• 제목/요약/키워드: Sheet splitting

검색결과 10건 처리시간 0.024초

고강도 열연 강판 적용 단판형 로어암 (1-Piece Typed Lower Control Arm Using High Strength Hot Rolled Steel Sheet)

  • 김대용;오승택;윤치상;한도석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.228-229
    • /
    • 2007
  • As one way of weight saving of the vehicle, 1-piece typed lower control arm has been developed using high strength hot rolled steel sheet. In order to overcome the edge splitting problem during edge flanging or burring process, HER (hole expansion ratio) value of steel sheet was primarily considered. The strength grade of steel sheet and the shape were optimized utilizing Taguchi method.

  • PDF

CFRP Sheet로 보강한 콘크리트의 저속 충격하중에 하에서의 펀칭파괴 거동 (Punching Behavior of Concrete Strengthening with CFRP Sheet under Low Velocity Impact Loading)

  • 민경환;조성훈;안미영;이진영;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.9-10
    • /
    • 2010
  • 본 연구에서는 CFRP로 보강한 2방향 콘크리트의 정하중 및 저속 충격하중에 대한 실험을 수행하였다. 압축강도 40MPa의 콘크리트 및 이와 동일한 배합에 0.75%의 강섬유를 혼입한 강섬유 보강 콘크리트로 $50{\times}350{\tims}350mm$의 부재를 제작하여 CFRP로 보강하였다. CFRP와 강섬유로 보강한 시험체는 콘크리트가 쪼개지는 파괴와 펀칭 파괴가 복합적으로 나타나고, 이 때 쪼갬 균열 수는 보강하지 않은 콘크리트에 비해 확연하게 줄어들었다. CFRP와 강섬유로 동시에 보강한 시편은 충격하중 하에서 2방향 콘크리트 시험체가 파괴되는 데에 6.8배의 에너지가 소모되었다.

  • PDF

Experimental and theoretical research on the compression performance of CFRP sheet confined GFRP short pole

  • Chen, Li;Zhao, Qilin;Jiang, Kebin
    • Structural Engineering and Mechanics
    • /
    • 제40권2호
    • /
    • pp.215-231
    • /
    • 2011
  • The axial compressive strength of unidirectional FRP is generally quite lower than its axial tensile strength. This fact decreases the advantages of FRP as main load bearing member in engineering structure. In order to restrain the lateral expansion and splitting of GFRP, and accordingly heighten its axial compressive bearing capacity, a project that to confine GFRP pole with surrounding CFRP sheet is suggested in the present study. The Experiment on the CFRP sheet confined GFRP poles showed that a combined structure of high bearing capacity was attained. Basing on the experiment research a theoretical iterative calculation approach is suggested to predict the ultimate axial compressive stress of the combined structure, and the predicted results agree well with the experimental results. Then the influences of geometrical parameters on the ultimate axial compressive stress of the combined structure are also analyzed basing on this approach.

Bearing Strength of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.652-660
    • /
    • 2015
  • To study the bearing characteristics of glass fiber reinforced glulam for structural design, bearing strength tests were performed. Bearing loads were applied in the direction parallel to the grains, and the holes were prepared in such a way that the bolts would bear and support all the layers. The yield bearing strengths of the glass fiber reinforced glulam were found to be similar to those of the non-reinforced glulam, and were almost constant regardless of increases in bolt diameter. The ratio of the experimental yield bearing strength to the estimated bearing strength according to the suggested equation of the Korea Building Code and National Design Specification was 0.91~1.03. For the non-reinforced glulam and the sheet glass fiber reinforced plastic glulam, the maximum bearing load was measured according to the splitting fracture of specimens under bolt. The textile glass fiber reinforced glulam underwent only an embedding failure caused by the bearing load. The failure mode of reinforced glulam according to bearing load will influence the failure behavior of bolted connection, and estimating the shear yield strength of the bolted connection of the reinforced glulam is necessary, not only by using the bearing strength characteristics but also using the fracture toughness of the reinforced glulam.

전색보호판과 다단발파기를 이용한 다단식분산발파의 현장 적용 사례 (Case study on the Distributed Multi-stage Blasting using Stemming-Help Plastic Sheet and Programmable Sequential Blasting Machine)

  • 김세원;임익환;김재성
    • 화약ㆍ발파
    • /
    • 제31권2호
    • /
    • pp.14-24
    • /
    • 2013
  • 도심지에서 암반 제거 작업에 시공되어 온 방법 중 가장 효과적인 방법은 소량의 화약류를 사용하여 장약 전색한 후 발파하여 암반에 균열을 발생시켜 암석을 제거하는 방법인데, 환경적인 요인으로 인하여 그 사용에 제한을 받는 경우가 많아지고 발파 불가 지역이 늘어나고 있는 실정이다. 이 공법은 암반에 천공된 공속에 장약을 할 때 전색보호판을 이용하고 같은 시차의 뇌관과 화약으로 다단 장약/전색하고 다단발파기를 이용하여 최적화 된 정밀제어를 함으로써 진동을 감소시켜 발파하는 다단식분산발파 방법으로 모든 현장에 사용 가능하지만 특히 진동과 관련된 분쟁이 큰 도심 지역의 암반 제거에 있어서 더 효과적으로 사용할 수 있다. 이 공법은 일반적으로 천공되어지는 짧은 천공장(1.2~3.0미터)으로 인해 다단 장약 후 지연 기폭이 힘든 구간에서도 뇌관선이 단락 되거나 폭발화약 주변의 화약이 사압을 받는 일이 없이 쉽게 발파패턴을 설계하여 사용 할 수 있다.

