Abstract
For the purpose of improving the efficiency of the radiation impact assessment of dry interim storage facilities for the spent nuclear fuel of pressurized water reactors (PWRs), radiation impact assessment was performed after the application of sensitivity assessment according to the radiation source term designation method, development of a 2-step calculation technique, and cooling time credit. The present study successively designated radiation source terms in accordance with the cask arrangement order in the shielding building, assessed sensitivity, which affects direct dose, and confirmed that the radiation dosage of the external walls of the shielding building was dominantly affected by the two columns closest to the internal walls. In addition, in the case in which shielding buildings were introduced into storage facilities, the present study established and assessed the 2-step calculation technique, which can reduce the immense computational analysis time. Consequently, results similar to those from existing calculations were derived in approximately half the analysis time. Finally, when radiation source terms were established by adding the storage period of the storage casks successively stored in the storage facilities and the cooling period of the spent nuclear fuel, the radiation dose of the external walls of the buildings was confirmed to be approximately 40% lower than the calculated values; the cooling period was established as being identical. The present study was conducted to improve the efficiency of the Monte Carlo shielding analysis method for radiation impact assessment of interim storage facilities. If reliability is improved through the assessment of more diverse cases, the results of the present study can be used for the design of storage facilities and the establishment of site boundary standards.
경수로 사용후핵연료 건식 중간저장시설의 방사선영향평가 효율성 개선을 목적으로 '선원항 지정방법에 따른 민감도 평가', '2-Step 계산'기법 개발 및 '냉각기간 이득효과' 적용에 따른 방사선 영향평가를 수행하였다. 본 연구에서는 저장건물의 용기배열 순서에 따라 순차적으로 선원항을 지정하여 직접선량에 미치는 민감도를 평가하였으며, 차폐건물 외벽에서의 방사선량은 내벽과 인접한 최근접 2개 열에 의한 영향이 지배적임을 확인하였다. 또한, 저장시설에 차폐 건물이 도입될 경우, 막대한 전산해석 시간을 감소시키기 위해 '2-Step 계산'기법을 수립하여 평가한 결과는 절반가량의 해석시간으로 직접(1-Step) 계산결과와 유사한 결과를 도출하였다. 마지막으로, 저장시설에 순차적으로 저장되는 저장용기의 보관기간을 사용후핵연료의 실제 냉각기간을 적용하면 건물 외벽에서의 방사선량이 냉각기간을 모두 동일하게 설정한 계산값에 비해 40% 정도 낮게 평가됨을 확인하였다. 본 연구는 중간저장시설의 방사선 영향평가를 위한 몬테칼로 차폐해석 방법의 효율성을 향상시키고자 수행되었으며, 좀 더 다양한 사례에 대한 평가를 통하여 신뢰성을 향상시킨다면 저장시설의 설계 및 부지경계 기준설정에 활용할 수 있을 것이다.