• 제목/요약/키워드: Shielding Analysis

검색결과 473건 처리시간 0.028초

유한요소법을 이용한 인공고관절 주대형태의 개선에 대한 연구 (A Study for Improvement of the Femoral Stem Type using the Finite Element Analysis)

  • 윤경렬;원예연;이수훈
    • 한국CDE학회논문집
    • /
    • 제5권2호
    • /
    • pp.122-126
    • /
    • 2000
  • A major mechanical problem with total hip replacement is the loosening of the femoral component. The loss of proximal support, with firm fixation distally, has been thought to be a major caused of fatigue failure of femoral stems. While many causes have been proposed, the most frequently suggested cause of the calcar resorption is the disuse atrophy of the cortex of the calcar due to the stress shielding of the proximal bone by the metal femoral stem. In this research, the new-designed stem(modified collar stem) was considered which made a hole inside stem and had a 3 mm thickness. Using the 3-dimensional finite element methods, the common collar stem and the modified colla stem was modeled and analysed. Also, the two models was compared. The results showed that the modified collar stem decreased the stress-shielding and it made a effective load transfer at the entire femoral region.

  • PDF

Study on Rod Position Indication System using Permanent Magnets with Shielding Plates for a Control Rod Drive Mechanism

  • Lee, Jae Seon;Cho, Sang Soon;Kim, Jong Wook
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.439-443
    • /
    • 2015
  • A control rod drive mechanism (CRDM) is an electromechanical equipment that provides linear movement for the control rods to control the nuclear reactivity in a nuclear reactor. A rod position indication system (RPIS) detects the control rod's position. To enhance the measurement accuracy of the system, a magnetostrictive type sensor with capability of generating operation limiting signals would be adapted instead of a conventional RPIS for a CRDM. An RPIS was modelled for a numerical analysis with the permanent magnets at the stationary limit positions and magnetic shielding plates with a moving permanent magnet. The performance analysis of the RPIS were conducted, and the results were discussed here.

극저주파 시스템에서 전자장 차폐효과 해석 및 개선 방안 (Analysis and Improvement of Shielding Effect of Electromagnetic Field in Extremely Low Frequency System)

  • 김상훈;최홍순;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.978-979
    • /
    • 2006
  • Recently, Peoples are exposed the ELF(Extremely Low Frequency) magnetic fields in the vicinity of underground transmission lines, and there are the generally accepted opinion that the magnetic fields affect the human body and there are possibility of the disease. Also in relation to this problem, technical solution methods and research are advanced for reducing the magnetic fields. In this paper, to practically understand the magnetic fields underground transmission lines, We analyze the electromagnetic field distribution in the underground transmission lines by means of FEM(Finite Element Methods) and present that improvement of the effective shielding methods by applying cable arrangements and shielding materials, eddy current problem to the underground transmission lines by means of the numerical analysis Tool.

  • PDF

풍력발전단지에 의한 레이다 차폐 현상 및 도플러 측정 데이터 분석 (Measurement and Analysis of Radar Shielding and Doppler Effects by the Wind Farm)

  • 김민;강기봉;박상홍;정주호
    • 한국전자파학회논문지
    • /
    • 제27권8호
    • /
    • pp.742-749
    • /
    • 2016
  • 현재 화석연료의 고갈 및 신재생 에너지의 필요성에 따라서 바람이 풍부한 해안지대에서 풍력발전단지가 건설되고 있다. 하지만 군사작전 지역 인근에 풍력발전단지가 건설되어질 경우, 풍력발전기의 레이다 차폐 현상 및 도플러 변조로 인하여 운용 중인 군사 레이다에 방해 현상을 초래할 수 있다. 이에 따라 실제 풍력발전기를 통한 전자기적 현상의 분석이 필요하다. 본 논문에서는 기존 문헌의 발전기 형태에 따른 이론적인 차폐거리 및 레이다 신호 모델링을 통하여 얻어진 도플러 주파수와 실제 운용되는 풍력발전기에서 측정된 전자기적 차폐거리 및 도플러 주파수의 비교를 수행하였다.