텅스텐산화물/금속기판의 광전극 특성 (Photoelectrochamical characteristics of $WO_3$ on metal substrate for hydrogen production)

  • 고근호;;서선희;이동윤;이원재
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.99.2-99.2
    • /
    • 2011
  • Transparent conducting oxides (TCOs) supported on glass are widely used as substrates in PEC studies for photovoltaic hydrogen generation applications However, high sheet resistane ($10{\sim}15{\Omega}/cm^2$) and fragileness of glass-supported TCO substrates are the obstacles to produce the large area PEC cells. Such internal sheet resistance is detrimental to efficient collection of photogenerated majority charge carriers at the photoactive material and electrolyte interface. Moreover, these TCO substrates are very expensive and consume about 40~60% cost of the devices. Hence, a low sheet resistance of the substrate is a key point in improving the performance of PEC devices. Metallic substrates coated with a photoactive material would be a good choice for efficient charge collection. Such metal substrates based photanodes are best candidate for large-scale phtoelectrochemical water splitting for hydrogen generation. In this study, we report the enhanced PEC performance of $WO_3$ film on metal(chemical etched, bare) substrate. It is proposed that interface between $WO_3$ and the metal substrate is responsible for efficient charge transfer and demonstrated significant improvement in the photoelectrochmical performance. X-ray diffration and FESEM suduies reveled that $WO_3$ films are monoclinic, porous, polycrystalline with average grain size of ~50nm. Photocurrent of $WO_3$ prepared on metal substrates was measured in 0.5M $H_2SO_4$ electroyte under simulated $100mW/cm^2$ illumination.

  • PDF

Synthesis of $TiO_2$ nantubes coupled with ${\alpha}-Fe_2O_3$ nanoparticles and investigation of their photoelectrochemical activity

  • Mao, Aiming;Park, Jong-Hyeok;Han, Gui-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.99-102
    • /
    • 2009
  • $TiO_2$ nanotube arraysdecorated with ${\alpha}-Fe_2O_3$ were prepared by forming a nanotube-like $TiO_2$ film on a Ti sheet using an anodization process, followed by electrochemical deposition treatment to decorate hematite (${\alpha}-Fe_2O_3$) nanoparticles on the $TiO_2$ nanotube arrays. The SEM and XRD results revealed that the ${\alpha}-Fe_2O_3$ nanoparticles were homogeneously embedded on the surface of the $TiO_2$ nanotube arrays. The activity of hydrogen production by photocatalytic water decomposition for the ${\alpha}-Fe_2O_3/TiO_2$ nanotube array composite was examined under visible light irradiation.

  • PDF

Shear Performance of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.661-671
    • /
    • 2015
  • To evaluate the shear performance of the textile glass fiber and the sheet glass fiber reinforced glulam bolted connections, a tension type shear test was conducted. The average yield shear strength of the bolted connection of reinforced glulam was increased by 12% ~ 31% compared to the non-reinforced glulam. It was confirmed that the shear performance of 5D end distance of the glass fiber reinforced glulam connection corresponds to that of 7D of the non-reinforced glulam connection proposed in building design requirements in various countries. Compared to the non-reinforced glulam, the average shear strength of textile glass fiber reinforced glulam was markedly increased. The non-reinforced glulam and the GFRP reinforced glulam underwent a momentary splitting fracture. However, the failure mode of textile glass fiber reinforced glulam showed a good ductility.

Power Failure Sensitivity Analysis via Grouped L1/2 Sparsity Constrained Logistic Regression

  • Li, Baoshu;Zhou, Xin;Dong, Ping
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권8호
    • /
    • pp.3086-3101
    • /
    • 2021
  • To supply precise marketing and differentiated service for the electric power service department, it is very important to predict the customers with high sensitivity of electric power failure. To solve this problem, we propose a novel grouped 𝑙1/2 sparsity constrained logistic regression method for sensitivity assessment of electric power failure. Different from the 𝑙1 norm and k-support norm, the proposed grouped 𝑙1/2 sparsity constrained logistic regression method simultaneously imposes the inter-class information and tighter approximation to the nonconvex 𝑙0 sparsity to exploit multiple correlated attributions for prediction. Firstly, the attributes or factors for predicting the customer sensitivity of power failure are selected from customer sheets, such as customer information, electric consuming information, electrical bill, 95598 work sheet, power failure events, etc. Secondly, all these samples with attributes are clustered into several categories, and samples in the same category are assumed to be sharing similar properties. Then, 𝑙1/2 norm constrained logistic regression model is built to predict the customer's sensitivity of power failure. Alternating direction of multipliers (ADMM) algorithm is finally employed to solve the problem by splitting it into several sub-problems effectively. Experimental results on power electrical dataset with about one million customer data from a province validate that the proposed method has a good prediction accuracy.