• Title/Summary/Keyword: Shielding simulation

Search Result 226, Processing Time 0.024 seconds

Analysis for shielding effectiveness of a satellite electronic equipment enclosure with a dielectric-backed aperture (유전체로 막힌 개구를 갖는 위성 전자 장비 함체의 차폐 효과 해석)

  • Kim, Su-Han;Lee, Jae-Hyun
    • Journal of Satellite, Information and Communications
    • /
    • v.3 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • In this paper, a new analytical formulation is presented for calculating shielding effectiveness (SE) of shielding enclosure including satellite electronic components and equipments. The shielding enclosure has a dielectric-backed aperture. The SE may be a function of frequency, dielectric constant, and position within the enclosure. And, the formulation has been extended for calculation of the SE of the structure where the one side of dielectric is partially backed by conductor. Our simulation results give that the dielectric material lowers the Q factor, and the further the observation point is from the aperture, the more SE increases.

  • PDF

An analysis of new IGBT(Insulator Gate Bipolar Transistor) structure having a additional recessedwith E-field shielding layer

  • Yu, Seung-Woo;Lee, Han-Shin;Kang, Ey-Goo;Sung, Man-Young
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.247-251
    • /
    • 2007
  • The recessed gate IGBT has a lower on-state voltage drop compared with the DMOS IGBT, because there is no JFET resistance. But because of the electric field concentration in the corner of the gate edge, the breakdown voltage decreases. This paper is about the new structure to effectively improve the Vce(sat) voltage without breakdown voltage drop in 1700V NPT type recessed gate IGBT with p floating shielding layer. For the fabrication of the recessed gate IGBT with p floating shielding layer, it is necessary to perform the only one implant step for the shielding layer. Analysis on the Breakdown voltage shows the improved values compared to the conventional recessed gate IGBT structures. The result shows the improvement on Breakdown voltage without worsening other characteristics of the device. The electrical characteristics were studied by MEDICI simulation results.

  • PDF

Evaluation of the Effectiveness of 3D Printing Shielding Devices using Monte Carlo Simulation in Plain Radiography (일반영상 검사 시 몬테칼로 시뮬레이션을 이용한 3D 프린팅 차폐기구의 효용성 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.303-311
    • /
    • 2020
  • Scattering-ray generated during plain radiography can cause secondary exposure to organs and tissues other than the target area. Currently, Shielding devices used to reduce radiation exposure are mostly used for radiation protection of workers, and radiation protection of patients is rarely performed. Therefore, this study intends to evaluate the organ dose by scattered-rays and the effectiveness 3D printing materials as a radiation shielding device during plain radiography through simulation. As a result, the absorbed dose for each organ at the time of examination showed a high effect due to the secondary scattering-ray as the distance from the source was close and the organ closer to the skin surface. The dose reduction effect due to the use of 3D printing shielding devices to protect this showed a higher shielding effect in the case of mixed printing materials compared to plastics.

Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation (MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가)

  • Yang, Seung u;Park, Geum-byeol;Heo, Ye Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.367-373
    • /
    • 2020
  • Most of the spatial scattered dose caused by the scattered rays generated by the collision between the object and X-rays is relatively easily absorbed by the human body as electromagnetic waves in the low energy region, thereby increasing the degree of radiation exposure. Such spatial scattering dose is also used as an indicator of the degree of radiation exposure of radiation workers and patients, and there is a need for a method to reduce exposure by reducing the spatial scattered dose that occurs indirectly. Therefore, in this study, a lead-free radiation shielding sheet was proposed as a way to reduce the spatial scattering dose, and a Monte Carlo (MC) simulation was performed based on a chest X-ray examination. The absorbed dose was calculated and the measured value and the shielding rate were compared and evaluated.

Evaluation of Shielding Performance of Tungsten Containing 3D Printing Materials for High-energy Electron Radiation Therapy (고에너지 전자선 치료 시 텅스텐 함유 3D 프린팅 물질의 차폐 성능 평가)

  • Yong-In Cho;Jung-Hoon Kim;Sang-Il Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.641-649
    • /
    • 2023
  • This study compares and analyzes the performance of a shield manufactured using 3D printing technology to find out its applicability as a shield in high-energy electron beam therapy. Actual measurement and monte carlo simulations were performed to evaluate the shielding performance of 3D printing materials for high-energy electron beams. First, in order to secure reliability for the simulation, a source term evaluation was conducted by referring to the IAEA's TRS-398 recommendation. Second, to analyze the shielding performance of PLA+W (93%), a specimen was manufactured using a 3D printer, and the shielding rate by thickness according to electron beam energy was evaluated. Third, the shielding thickness required for electron beam treatment was calculated through a comparative analysis of shielding performance between PLA+W (93%) and existing shielding bodies. First, as a result of the evaluation of the source term through actual measurement and simulation, the TRS-398 recommendation was satisfied with an error of less than 1%, thereby securing the reliability of the simulation. Second, as a result of the shielding performance analysis for PLA+W (93%), 6 MeV electron beams showed a shielding rate of more than 95% at 3.12 mm, and 15 MeV electron beams showed a shielding rate of more than 90% at 10 mm thickness. Third, through simulations, comparative analysis between PLA+W (93%) materials and existing shields showed high shielding rates within the same thickness in the order of tungsten, lead, copper, PLA+W (93%), and aluminum. 6 MeV electron beams showed almost similar shielding rates at 5 mm or more and 15 MeV electron beams. Through this study in the future, it is judged that it can be used as basic data for the production and application of shielding bodies using PLA+W (93%) materials in high-energy electron beam treatment.

