• Title/Summary/Keyword: Shock wave.

Search Result 984, Processing Time 0.027 seconds

Study on Flow Characteristics and Discharge Coefficient of Safety Valve for LNG/LNG-FPSO Ships (LNG / LNG-FPSO 선박용 안전밸브의 유동특성 및 유출계수에 관한 연구)

  • Kim, Sung-Jin;Jung, Sung-Yuen;Kim, Dang-Ju;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.487-494
    • /
    • 2011
  • The safety valve used in LNG/LNG-FPSO ships plays an important role in maintaining a fixed level of pressure by emitting LNG gas out of the pipes in the LNG piping system. The discharge coefficient is regarded as the most important factor in the valve performance. To satisfy the ship's classification, the discharge coefficient of the safety valve must usually be over 0.8. Despite the importance of understanding the flow phenomena inside the safety valve, the valve design is usually based on experience and experiments. We carried out a computational fluid dynamics (CFD) investigation using the ANSYS-CFX software. We observed the flow phenomena inside the valve and measured the discharge coefficients according to changes in the valve lift, which is the distance between the exit of the nozzle and the lower part of the disc plate. We verified our CFD results for the discharge coefficients using available experimental data.

Study of the Supersonic Ejector-Diffuser System with a Mixing Guide Vane (혼합 안내깃을 적용한 초음속 이젝터-디퓨져 시스템에 대한 연구)

  • Kong, Fanshi;Jin, Yingzi;Kim, Heuydong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.52-60
    • /
    • 2013
  • Ejector-diffuser system makes use of high-pressure primary stream to entrain the low-pressure secondary stream through pure shear action between two streams. In general, the flow field in the ejector-diffuser system is highly complicated due to turbulent mixing, compressibility effects. A fatal drawback of the ejector system is in its low efficiency. Many works have been done to improve the performance of the ejector system, but not yet satisfactory. In the present study, a mixing guide vane was installed at the inlet of the secondary stream for the purpose of the performance improvement of the ejector system. A CFD method has been applied to simulate the supersonic flows inside the ejector-diffuser system. The present results obtained were validated with existing experimental data. The mixing guide vane effects are discussed in terms of the entrainment ratio, total pressure loss as well as pressure recovery.

Analytical Study on the Gas-Solid Suspension Flows through Sonic and Supersonic Nozzles (음속 및 초음속 노즐을 통한 Gas-Solid Suspension 유동에 대한 해석적 연구)

  • Sun, JianGuo;Rajesh, G.;Kim, Heuydong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2013
  • A considerable deal of work has been carried out to get an insight into the gas-solid suspension flows and to specify the particle motion and its influence on the gas flow field. In this paper an attempt is made to develop an analytical model to study the effect of nozzle inlet/exit pressure ratio, particle/gas loading and the particle diameter effect on gas-solid suspension flow. The effect of the particle/gas loading on the mass flow, Mach number, thrust coefficient and static pressure variation through the nozzle is analyzed. The results obtained show that the presence of particles seems to reduce the strength of the shock wave. It is also found that smaller the particle diameter is, bigger will be the velocity as bigger particle will have larger slip velocity. The suspension flow of smaller diameter particles has almost same trend as that of single phase flow with ideal gas as working fluid. Depending on the ambient pressure, the thrust coefficient is found to be higher for larger particle/gas loading or back pressure ratio.

A Study on the Transmitter Design for Transmitting Output Power Enhancement of Active Magnetic Sensor (능동형 자기센서의 송신출력 향상을 위한 송신기 설계에 관한 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Jeon, Jae-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.5
    • /
    • pp.159-165
    • /
    • 2013
  • A active magnetic sensor has been widely used in the underwater guided weapon system because it is able to detect a target accurately in close range, but the target doesn't have any good countermeasure to overcome the threat from the active magnetic sensor. Recently, in order to increase the damage area of target by shock wave with explosion of the underwater weapon system and to detect small target, the maximum target detection range of the active magnetic sensor needs to be increased. One method for improving maximum target detection range is to improve output power from transmitter through demagnetization factor minimization of a transmitting core. Thus, in this paper, we describe the study results on the transmitter core shape design to enhance output power of the active magnetic sensor.

