• Title/Summary/Keyword: Shielding Design

Search Result 325, Processing Time 0.022 seconds

On the Particle Swarm Optimization of cask shielding design for a prototype Sodium-cooled Fast Reactor

  • Lim, Dong-Won;Lee, Cheol-Woo;Lim, Jae-Yong;Hartanto, Donny
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.284-292
    • /
    • 2019
  • For the continuous operation of a nuclear reactor, burnt fuel needs to be replaced with fresh fuel, where appropriate (ex-vessel) fuel handling is required. Particularly for the Sodium-cooled Fast Reactor (SFR) refueling, its process has unique challenges due to liquid sodium coolant. The ex-vessel spent fuel transportation should concern several design features such as the radiation shielding, decay-heat removal, and inert space separated from air. This paper proposes a new design optimization methodology of cask shielding to transport the spent fuel assembly in a prototype SFR for the first time. The Particle Swarm Optimization (PSO) algorithm had been applied to design trade-offs between shielding and cask weight. The cask is designed as a double-cylinder structure to block an inert sodium region from the air-cooling space. The PSO process yielded the optimum shielding thickness of 26 cm, considering the weight as well. To confirm the shielding performance, the radiation dose of spent fuel removed at its peak burnup and after 1-year cooling was calculated. Two different fuel positions located during transportation were also investigated to consider a functional disorder in a cask drive system. This study concludes the current cask design in normal operations is satisfactory in accordance with regulatory rules.

Analysis of radiation safety management status of medical linear accelerator facilities in Korea

  • Kwon, Na Hye;Shin, Dong Oh;Ann, So Hyun;Kim, Jin Sung;Choi, Sang Hyoun;Kim, Dong Wook
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.449-455
    • /
    • 2022
  • The rapid rise in the application of novel treatment techniques, such as intensity-modulated radiotherapy (IMRT), motivated us to survey the status of Korea's radiation safety management and the shielding designs of facilities employing medical linear accelerators (LINACs). To this end, a questionnaire was used to collect information on LINAC facilities and treatments, workload, shielding design, shielding management, and path of obtaining shielding information. Out of 100 domestic institutions, 52 responded to the survey. Approximately 70% of the institutions utilized IMRT for more than 60% of their cases, and an IMRT factor of 5 was adopted by 75% of these institutions. Over 80% of the institutions accounted for the applied time-averaged dose rate per week and instantaneous dose equivalent rates in their shielding designs. Approximately 45% of the institutions obtained important shielding information via a radiation shielding design company and the NCRP-151 report. Overall, most facilities were shown to follow the standards recommended by the relevant international agencies. However, the requirement to establish standardized shielding design information and clarify ambiguous paths for information acquisition was also highlighted. Therefore, the study's results can be used as a foundation for establishing a safety control system and for creating adequate shielding designs.

Prediction of Shielding Effectiveness in Honeycomb Structure Using the Modified Design Equation (수정된 설계 방정식을 이용한 허니컴 구조의 차폐 효과 예측)

  • Lee Kyung-Won;Cheong Yeong-Chul;Hong Ic-Pyo;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.862-871
    • /
    • 2005
  • In this paper, the modified design equation of shielding effectiveness was presented to predict more accurately the shielding effectiveness of honeycomb structure with hexagonal waveguide. The design equation of shielding effectiveness in honeycomb was represented from adding shielding effectiveness of single lattice to shielding effectiveness of infinite array of single lattice. This paper proposed the generalized design equation of shielding effectiveness by analyzing basis lattice of hexagonal waveguide which composes honeycomb structure and infinite array structure of basis lattice. To provide the validity of the modified design equation of shielding effectiveness in this paper, comparison with other available date using 3D EM commercial software is made.

Shielding 효과를 고려한 회로 설계 방법에 관한 연구

  • 김용규;권대한;황성우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.413-416
    • /
    • 2001
  • In high frequency range, RF circuit design without considering shielding effect can cause several significant changes due to increase in parasitic capacitance and inductance between RF signal lines and shielding box. In this paper, bandpass filter has been made to measure the shielding effect and its s-parameter has been measured by Vector Network Analyzer (VNA). Equivalent circuit model including the shielding effect has been constructed with the lumped elements extracted from the 3D electromagnetic simulator, Maxwell SI. Then, the validity of the model is verified using microwave circuit simulator, ADS (Advanced Design System).

  • PDF

Electromagnetic Wave Shielding Effectiveness of Electroless Chemical Copper and Nickel Plating PET fabrics (구리와 니켈 금속이 무전해 도금된 폴리에스테르 섬유의 구조에 따른 전자파 차폐성)

  • Chun, Tae-Il;Park, Jung-Hwan
    • Fashion & Textile Research Journal
    • /
    • v.10 no.3
    • /
    • pp.385-388
    • /
    • 2008
  • Four kinds of PET fabrics were coated with Copper and Nickel by electroless chemical plating, and the electromagnetic wave shielding effectiveness for those samples have been examined. The shielding effectiveness showed between 90 dB and 70 dB, and it related to the fabric structure, such as cover factor and cloth density. The dense fabric structure showed the better shielding effect.

