• Title/Summary/Keyword: Shear span to depth ratio

Search Result 224, Processing Time 0.025 seconds

A Study of Shear Resistance Characteristics using Shear Test Data with Stirrup (전단보강철근이 있는 기존 전단실험 자료를 이용한 전단특성에 관한 연구)

  • Shin Geun Ok;Lee Chang Shin;Jeong Jae Pyong;Kim Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.403-406
    • /
    • 2005
  • This paper deals with the propriety of the shear test data with stirrup reported in ACI and ASCE structural journal and the shear resistance characteristics affected by compressive strength of concrere($f_{ck}$), shear span-to-depth ratio (a/d), tensile reinforcement ratio($\rho$), and shear reinforcement ratio($rho_{v}$). The analysis was accomplished by the 242 shear test data. The test data include the flexural failure data around 40$\%$.

  • PDF

Shear behavior of concrete-encased square concrete-filled steel tube members: Experiments and strength prediction

  • Yang, Yong;Chen, Xin;Xue, Yicong;Yu, Yunlong;Zhang, Chaorui
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.431-445
    • /
    • 2021
  • This paper presents experiments and theoretical analysis on shear behavior of eight concrete-encased square concrete-filled steel tube (CECFST) specimens and three traditional reinforced concrete (RC) specimens. A total of 11 specimens with the test parameters including the shear span-to-depth ratio, steel tube size and studs arrangement were tested to explore the shear performance of CECFST specimens. The failure mode, shear capacity and displacement ductility were thoroughly evaluated. The test results indicated that all the test specimens failed in shear, and the CECFST specimens enhanced by the interior CFST core exhibited higher shear capacity and better ductility performance than that of the RC specimens. When the other parameters were the same, the larger steel tube size, the smaller shear span-to-depth ratio and the existence of studs could lead to the more satisfactory shear behavior. Then, based on the compatible truss-arch model, a set of formulas were developed to analytically predict the shear strength of the CECFST members by considering the compatibility of deformation between the truss part, arch part and the steel tube. Compared with the calculated results based on several current design specifications, the proposed formulas could get more accurate prediction.

Predicting shear strength of SFRC slender beams without stirrups using an ANN model

  • Keskin, Riza S.O.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.5
    • /
    • pp.605-615
    • /
    • 2017
  • Shear failure of reinforced concrete (RC) beams is a major concern for structural engineers. It has been shown through various studies that the shear strength and ductility of RC beams can be improved by adding steel fibers to the concrete. An accurate model predicting the shear strength of steel fiber reinforced concrete (SFRC) beams will help SFRC to become widely used. An artificial neural network (ANN) model consisting of an input layer, a hidden layer of six neurons and an output layer was developed to predict the shear strength of SFRC slender beams without stirrups, where the input parameters are concrete compressive strength, tensile reinforcement ratio, shear span-to-depth ratio, effective depth, volume fraction of fibers, aspect ratio of fibers and fiber bond factor, and the output is an estimate of shear strength. It is shown that the model is superior to fourteen equations proposed by various researchers in predicting the shear strength of SFRC beams considered in this study and it is verified through a parametric study that the model has a good generalization capability.

Energy absorption of reinforced concrete deep beams strengthened with CFRP sheet

  • Panjehpour, Mohammad;Abang Ali, Abang Abdullah;Aznieta, Farah Nora
    • Steel and Composite Structures
    • /
    • v.16 no.5
    • /
    • pp.481-489
    • /
    • 2014
  • The function of carbon fibre reinforced polymer (CFRP) reinforcement in increasing the ductility of reinforced concrete (RC) deep beam is important in such shear-sensitive RC member. This paper aims to investigate the effect of CFRP-strengthening on the energy absorption of RC deep beams. Six ordinary RC deep beams and six CFRP-strengthened RC deep beams with shear span to the effective depth ratio of 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00 were tested till failure in this research. An empirical relationship was established to obtain the energy absorption of CFRP-strengthened RC deep beams. The shear span to the effective depth ratio and growth of energy absorption of CFRP-strengthened deep beam were the significant factors to establish this relationship.

Experimental Study for GFRP Reinforced Concrete Beams without Stirrups (스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2014
  • This paper evaluates the shear strength, behavior and failure mode of reinforced concrete beams with deformed GFRP reinforcing bar. Four concrete beam specimens were constructed and tested. It was carried out to observe failure behavior and load-deflection of simply supported concrete beams subjected to four-point monotonic loading. In order to eliminate of the uncertainty by the shear reinforcements, any stirrups were not used. Variables of the specimens were shear span-depth ratio, effective reinforcement ratio. The dimensions of specimen is 3,300 or $1,950mm{\times}200mm{\times}240mm$. Clear span and shear span were 2,900mm, 1,000mm respectively. Shear span-depth ratios were 6.5 and 2.5. Effective ratios of Longitudinal GFRP reinforcing bar were $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$ and $0.634{\rho}_{fb}$. All beam specimens were broken by diagonal-tension shear and the ACI 440.1R, CSA S806 and ISIS, which was used to design test beams, showed considerable deviation between prediction and test results of shear strengths.