The Effect of Different Particle Size from PAHs Contaminated Sediment by Ultrasonic Irradiation (PAHs로 오염된 침전물의 초음파 처리시 입자크기가 미치는 영향)

  • Na, Seung-Min;Khim, Jee-Hyeong;Cui, Ming-Can;Ahn, Yun-Gyong;Weavers, Linda K.
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.379-387
    • /
    • 2010
  • Sediments of Little Scioto (LS) River in Ohio was contaminated by poor disposal of creosote from Baker Wood Creosoting Facility. Among the primary compounds of creosote, Polycyclic Aromatic Hydrocarbons (PAHs) are the most common ingredient PAHs are known for toxic, carcinogenic and mutagenic compounds. There are many difficulties to remove the PAHs in nature environment because their characteristics are having a less water-solubility, volatile and low mobility properties as increasing the molecular weight. The generation of hydroxyl radicals (${\cdot}OH$) and hydrogen peroxide ($H_2O_2$) forms as well as high temperature (5000 K) and pressure (1000 atm) by a physico-chemical effects of ultrasound during a cavitation collapse can promote the degradation and desorption of PAHs in sediment And it can also produces shock wave and microjets which are able to change the size and surface of particle in solid-liquid system as one of physical effects. Therefore, we explored to understand the role of particle size, the effect of elimination for PAHs concentration by ultrasound and optimize the conditions for ultrasonic treatment. The condition of various size of particles (> $150{\mu}m$, < $150{\mu}m$) and solid-liquid ratio (12.5g/L, 25g/L) for the treatment was considered and ultrasonic power (430 W/L) with liquid - hexane extraction and microwave extraction method were applied after ultrasound treatment.

Efficiency and Power Factor Improvement of Induction Motor Using Single-Phase Back Rectifier (단상 강압 정류기를 이용한 유도전동기의 효율 및 역률 개선)

  • 문상필;이현우;서기영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.22-29
    • /
    • 2002
  • Usually, much harmonics are included and cause harmonic loss of motor, torque pulsation, electro-magnetic noise and shock etc. by switching function of inverter when drive induction motor variableness inside. It applied partial resonant Buck converter and three phase voltage type SPWM inverter circuit to induction motor driving system in this paper that see to solve such problem. Changed operation condition variously to do input current of circuit that propose sine-wave by unit power factor almost and capacitor supplied bringing back to life voltage by power supply arranging properly assistance diode and electric power switching. Power factor and efficiency improved as that minimize variation of input at power supply voltage polarity reverse by that add voltage reversal function. Also, by using output filter, reduced harmonic of output line to line voltage components, and introduce state space analysis and forecast operation of rectifier. Such all items confirmed validity through simulation and an experiment.

The development for flooding prevention apparatus of electrical equipment using air pressure (공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Jean, Hyun-Jae;Lee, Sang-Ick;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

Aerodynamic Characteristics of the Grid Fins on SpaceX Falcon 9 (SpaceX Falcon 9 그리드핀의 공력 특성)

  • Lee, HyeongJin;Cho, WooSung;Ko, SangHo;Lee, Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.745-752
    • /
    • 2020
  • A numerical study was carried out to evaluate the aerodynamic characteristics of the supersonic grid fins installed on SpaceX Falcon 9. The unit-grid-fin concept was utilized for more efficient and simpler 3-D steady flow calculations. Pre- and post-correction processes that accounted the interference effects by the angle of attack of the missile, the influences of the outer frame of the grid fin and the connecting rods were improved in the study, and it was demonstrated that the present correction method was more accurate as compared to previous studies. Finally, the present approach was applied to evaluate the aerodynamic characteristics in transonic/supersonic flights of SpaceX Falcon 9 with various angle of attacks.

Laser Patterning of Vertically Grown Carbon Nanotubes (수직성장된 탄소나노튜브의 선택적 패터닝)

  • Chang, Won Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1171-1176
    • /
    • 2012
  • The selective patterning of a carbon nanotube (CNT) forest on a Si substrate has been performed using a femtosecond laser. The high shock wave generated by the femtosecond laser effectively removed the CNTs without damage to the Si substrate. This process has many advantages because it is performed without chemicals and can be easily applied to large-area patterning. The CNTs grown by plasma-enhanced chemical vapor deposition (PECVD) have a catalyst cap at the end of the nanotube owing to the tip-growth mode mechanism. For the application of an electron emission and biosensor probe, the catalyst cap is usually removed chemically, which damages the surface of the CNT wall. Precise control of the femtosecond laser power and focal position could solve this problem. Furthermore, selective CNT cutting using a femtosecond laser is also possible without any phase change in the CNTs, which is usually observed in the focused ion beam irradiation of CNTs.