검색결과 254건 처리시간 0.024초

전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석 (An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors)

  • 강동화;강동화;신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

앵글을 전단연결재로 사용하는 합성보의 휨성능 (Flexural Capacity of the Composite Beam using Angle as a Shear Connector)

  • 김영주;배재훈;안태상;최종권
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.63-75
    • /
    • 2015
  • 본 연구에서는 앵글을 전단연결재로 사용하여 합성보의 휨성능을 실험적으로 조사하였다. 실험의 주요변수는 앵글의 크기와 간격 및 콘크리트가 합성 전과 합성 후의 휨에 대한 전체적인 거동을 실험적으로 검증하였다. 또한 중공PC슬래브와 일반RC슬래브와 같이 사용하였을 때의 휨성능을 비교하였다. 이를 종합적으로 판단하면, 앵글을 전단연결재로 사용한 합성보의 휨성능은 앵글의 간격을 적절하게 배치시키면 예상내력보다 25-55% 이상의 공칭내력을 보유하고 있음을 확인할 수 있었다. 예상한 바와 같이, 합성보의 내력에 미치는 앵글의 변수를 살펴보면 앵글의 크기가 클수록 앵글의 간격이 좁을수록 합성보의 내력이 상승함을 확인할 수 있었다. 또한 중공PC슬래브에서도 앵글을 사용한 합성보의 성능이 잘 발휘됨을 실험적으로 검증하였다.

파형 GFRP 전단연결재의 폭 및 너비에 따른 중단열 벽체의 면내전단거동 (Effects of Corrugated GFRP Shear Connector Width and Pitch on In-plane Shear Behavior of Insulated Concrete Sandwich Wall Panels (CSWP))

  • 장석준;오태식;유영찬;김호룡;윤현도
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.421-428
    • /
    • 2014
  • 이 연구는 파형 GFRP 전단연결재가 보강된 중단열 벽체의 면내전단거동을 알아보기 위하여 실시되었다. 기존의 중단열 벽체의 단열성능 향상과 내/외측 벽체의 합성거동을 위하여 파형 GFRP 전단연결재를 보강하였다. 실험체는 2개의 단열재로 구분된 3개의 콘크리트 벽체로 구성되어 있으며, 중앙부 벽체에 수직방향의 전단력을 가하였다. 주요변수는 단열재의 종류 (압출법 보온판 및 비드법 보온판) 및 보강된 전단연결재의 너비(300 및 400 mm)과 폭(10 및 15 mm)를 변수로 설정하였으며, 실험체의 파괴양상 및 전단흐름강도-평균상대변위 관계 대한 분석을 실시하였다. 실험 결과 콘크리트와 단열재의 부착응력은 중단열 벽체의 초기거동에 상당한 영향이 있는 것으로 판단되며, 전단연결재가 보강되지 않은 경우 XPSS를 사용한 중단열 벽체의 강성 및 강성이 EPS 단열재의 경우보다 높게 나타났다. 전단연결재의 보강효과는 단열재에 따라 상이하게 나타났으며, 전단연결재의 보강상세에 단열재의 역학적 특성을 고려해야 할 것으로 판단된다.

Numerical analysis of tilted angle shear connectors in steel-concrete composite systems

  • Khorramian, Koosha;Maleki, Shervin;Shariati, Mahdi;Jalali, Abdolrahim;Tahir, M.M.
    • Steel and Composite Structures
    • /
    • 제23권1호
    • /
    • pp.67-85
    • /
    • 2017
  • This study investigates numerically the behavior of tilted angle shear connectors embedded in solid concrete slabs. Two different tilted angle connectors were used, titled angle with 112.5 and 135 degrees between the angle leg and steel beam flange. A nonlinear finite element model was developed to simulate and validate the experimental push-out tests. Parametric studies were performed to investigate the variations in concrete strength and connector's dimensions. The results indicate that the ultimate strength of a tilted angle shear connector is directly related to the square root of the concrete compressive strength. The effects of variations in the geometry of tilted angle connectors on the shear capacity are discussed in details. Based on the numerical analyses, two equations are proposed to estimate the ultimate capacity of tilted angle shear connectors of 112.5 and 135 degrees in the defined range of parameters.

초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가 (Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete)

  • 강재윤;정우태
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.5015-5020
    • /
    • 2015
  • 기존에 제안된 Perfobond rib connector의 강도평가식은 압축강도가 약 50 MPa 이하의 콘크리트 강도 범위에 대한 Push-out test의 결과로 유도된 것으로서, 압축강도 80 MPa 이상의 초고성능 콘크리트에 대한 전단 연결재 성능 평가를 위하여 Perfobond rib 연결재의 전단강도를 파악하기 위한 Push-out test를 수행하였다. Perfobond rib connector의 제작변수는 관통홀의 지름 및 개수이며, 강섬유가 혼입된 180 MPa의 콘크리와 강섬유를 혼입하지 않은 압축강도 80 MPa의 콘크리트를 적용하여 콘크리트 강도 변화에 대한 전단강도 변화를 검토하였다. 실험결과, 콘크리트 강도와 홀의 개수가 증가함 따라 전단강도가 증가하며, 다웰 효과에 의한 전단강도 증가율도 큰 것으로 나타났다. 기존에 다른 연구자들이 제안한 강도식으로 계산된 예측치와 비교한 결과, 실험값은 Oguejiofor & Hosain[2]이 제안한 강도식에 근접한 결과를 보였다.

