세정력의 차이가 발생하고 Trench 내부의 오염입자제거 문제점이 발생할 수 있다. 시편은 Si STI Pattern을 100 nm PSL Particle (Red Fluorescence, Duke Scientific, USA) 을 50ppm 농도로 희석시킨 IPA에 dipping 하여 오염시킨 후 N2 Gas를 이용하여 건조하여 준비하였다. 그리고 레이저 충격파 세정 시스템은 최대 에너지 1.8 J까지 가능한 레이저를 발생하는 1,064 nm Nd:YAG 레이저를 이용하여 실험하였다. 레이져 충격파 실험은 충격파와 시편사이의 거리, gap distance와 에너지를 변환하여 세정효율을 관찰하였다. 세정효율은 세정 전후의 입자 감소량을 현광현미경 (LV-150, Nikon, Japan)를 이용하여 측정하였다. 그 결과, Trench 내부의 오염입자의 경우 Trench 밖의 오염입자에 비해 세정효율이 떨어지는 것으로 나타났으나 시편과 레이저 초점과의 거리가 가까워짐에 따라 Trench 내부의 오염입자에 대한 세정 효율을 증가시킬 수 있었다.

  • PDF

Protective Effect of Quercus salicina Blume Extract in Calcium Oxalate Urolithiasis Model (참가시나무 추출물이 신장결석유도 랫드에 미치는 저해효과)

  • Heo, Jin-Sun;Kim, Jong-Bok;You, Han-Choon;Lee, Min-Su;Choi, Jong-Won
    • Korean Journal of Plant Resources
    • /
    • v.25 no.5
    • /
    • pp.507-516
    • /
    • 2012
  • Kidney stones occur in approximately 1% of the population during their lifetime. Although the development of extracorporeal shock wave lithotripsy (SWL) has revolutionized the theraphy of urolithiasis, the rate of recurrence of urothiasis, the rate of recurrenece of stones after SWL is about 50% within 10 years, which still represents serious problems for patienes. So to clarify the mechanism of Urocalum, and QS (Quercus salicina Blume) extract in the treatment of urolithiasis. Rat calcium oxalate urolithiasis was induced by oral administration of ethylene glycol and the vitamin D3 analog alfacalcidol for 14 days and QS extract was given to rats. After the last administration, we measured in urine, serum and renal oxidative stress marker. Ethylene glycol and alfacalcidol treatment increased BUN, creatinine, uric acid and XO. This increase was significantly suppressed by the administration of QS extract. These finding suggest that the QS extract plays a role in the prevention of stone formation and recureence in urolithiasis.

Processing the Data from the uTSN of Uninterrupted Traffic Flow (연속류 uTSN 수집 데이터 가공 방안)

  • Park, Eun-Mi;Suh, Euy-Hyun
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.1
    • /
    • pp.57-69
    • /
    • 2010
  • The ubiquitous transportation system environments make it possible to collect each vehicle's position and velocity data and to perform more sophisticated traffic flow management at individual vehicle or platoon level through V2V and V2I communication. It is necessary to develop a new data processing methodology to take advantage of the ubiquitous transportation system environments. This paper proposed to build 3-dimension data profiles to maintain the detailed traffic flow information contained in the individual vehicles' data and at the same time to keep the profiles from the meaningless fluctuations. Also methods to build the platoon profile and the shock wave speed profile are proposed, which have not been possible under ITS(Intelligent Transportation System) environments.

Characteristics of Damage on Photosensor Irradiated by Intense Illumination : Thermal Diffusion Model (고섬광에 노출된 광센서의 손상 특성 : 열확산 모델)

  • Kwon, Chan-Ho;Shin, Myeong-Suk;Hwang, Hyon-Seok;Kim, Hong-Lae;Kim, Seong-Shik;Park, Min-Kyu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.201-207
    • /
    • 2012
  • Pulsed lasers at the 613 nm and 1064 nm wavelengths on nanoseconds have been utilized to characterize the damage on Si photodiode exposed to intense illumination. Morphological damages and structural changes at sites on the photodiode irradiated during microseconds of laser pulses were analyzed by FE-SEM images and XRD patterns, respectively. The removal of oxide coating, ripple, melting marks, ridges, and crater on photodiodes were definitely observed in order of increasing the pulse intensities generated above the damage threshold. Then, the degradation in photosensitivity of the Si photodiode irradiated by high power density pulses was measured as a function of laser irradiation time at the various wavelengths. The free charge carrier and thermal diffusion mechanisms could have been invoked to characterize the damage. The relative photosensitivity data calculated using the thermal diffusion model proposed in this paper have been compared with the experimental data irradiated above the damage threshold.

