• Title/Summary/Keyword: Shielding block

Search Result 68, Processing Time 0.024 seconds

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size (수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구)

  • Lee, Chang-Yeol;Son, Ki-Hong;Shin, Sang-Hun;Park, Seung-Woo;Lee, Dong-Han;Jung, Hai-Jo;Choi, Mun-Sik;Oh, Won-Young;Kim, Kum-Bae;Yang, Gwang-Mo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.3-11
    • /
    • 2011
  • The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.

A Study on Inter-leaf Transmission and Cross-leaf Transmission for Clinical Applications of the Multileaf Collimator (다엽 콜리메이터의 임상적용을 위한 엽측간 투과선량 및 엽종단간 투과선량 연구)

  • 이규찬;최진호
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • Multileaf collimator (MLC) is now rapidly replacing the lead ahoy block to shape the radiation treatment field. In addition to its defect of rectangular field shaping and increased penumbra width, it has another possible problem, and that is of radiation transmission between leaves, which needs to be maintained at as low a level as is permissible. The authors measured and analyzed the inter-leaf and cross-leaf transmissions of MLC by Varian Associates Inc, before its clinical application. The inter-leaf and cross-leaf transmissions were calculated by comparing the measured point doses in the polystyrene phantom in the open field and in a total closure of MLC. The beam profile of the inter-leaf and cross-leaf transmissions were depicted by using a water phantom. A photon beam of 6 MV was used in the measurement. The inter-leaf transmission was 1.63∼1.67%, indicating that the shielding effect of MLC is excellent. However, the cross-leaf transmission in the central area was 18.4∼18.7% and this is well over the clinically acceptable limitation of 5%. The beam profile of cross-leaf transmission displayed 80∼90% transmission near the field edge, so that the cross-leaf transmission was 14∼17% in this area. The multileaf collimator has an excellent shi디ding effect and the inter-leaf transmission is negligible so that it can be used in clinic as a good replacement of the conventional lead alloy block. However, care must be taken to avoid the cross-leaf transmission in the radiation field.

  • PDF

A Feasibility study on the Simplified Two Source Model for Relative Electron Output Factor of Irregular Block Shape (단순화 이선원 모델을 이용한 전자선 선량율 계산 알고리듬에 관한 예비적 연구)

  • 고영은;이병용;조병철;안승도;김종훈;이상욱;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • A practical calculation algorithm which calculates the relative output factor(ROF) for irregular shaped electron field has been developed and evaluated the accuracy of the algorithm. The algorithm adapted two-source model, which assumes that the electron dose can be express as sum of the primary source component and the scattered component from the shielding block. Original two-source model has been modified in order to make the algorithm simpler and to reduce the number of parameters needed in the calculation, while the calculation error remains within clinical tolerance range. The primary source is assumed to have Gaussian distribution, while the scattered component follows the inverse square law. Depth and angular dependency of the primary and the scattered are ignored ROF can be calculated with three parameters such as, the effective source distance, the variance of primary source, and the scattering power of the block. The coefficients are obtained from the square shaped-block measurements and the algorithm is confirmed from the rectangular or irregular shaped-fields used in the clinic. The results showed less than 1.0 % difference between the calculation and measurements for most cases. None of cases which have bigger than 2.1 % have been found. By improving the algorithm for the aperture region which shows the largest error, the algorithm could be practically used in the clinic, since one can acquire the 1011 parameter's with minimum measurements(5∼6 measurements per cones) and generates accurate results within the clinically acceptable range.

  • PDF

A Study on the Dose Changes Depending on the Shielding Block Type of Irradiation During Electron Beam Theraphy (전자선치료 시 조사부위 차폐물 형태에 따른 선량변화 연구)

  • Lee, Sun-Yeb;Park, Cheol-Soo;Lee, Jae-Seung;Goo, Eun-Hoe;Cho, Jae-Hwan;Kim, Eng-Chan;Moon, Soo-Ho;Kim, Jin-Soo;Park, Cheol-Woo;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • The primary focus of this study was to explore the variation in dose distributions of electron beams between different types of construction structure of cut-out blocks embodied in electron cones, given that the structure is considered one of the causes of multiple scattered radiation from electrons which may affect dose distributions. For evaluation, two types of cut-out blocks, divergency and straight, manufactured for this study, were compared in terms of area of interval in distribution of dose, and flatness and symmetric state of surface being radiated. The results showed that divergency cut-out blocks reduced the lateral scattering effects on the thickness of cut-out blocks more substantially than straight ones, leading to more uniform dose distribution at baseline depth. Notably in divergency cut-out blocks, the high dose area decreased more significantly, and more uniform dose distribution was observed at the edge of the irradiated field. This points to a need to consider the characteristics of dose distribution of electron beams when setting up radiotherapy planing at the venues. Therefore, this study is significant as an exploratory work for ensuring high accuracy in dose delivery for patients.