Bolted connectors with mechanical coupler embedded in concrete: Shear resistance under static load

  • Milicevic, Ivan;Milosavljevic, Branko;Pavlovic, Marko;Spremic, Milan
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.321-337
    • /
    • 2020
  • Contemporary design and construction of steel-concrete composite structures employs the use of prefabricated concrete elements and demountable shear connectors in order to reduce the construction time and costs and enable dismantling of elements for their potential reuse at the end of life of buildings. Bolted shear connector with mechanical coupler is presented in this paper. The connector is assembled from mechanical coupler and rebar anchor, embedded in concrete, and steel bolt, used for connecting steel to concrete members. The behaviour and ultimate resistance of bolted connector with mechanical coupler in wide and narrow members were analysed based on push-out tests and FE analyses conducted in Abaqus software, with focus on concrete edge breakout and bolt shear failure modes. The effect of concrete strength, concrete edge distance and diameter and strength of bolts on failure modes and shear resistance was analysed. It was demonstrated that premature failure by breakout of concrete edge occurs when connectors are located 100 mm or closer from the edge in low-strength and normal-strength reinforced concrete. Furthermore, the paper presents a relatively simple model for hand calculation of concrete edge breakout resistance when bolted connectors with mechanical coupler are used. The model is based on the modification of prediction model used for cast-in and post-installed anchors loaded parallel to the edge, by implementing equivalent influence length of connector with variable diameter. Good agreement with test and FE results was obtained, thus confirming the validity of the proposed method.

Behavior of steel and concrete composite beams with a newly puzzle shape of crestbond rib shear connector: an experimental study

  • Le, Van Phuoc Nhan;Bui, Duc Vinh;Chu, Thi Hai Vinh;Kim, In-Tae;Ahn, Jin-Hee;Dao, Duy Kien
    • Structural Engineering and Mechanics
    • /
    • 제60권6호
    • /
    • pp.1001-1019
    • /
    • 2016
  • The connector is the most important part of a composite beam and promotes a composite action between a steel beam and concrete slab. This paper presents the experiment results for three large-scale beams with a newly puzzle shape of crestbond. The behavior of this connector in a composite beam was investigated, and the results were correlated with those obtained from push-out-test specimens. Four-point-bending load testing was carried out on steel-concrete composite beam models to consider the effects of the concrete strength, number of transverse rebars in the crestbond, and width of the concrete slab. Then, the deflection, ultimate load, and strains of the concrete, steel beam, and crestbond; the relative slip between the steel beam and the concrete slab at the end of the beams; and the failure mechanism were observed. The results showed that the general behavior of a steel-concrete composite beam using the newly puzzle shape of crestbond shear connectors was similar to that of a steel-concrete composite beam using conventional shear connectors. These newly puzzle shape of crestbond shear connectors can be used as shear connectors, and should be considered for application in composite bridges, which have a large number of steel beams.

합성 지하벽의 전단내력 산정에 관한 실험적 연구 (Experimental Study on the Shear Capacity of Composite Basement Walls)

  • 김성만;이성호;서수연;이리형;홍원기;장재호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.379-384
    • /
    • 2001
  • This paper presents the experimental result of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector. Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, arrangement of shear connector, thickness of wall, shear span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

  • PDF

Numerical analysis of large stud shear connector embedded in HFRC

  • He, Yu Liang;Zhang, Chong;Wang, Li Chao;Yang, Ying;Xiang, Yi Qiang
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.595-608
    • /
    • 2021
  • To investigate the mechanical behavior of large stud shear connector embedded in hybrid fiber-reinforced concrete (HFRC), a refined 3D nonlinear finite element (FE) model incorporating the constitutive model of HFRC was developed using ANSYS. Firstly, the test results conducted by the authors (He et al. 2017) were used to validate FE model of push out tests. Secondly, a total of 27 specimens were analyzed with various parameters including fiber volume fractions of HFRC, diameter of studs and HFRC strength. Finally, an empirical equation considering the contribution of steel fiber (SF) and polypropylene fiber (PF) was recommended to estimate the ultimate capacity of large stud shear connector embedded in HFRC.

Experimental and numerical study of large high strength bolt shear connector embedded in HFRC

  • Yuliang He;Zhengxin Wang;Weiming Wu;Ying Yang;Yiqiang Xiang
    • Steel and Composite Structures
    • /
    • 제49권2호
    • /
    • pp.197-213
    • /
    • 2023
  • To investigate the static properties of large high strength bolt shear connector in hybrid fiber-reinforced concrete (HFRC) and normal concrete (NC), eight push-out test specimens with single/double nut and HFRC/NC slabs were designed and push-out tests were conducted. A fine 3D nonlinear finite element (FE) model including HFRC constitutive model was established by using ANSYS 18.0, and the test results were used to verify FE models of the push-out test specimens. Then a total of 13 FE models were analyzed with various parameters including fiber volume fractions of HFRC, bolt diameter and thickness of steel flange. Finally, the empirical equations considering the contribution of polypropylene fiber (PF) and steel fiber (SF) obtained from the regression of the test results and FE analysis were recommended to evaluate the load-slip curve and ultimate capacity of the large high strength bolt shear connector embedded in HFRC/NC.