Analysis of Shielding Characteristics for Induction Phenomenon Attenuation of Large Capacity Wireless Power Transmission Environment (대용량 무선전력전송 환경 유도현상 감쇄를 위한 차폐 특성 분석)

  • Chae, Dong-Ju;Kim, Young-Seok;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo;Hong, Seong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1844-1851
    • /
    • 2017
  • As the capacity of the wireless power transmission increases, a higher supply current which may induce current in nearby conductive parts requires. Induced current may affect electric shock to the human body and malfunction of the electrical equipment. In order to prevent such induced phenomena as a risk factor, shielding is required between the source of the wireless power transmission and the conductive parts. The resonance frequency for the large capacity wireless power transmission has the wavelength of several hundred meters, so most environments are included in the near-field area. By wave impedance, the electric field has higher density in the near-field area and needs to be analyze for protecting. For this purpose, it is necessary to select a substance having a larger electric conductivity and optimized shielding structure. In this paper, an aluminum base shielding structure was presented to conduct experiments on thickness, position, and heat dissipation. In the 35 kW, 60 kHz environments, the optimized 5T Al base shielding structure attenuates the induced current to 43 %.

Inverter type High Efficency Neon Transformers for Neon Tubes (인버터식 고효율 네온관용 변압기)

  • 변재영;김윤호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.22-29
    • /
    • 2002
  • The conventional neon transformer systems are very bulky and heavy because it consist of leakage type transformers made of silicon steel plates. In addition, it has problems in noise by a neon transformer and in possibilities of fire and electrical shock when neon tubes are destroyed. A protection circuit is designed for all types of neon transformer loaded with one or more neon tubes. Whenever the neon tube fails to be started up, comes to the life end, encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. To improve such problems, in this paper, a new type of neon power supply systems for neon tube is designed and implemented using inverter type circuits and a newly designed lightweight transformer. In the developed neon transformer system, a 60[Hz]power input is converted to 20[KHz]high frequency using half-wave inverters, thereby the transformer reduces its size by 1/5 in volume and 1/10 in weight.

TRANSFORMER EXPLOSION AND FIRE PREVENTION (변압기 폭발/화재 방지 기술)

  • Kim, Hyung-Seung;Magnier, Philippe
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

A Study of the Thrust Vectoring Control Using Secondary Co- and Counter-Streams (2차 순유동과 역유동을 이용한 추력벡터 제어법에 관한 연구)

  • Lim Chae-Min;Kim Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.109-112
    • /
    • 2004
  • Of late, the thrust vectoring control, using fluidic co-flow and counter-flow concepts, has been received much attention since it not only improves the maneuverability of propulsive engine but also reduces an additional material load due to the trailing control wings, which in turn reduce the aerodynamic drag. However, the control effects are not understood well since the flow field involves very complicated non: physics such as shock wave/boundary layer interaction, separation and significant unsteadiness. Existing data are not enough to achieve the effectiveness and usefulness of the thrust vectoring control, and systematic work is required for the purpose of practical applications In the present study, computational study has been performed to investigate the effects of the thrust vector control using the fluidic co-and counter-flow concepts. The results obtained show that, for a given pressure ratio, the thrust deflection angle has a maximum value at a certain suction flow rate, which is at less than $5\%$ of the mass flow rate of the primary jet. With a longer collar, the same vector angle is achievable with smaller mass flow rate.

  • PDF

Experimental Study on a Two-Stage Light-Gas Gun (2단 경가스총에 대한 실험적 연구)

  • Lee, Jung-Keun;Kim, Heuy-Dong;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.10-15
    • /
    • 2010
  • Light gas guns have a large number of applications in various fields of engineering. A two-stage light-gas gun can produce an extremely high pressure in a very short interval of time. In general, the two-stage light-gas gun is made up of a high pressure tube, a compression tube and a launch tube, each stage being separated by diaphragms. This can be employed efficiently in the application of ultra-high pressure liquid jets. In the present study, experiments are carried out to investigate the projectile velocity and pressure behavior in the tubes according to the pressure changes at the frist diaphragm opening. In the present study result was found that the rupture pressure of the first diaphragm has a dominant influence on piston acceleration.