Comparison of Striking Distance Formulae and Their Effect on Lightning Shielding Analysis (뇌 차폐 해석에서 뇌격흡인 거리 수식과 영향 비교)

  • Kim, Sung-Sam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.694-699
    • /
    • 2011
  • This paper compares the performance of lightning shielding analysis methods using the seven striking distance formulae in substation. For comparison, we evaluate the number of expected strikes and exposed area using WinIGS Software. Seven striking distance formulae are compared using the electrogeometric model analysis and the rolling sphere method. Based on the electrogeometric model analysis, the risk of shielding failure in either the whole substation or parts of it is determined. According to the simulation results, one can justify whether the substation satisfies the criterion of shielding design. In particular, according to the rolling sphere method, the exposed areas in substation determine the location of the additional shielding poles or shield wires. Therefore, the installation of the additional shielding poles and shield wires in substation was accepted by shield design at the phase conductors exposed in the larger area.

Scoping Calculations on Criticality and Shielding of the Improved KAERI Reference Disposal System for SNFs (KRS+)

  • Kim, In-Young;Cho, Dong-Keun;Lee, Jongyoul;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.37-50
    • /
    • 2020
  • In this paper, an overview of the scoping calculation results is provided with respect to criticality and radiation shielding of two KBS-3V type PWR SNF disposal systems and one NWMO-type CANDU SNF disposal system of the improved KAERI reference disposal system for SNFs (KRS+). The results confirmed that the calculated effective multiplication factors (keff) of each disposal system comply with the design criteria (< 0.95). Based on a sensitivity study, the bounding conditions for criticality assumed a flooded container, actinide-only fuel composition, and a decay time of tens of thousands of years. The necessity of mixed loading for some PWR SNFs with high enrichment and low discharge burnup was identified from the evaluated preliminary possible loading area. Furthermore, the absorbed dose rate in the bentonite region was confirmed to be considerably lower than the design criterion (< 1 Gy·hr-1). Entire PWR SNFs with various enrichment and discharge burnup can be deposited in the KRS+ system without any shielding issues. The container thickness applied to the current KRS+ design was clarified as sufficient considering the minimum thickness of the container to satisfy the shielding criterion. In conclusion, the current KRS+ design is suitable in terms of nuclear criticality and radiation shielding.

Synthesis of Application on the Product Design for the Shielding of the Electromagnetic wave in the Electrical Appliances (전자 기기의 유해 전자파 차폐를 위한 친환경 제품 디자인 활용도 분석)

  • Sung, Nak-Bong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.129-136
    • /
    • 2011
  • In this paper, the shielding material for the product design of various electrical appliances is suggested by more environmentally materials like as the lacquer and the charcoal. The suggested shielding material has the shielding effectiveness of 97.2%, 98.7%, and 96.3% at 900 MHz, 1.8 GHz, and 2.45 GHz, respectively. In the microwave oven and the cell phone, the metal or metal-coated plastic are used for the shielding of strong electromagnetic wave. However, by using more environmentally materials like as the lacquer and the charcoal, the products can be manufactured more light weighting, more heat-resisting, more abrasion resisting, and more corrosion resisting. Also, the products design can be varied more mellow and more friendly.

Process Design and Forming Analysis of Permalloy Shielding Can for Instrument Cluster (자동차 계기판용 퍼멀로이 실딩 캔의 성형해석 및 공정설계)

  • Kim, Dong-Hwan;Lee, Seon-Bong;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.177-185
    • /
    • 2001
  • This study shows the process design and forming analysis of permalloy shielding can that support the automobile multi-display parts to indicate the accurate information of car. This study is particularly important, since the strain and thickness of permalloy shielding can is known to affect the magnetic properties such as coercivity and permeability quite thickness of permalloy shielding can is known to affect the magnetic properties such as coercivity and permeability quite sensitively. The objective functions are strain and thickness deviation. The punch radius, die radius and blank holding force are considered as design parameters. Orthogonal array (OA) table and characteristics are applied to neural network (NN) as train data. After training, the optimal and robust condition of design parameters is selected. This study shows the correlation between the design methodology of NN and the statistical design of experiments (DOE) approach.

  • PDF

Survey of Radiation Shielding Design Goals and Workload Based on Radiation Safety Report: Tomotherapy Vault

  • Cho, Kwang Hwan;Jung, Jae Hong;Min, Chul Kee;Bae, Sun Hyun;Moon, Seong Kwon;Kim, Eun Seog;Cho, Sam Ju;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.42-46
    • /
    • 2018
  • The purpose of this study was to perform a survey of the radiation shielding design goals (P) and workload (W) based on the radiation safety reports concerned with structural shielding design for the IMRT treatment technique in Tomotherapy vaults. The values of the P and W factors as well as of a verified concrete thickness of the ceiling, bottom, sidewalls (sidewall-1 and sidewall-2), and door have been obtained from radiation safety reports for a total of 16 out of 20 vaults. The recommended and most widely used report for P values was the NCRP No. 151 report, which stated that the P factor in controlled and uncontrolled areas was 0.1 and 0.02 mSv/week, respectively. The range of the W factor was 600~14,720 Gy/week. The absorbed dose delivered per patient was 2~3 Gy. The maximum number of patients treated per day was 10~70. The quality assurance (QA) dose was 100~1,000 Gy/week. Fifteen values of the IMRT factor (F) were mostly used but a maximum of 20 values was also used. The concrete thickness for primary structures including the ceiling, bottom, sidewalls, and door was sufficient for radiation shielding. The P and W factors affect the calculation of the structural shielding design, and several parameters, such as the absorbed dose, patients, QA dose, days and F factor can be varied according to the type of shielding structure. To ensure the safety of the radiation shielding, it is necessary to use the NCRP No. 151 report for the standard recommendation values.