Shear strength of reinforced concrete dapped-end beams

  • Lin, Ing-Jaung;Hwang, Shyh-Jiann;Lu, Wen-Yao;Tsai, Jiunn-Tyng
    • Structural Engineering and Mechanics
    • /
    • v.16 no.3
    • /
    • pp.275-294
    • /
    • 2003
  • In this study, 24 high-strength concrete dapped-end beams were tested to study the effects of the amount of main dapped-end reinforcement, the nominal shear span-to-depth ratio, and the concrete strength on the shear strength of dapped-end beams. Test results indicate that the shear strength of dapped ends increases with the increase in the amount of main dapped-end reinforcement and the concrete strength. The shear strength of dapped-end beam increases with the decrease of nominal shear span-to-depth ratio. A simplified method for determining the shear strength of reinforced concrete dapped ends is also proposed in this paper. The shear strengths predicted by the proposed method and the approach of PCI Design Handbook are compared with test results. The comparison shows that the proposed method can more accurately predict the shear strength of reinforced concrete dapped-end beams than the approach of PCI Design Handbook.

A Prediction of Shear Strength Using Arch Models in Reinforced Concrete Beams without Web Reinforcement (아치모델을 이용한 복부보강이 안된 철근 콘크리트 보의 전단강도 산정)

  • 김대중
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.233-240
    • /
    • 1998
  • A rational expression, developed to predict the shear strength of reinforced concrete beams, is derived from the relationship between shear and the rate of change of bending moment along a beam coupled with experimental findings for the arch action. The proposed ultimate shear strength equation, arising from analytical premises and then calibrated with experimental data, is a similar form to the ACI 318 equation derived mainly from empirical approach. The proposed equation depends on the concrete compressive strength, amount of longitudinal steel content, and the shear span-to-depth ratio, and rationally reflects the shear resistance mechanism of combined beam action and arch action in reinforced concrete beams. The proposed equation applied to existing test data and the results were compared with those predicted by the ACI 318 equation and the Zsutty's equation.

A Study on Shear Capacity of High Strength Lightweight Reinforced Concrete T-Beams (고강도 경량콘크리트를 사용한 철근콘크리트 T 형보의 전단성능)

  • 김진수;김원호;박성무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.220-225
    • /
    • 1993
  • This paper is an experimental study on shear capacity of the high strength lightweight reinforced concrete beams with shear-depth ratio between 1.5 and 2.5. Thirteen T & rectangular beams were tested to determine their diagonal cracking and ultimate shear capacity. The major variables are shear span-depth ratio (a/d=1.5, 2.0, 2.5), concrete compressive strength(f'c=210, 24., 270㎏/㎠) and tensile steel ratio( =0.6, 1.2%). Based on results obtained from experiment of high strength lightweight reinforced concrete Beam & normal concrete, the following conclusions were drawn. (1) The shear capacity of high-strength lightweight concrete is less 15% than that of normal concrete under same condition. (2) As the results of Comparing this experimental datas with other various formulas. It is regarded that ACI 318-89 shear strength formula related tensile strength is proper to design formula of shear strength of high-strength lightweight reinforced concrete using lightweight concrete.

  • PDF

Plastic hinge length of circular reinforced concrete columns

  • Ou, Yu-Chen;Kurniawan, Raditya Andy;Kurniawan, Dimas Pramudya;Nguyen, Nguyen Dang
    • Computers and Concrete
    • /
    • v.10 no.6
    • /
    • pp.663-681
    • /
    • 2012
  • This paper presents a parametric study of the plastic hinge length of circular reinforced concrete columns using a three-dimensional finite element analysis method, and using the Taguchi robust design method to reduce computational cost. Parameters examined include the longitudinal reinforcing ratio, the shear span-to-depth ratio, the axial force ratio and the concrete compressive strength. The study considers longitudinal reinforcement with yield strengths of 414 MPa and 685 MPa, and proposes simplified formulas for the plastic hinge length of circular reinforced concrete columns, showing that increases in plastic hinge length correlate to increases in the axial load, longitudinal reinforcing and shear span-to-depth ratios. As concrete strength increases, the plastic hinge length decreases for the 414 MPa case but increases for the 685 MPa case.

New Approach for Shear Capacity Prediction of High Strength Concrete Beams without Stirrups (스터럽이 없는 고강도 콘크리트 보의 전단강도 예측을 위한 새로운 예측식의 제안)

  • Choi, Jeong-Seon;Lee, Chang-Hoon;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.611-620
    • /
    • 2006
  • In the shear failure mechanism of a beam, beam and arch actions always exist simultaneously. According to the shear span to depth ratio, the proportion between these two actions is varied and the contribution of these actions to shear capacity is changed. Moreover, the current codes provide recommendations based on experimental results of normal strength concrete, so the application range of concrete strength must be extended. Based on this mechanism and new requirement, a simplified analytical equation for shear capacity prediction of reinforced high strength concrete beams without stirrups is proposed. To reflect the change in the contribution between these actions, stress variation in the longitudinal reinforcement along the span is considered by use of the Jenq and Shah Model. Dowel action with horizontal splitting failure and shear friction between cracks are also taken into account. ize effect is included to derive a more precise equation. Regression analysis is performed to determine each variable and simplify the equation. And, the formula derived from theoretical approaches is evaluated by comparison with numerous experimental data, which are in broad range of concrete strength(especially in high strength concrete), shear span to depth ratio, geometrical size and longitudinal steel ratio. It is shown that the proposed equation is more accurate and simpler than other empirical equations, so a wide range of a/d can be considered in one equation.