EN50289 동축케이블 전달 임피던스 측정 방법을 이용한 통신 케이블의 차폐 효과 분석 (Shielding Effect Analysis of Communication Cables Using EN50289 for Transfer Impedance Measurement of Coaxial Cable)

  • 이근봉;장난;전지운;송승제;나완수
    • 한국전자파학회논문지
    • /
    • 제25권11호
    • /
    • pp.1156-1163
    • /
    • 2014
  • 본 논문에서는 EN50289 규격에 따른 동축케이블의 전달 임피던스 측정을 이용하여 여러 가지 통신 케이블의 차폐 특성을 분석하였다. EN50289 규격에서의 전달 임피던스 측정 방법은 CENELEC(European Committee For Electrotechnical Standardization)에서 규정한 Triaxial 방법이며, IEC Standard 96-1에서 규정한 Triaxial 방법과 달리 측정하고자 하는 동축케이블과 외부 도체의 직경에 관계없이 동축케이블의 전달 임피던스를 측정할 수 있는 장점이 있다. 본 논문에서는 EN50289 규격에 따른 동축케이블의 전달 임피던스 측정장치를 설계/제작하였으며, 이것을 이용한 실험 결과를 통해 측정 시스템의 신뢰할만한 주파수 대역을 결정하였고, 동축케이블의 쉴딩 기법의 차이에서 오는 영향에 대하여 분석하였다. 전달 임피던스 측정 결과, 케이블의 쉴딩 기법에 따라 전달 임피던스의 상당한 차이가 있음을 보였다. 또한, RG-58 통신용 케이블의 전달 임피던스 이론식에 의한 계산값과 측정값의 비교를 통하여 측정된 데이터가 유효함을 보였다.

The influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material

  • Mohammad W. Marashdeh;Fawzy H. Sallam;Ahmed M. Abd El-Aziz;Mohamed I. Elkhatib;Sitah f. Alanazi;Mamduh J. Aljaafreh;Mohannad Al-Hmoud;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2740-2747
    • /
    • 2024
  • The sintering process acquired ferromagnetic copper ferrite ceramic material with a small concentration of Ni ion at 1100 ℃ for 1 h. Previously, copper ferrite with Ni proportions powder was acquired by the wet chemical process according to the relation CuFe2-xNixO4 where x takes values 0.0, 0.015, 0.03, 0.04, and 0.05. The role of Ni ion in the copper ferrite structure was investigated by X-ray analysis, Scanning electron microscope, EDX analysis, and density measurements. The gamma-ray shielding properties for the fabricated CuFeNiO ceramics samples were evaluated using the Monte Carlo simulation method. The obtained results show an enhancement in the linear attenuation coefficient for the fabricated ceramics with increasing the insertions of Ni ions within the fabricated samples, where increasing the Ni ions concentration between 0 and 1.19 wt% increases the linear attenuation by between 1.581 and 1.771 cm-1 (at 0.103 MeV), 0.304-0.338 cm-1 (at 0.662 MeV), and 0.160-0.178 cm-1 (at 2.506 MeV), respectively. Simultaneously, the radiation protection efficiency for a 1 cm thickness of the fabricated samples increased between 14.8 and 16.3% with increasing the Ni ions between 0 and 1.19 wt%. Although the Ni doping concentration does not exceed 1.5 wt% of the total composition of the fabricated ceramics, the shielding capacity of the fabricated ceramics was enhanced by more than 11%, along the studied energy interval. Therefore, the fabricated samples can be used in gamma-ray shielding applications.

PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구 (Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility)

  • 김태만;서명환;조천형;차길용;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.92-100
    • /
    • 2015
  • 경수로 사용후핵연료 건식 중간저장시설의 방사선영향평가 효율성 개선을 목적으로 '선원항 지정방법에 따른 민감도 평가', '2-Step 계산'기법 개발 및 '냉각기간 이득효과' 적용에 따른 방사선 영향평가를 수행하였다. 본 연구에서는 저장건물의 용기배열 순서에 따라 순차적으로 선원항을 지정하여 직접선량에 미치는 민감도를 평가하였으며, 차폐건물 외벽에서의 방사선량은 내벽과 인접한 최근접 2개 열에 의한 영향이 지배적임을 확인하였다. 또한, 저장시설에 차폐 건물이 도입될 경우, 막대한 전산해석 시간을 감소시키기 위해 '2-Step 계산'기법을 수립하여 평가한 결과는 절반가량의 해석시간으로 직접(1-Step) 계산결과와 유사한 결과를 도출하였다. 마지막으로, 저장시설에 순차적으로 저장되는 저장용기의 보관기간을 사용후핵연료의 실제 냉각기간을 적용하면 건물 외벽에서의 방사선량이 냉각기간을 모두 동일하게 설정한 계산값에 비해 40% 정도 낮게 평가됨을 확인하였다. 본 연구는 중간저장시설의 방사선 영향평가를 위한 몬테칼로 차폐해석 방법의 효율성을 향상시키고자 수행되었으며, 좀 더 다양한 사례에 대한 평가를 통하여 신뢰성을 향상시킨다면 저장시설의 설계 및 부지경계 기준설정에 활용할 수 있을 것이다.