Biosensing interfaces based on the dendrimer-underlying layer on gold

  • Yun, Hyeon-Cheol;Kim, Hak-Seong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.52-55
    • /
    • 2000
  • Structually organized mono- and multilayers were developed on gold for the catalytic and affinity biosensing using hyper-branched dendrimers. For the catalytic biosensing interface, a new approach to construct a multilayered enzyme film on the electrode surface was developed. The film was prepared by layer-by-layer depositions of dendrimers and periodate-oxidized glucose oxidase. The voltammograms obtained from the GOx/dendrimer multilayered electrodes revealed that bioelectrocatalytic response is directly correlated to the number of deposited bilayers. From the analysis of voltammetric and ellipsometric signals, the coverage of active enzyme per layer during the layering steps was estimated, demonstrating the spatially-ordered multilayer formation. As an extension of the study, dendrimers having various degrees of ferrocenyl modification were prepared and used. The resulting electrodes were electrochemically characterized, and the density of ferrocenyl groups, active enzyme coverage, and sensitivity were estimated. For the affinity-sensing surrface, a biosensor system based on avidin-biotin interaction was developed. As the building block of affinity monolayer, G4 dendrimer having partial ferrocenyl-tethered surface groups was prepared and used. And the biotinylated and electroactive dendritic monolayer was used for the affinity-sensing surface interacting with avidin. Electrochemical characterization of the resulting biosensor was conducted using free enzyme in electrolyte in terms of degree of surface coverage with avidin and subsequent surface shielding.

  • PDF

Surface Dose Measurement of Electron Beam within the Magnetic Field Variation (자기장 내에서 전자선의 표면선량 변화 측정)

  • Je, Jae-Yong;Noh, Kyung-Suk;Shin, Oon-Jae;Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This paper describes a electron field presence of magnetic field, intensity and shape surface dose variation to clinical application possibility. Materials and Methods: The using 6 MeV electron and $10{\times}10\;cm^2$ field size, 9 hole to shielding block make the by measure the film, when the magnetic field position inside and outside of the X-Omat film and parallel plate ionization chamber using the surface dose measured. Results: Present of 4 cm to the side at angle about 3 degree from beam center, use of ring type magnetic is 0.9% increase the surface dose, lens block located in the magnetic field the surface dose 1.58% increase, half magnetic field's position on the side of them at the field center of the 3.6% increase of the surface dose. Conclusion: Surface dose variation is with magnetic field about the mean electron beam of progress direction change, orbit region patient's is inconvenient without surface dose increase percentage case goodness will be used as a useful way.

  • PDF

Computed Tomographic Simulation of Craniospinal Irradiation (전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획)

  • Lee CI;Kim HN;Oh TY;Hwang DS;Park NS;Kye CS;Kim YS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

Design of single-chip NFC transceiver (단일 칩 NFC 트랜시버의 설계)

  • Cho, Jung-Hyun;Kim, Shi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.68-75
    • /
    • 2007
  • A single chip NFC transceiver supporting not only NFC active and passive mode but also 13.56MHz RFID reader and tag mode was designed and fabricated. The proposed NFC transceiver can operate as a RFID tag even without external power supply which has dual antenna structure for initiator and target. The area increment due to additional target antenna is negligible because the target antenna is constructed by using a shielding layer of initiator antenna. The analog front end circuit of the proposed NFC transceiver consists of a transmitter and receiver of reader/writer block supporting NFC initiator or RFID reader mode, and a tag circuit for target of passive NFC mode or RFID tag mode. The maximum baud rate of the proposed NFC device is 212kbps by using UART serial interface. The chip has been designed and fabricated using a Magnachip's $0.35{\mu}m$ double poly 4-metal CMOS process, and the effective area of the chip is 2200um by 3600um.

Development of an experimental model for radiation-induced inhibition of cranial bone regeneration

  • Jung, Hong-Moon;Lee, Jeong-Eun;Lee, Seoung-Jun;Lee, Jung-Tae;Kwon, Tae-Yub;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.34.1-34.8
    • /
    • 2018
  • Background: Radiation therapy is widely employed in the treatment of head and neck cancer. Adverse effects of therapeutic irradiation include delayed bone healing after dental extraction or impaired bone regeneration at the irradiated bony defect. Development of a reliable experimental model may be beneficial to study tissue regeneration in the irradiated field. The current study aimed to develop a relevant animal model of post-radiation cranial bone defect. Methods: A lead shielding block was designed for selective external irradiation of the mouse calvaria. Critical-size calvarial defect was created 2 weeks after the irradiation. The defect was filled with a collagen scaffold, with or without incorporation of bone morphogenetic protein 2 (BMP-2) (1 ㎍/ml). The non-irradiated mice treated with or without BMP-2-included scaffold served as control. Four weeks after the surgery, the specimens were harvested and the degree of bone formation was evaluated by histological and radiographical examinations. Results: BMP-2-treated scaffold yielded significant bone regeneration in the mice calvarial defects. However, a single fraction of external irradiation was observed to eliminate the bone regeneration capacity of the BMP-2-incorporated scaffold without influencing the survival of the animals. Conclusion: The current study established an efficient model for post-radiation cranial bone regeneration and can be applied for evaluating the robust bone formation system using various chemokines or agents in unfavorable, demanding radiation-related bone defect models.