Barium Compounds through Monte Carlo Simulations Compare the Performance of Medical Radiation Shielding Analysis (몬테카를로 시뮬레이션을 통한 바륨화합물의 의료방사선 차폐능 비교 분석)

  • Kim, Seonchil;Kim, Kyotae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.403-408
    • /
    • 2013
  • This study made a tentative estimation of the shielding rate of barium compound by thickness through monte carlo simulation to apply medical radiation shielding products that can replace existing lead. Barium sulfate($BaSO_4$) was used for the shielding material, and thickness of the shielding material specimen was simulated from 0.1 mm to 5 mm by applying $15{\times}15cm^2$ of specimen area, $4.5g/cm^3$ of density of barium sulfate, and $11.34g/cm^3$ density of lead. Entered source was simulated with 10kVp Step in consecutive X-ray energy spectrum(40 kVp ~ 120 kVp). Absorption probability in 40 kVp ~ 60 kVp showed same shielding rate with lead in 3 mm ~ 5 mm of thickness, but it was identified that under 2 mm, the shielding rate was a bit lower than the existing lead shielding material. Also, the shielding rate in 70 kVp ~ 120 kVp energy band showed similar performance as the existing lead shielding material, but it was tentatively estimated as fairly low shielding rate below 0.5 mm. This study estimated the shielding rate of barium compound as the thickness function of x-ray energy band for medical radiation through monte carlo simulation, and made comparative analysis with existing lead. Also, this study intended to verify application validity of the x-ray shielding material for medical radiation of pure barium sulfate. As a result, it was estimated that the shielding effect was 95% higher than the existing lead 1.5 mm in at least 2 mm thickness of barium compound in medical radiation energy band 70 kVp ~ 120 kVp, and this result is considered valid to be provided as a base data in weight lightening production of radiation shielding product for medical radiation.

Assessment of Radiation Shielding Ability of Printing Materials Using 3D Printing Technology: FDM 3D Printing Technology (3D 프린팅 기술을 이용한 원료에 대한 방사선 차폐능 평가: FDM 방식의 3D 프린팅 기술을 중심으로)

  • Lee, Hongyeon;Kim, Donghyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.909-917
    • /
    • 2018
  • 3D printing technology is expected to be an innovative technology of the manufacturing industry during the 4th industrial revolution, and it is being used in various fields including biotechnology and medical field. In this study, we verified the printing materials through Monte Carlo simulation to evaluate the radiation shielding ability of the raw material using this 3D printing technology. In this paper, the printing materials were selected from the raw materials available in a general-purpose FDM-based 3D printer. Simulation of the ICRU phantom and the shielding system was carried out to evaluate the shielding effect by evaluating the particle fluence according to the type and energy of radiation. As a result, the shielding effect tended to decrease gradually with increasing energy in the case of photon beam, and the shielding effect of TPU, PLA, PVA, Nylon and ABS gradually decreased in order of materials. In the case of the neutron beam, the neutron intensity increases at a low thickness of 5 ~ 10 mm. However, the effective shielding effect is shown above a certain thickness. The shielding effect of printing material is gradually increased in the order of Nylon, PVA, ABS, PLA and TPU Respectively.

SIMULATION OF SHIELDING EFFECTS ON THE TOTAL DOSE OBSERVED IN TDE OF KITSAT-1 (KITSAT-1 TDE의 차폐 효과에 의한 총 축적 방사능양 변화에 대한 연구)

  • 김성준;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.71-80
    • /
    • 2001
  • The threshold voltage shift observed in TDE (Total Dose Experiment) on board the KITAT-1 is converted into dose (rad($SiO_2$)) using the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute). Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  • PDF

Analysis of Lighting Overvoltage and Shielding Effect of Overhead Ground Wire on the DC Railway (직류 전차선로의 뇌과전압 해석 및 가공지선 차폐효과 검토)

  • Jung, Che-Kyun;Hong, Dong-Suk;Lee, Jong-Beom;Cho, Han-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.165-167
    • /
    • 2000
  • This paper presents the influence of the lightning overvoltage and the shielding effects of overhead grounding wire on the DC railway system. Modeling of Railway system is established in ATPDraw to perform simulation. The result of simulation reveals that the shielding effects of overhead grounding wire has over 90% than the case which has not it. Therefore it is evaluated that overhead grounding wire should be installed in the DC railway line.

  • PDF

Impacts of halloysite clay nanoparticles on the structural and γ-ray shielding properties of the epoxy resin

  • K.G. Mahmoud;M.I. Sayyed;S. Hashim;Aljawhara H. Almuqrin;Abu El-Soad A.M
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1585-1590
    • /
    • 2023
  • In this study, halloysite nanoparticles-doped epoxy resin was synthesised using the casting method. The MH-300A density metre revealed that the density of the fabricated composites changed from 1.132 to 1.317 g/cm3 as the halloysite nanoparticle concentration increased. The Fourier transform infrared was recorded for the synthesised composites. Furthermore, the γ-ray shielding properties of the synthesised composites were evaluated using Monte Carlo simulation and a theoretical programme, XCOM. The linear attenuation coefficient of the epoxy resin increased by 43% (at γ-energy of 15 keV) and 14% (at γ-photon energy of 662 keV) when the concentration of the halloysite nanoparticles was increased from 0 wt% to 40 wt%, respectively.