Gamma Radiation Shielding Effect of Various Heavy Concretes Using Domestic Mineral Aggregates

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.149-161
    • /
    • 1970
  • 국내에서 산출되는 광물골재를 사용하여 방사선 차폐용 중차폐 콘크리트를 제조하고 감마선에 대한 차폐효능을 규명하는 동시에 방사선 차폐체로서의 활용가능성을 검토하였다. 10여종의 각기 다른 광물골재를 수집하여 방사선 차폐용 골재로서의 사용타당성을 검토하기 위한 물리시험과 화학분석이 실시되었고 이 결과를 토대로 최적한 골재를 선택하여 중차폐 콘크리트가 제조되었다. 차폐용 콘크리트를 제조하는데 골재의 배합비, 물-세멘트 비율, 세골재, 조골재 비율 등을 달리해주므로써 방사선 차폐효과가 달라지는 현상을 실험적으로 구해 보았고 그 결과 차폐체의 비중이 높고 균질성이 좋은 중차폐체의 설계 조건을 유도해 낼수 있었다. 각기 다른 중차폐체에 대한 차폐효능 실험은 60Co 감마선원을 사용한 방사선 투과시험법으로 구했다. 실험을 통하여 중차폐체에 대한 방사선 차폐능과 차폐콘크리트의 비중, 차폐가격등을 분석하므로써 차폐설계상 최적의 공간배치로서 가장 경제적으로 차폐치를 설계할 수 있는 최적의 조건을 얻을 수 있었다.

  • PDF

나노분말이 분산된 에폭시 섬유수지의 전자파차폐 효과 (Electromagnetic Wave Shielding Effect of Nano-powder Dispersed Epoxy Resin Composite)

  • 한준영;이철희;최민규;홍순직;박중학;이동진
    • 한국분말재료학회지
    • /
    • 제22권4호
    • /
    • pp.234-239
    • /
    • 2015
  • Electronic products are a major part of evolving industry and human life style; however most of them are known to emit electromagnetic waves that have severe health hazards. Therefore, different materials and fabrication techniques are understudy to control or limit transfer of such waves to human body. In this study, nanocomposite powder is dispersed into epoxy resin and shielding effects such as absorption, reflection, penetration and multiple reflections are investigated. In addition, nano size powder (Ni, $Fe_2O_3$, Fe-85Ni, C-Ni) is fabricated by pulsed wire evaporation method and dispersed manually into epoxy. Characterization techniques such as X-ray diffraction, Scanning electron microscopy and Transmission electron microscopy are used to investigate the phase analysis, size and shape as well as dispersion trend of a nano powder on epoxy matrix. Shielding effect is measured by standard test method to investigate the electromagnetic shielding effectiveness of planar materials, ASTM D4935. At lower frequency, sample consisting nano-powder of Fe-85%Wt Ni shows better electromagnetic shielding effect compared to only epoxy, only Ni, $Fe_2O_3$ and C-Ni samples.

전도성 금속 피복재의 전기전도도에 의한 전자파 차폐효과 분석 (Analysis of Electromagnetic Wave Shielding Effectiveness from Electrical Conductivity of Metallized Conductive Sheets)

  • 김영식;최익권;김성수
    • 한국재료학회지
    • /
    • 제9권9호
    • /
    • pp.913-918
    • /
    • 1999
  • 전자파 차폐특성 측정방법의 일환으로 매질의 전기전도도로부터 차폐효과를 정성적 수준에서 예측하는 연구를 수행하였다. 사용된 시편은 전도성 금속 (Cu, Ni)이 피복된 망사형 차폐재로 두께는 0.1 mm 정도이고, 전기전도도는 6.4$\times$10~2.4$\times$10(sup)5 mhos/m 범위 값을 가졌다. 물질상수와 시편의 두께로 표시되는 반사손실 및 흡수손실의 이론식을 도출하고 상기 시편에 대해 차폐효과를 계산하였다. 전도성 피복재의 경우 주된 차폐기구는 반사손실임을 밝힐 수 있었으며, 전기전도도가 증가함에 따라 차폐효과는 현저히 증가함을 알 수 있었다. 이들 이론치를 임피던스 실측치로부터 계산된 반사손실과 비교한 결과 10 dB 이내의 오차를 보임으로써 제안한 분석방법의 타당성을 입증하였다.

  • PDF