• Title/Summary/Keyword: Shear Strength Ratio

Search Result 1,130, Processing Time 0.027 seconds

Using Recycled Aggregates in Sustainable Resource Circulation System Concrete for Environment Preservation (녹색자연환경 보존을 위한 지속가능한 자원순환시스템 콘크리트)

  • Lee, Young-Joo;Jang, Jung-Kwun;Kim, Yoon-Il;Lim, Chil-Soon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.57-61
    • /
    • 2010
  • In this study, many concrete specimens were tested to investigate the variations of strength characteristics of high-strength concrete due to amount of recycled coarse aggregates, and to investigate the effect of steel-fiber reinforcement on concrete using recycled coarse aggregates. Test results showed that all of the variations of compressive, tensile and flexural strength appeared in linear reduction according to icrease the amount of recycled coarse aggregates, and steel-fiber reinforcement of 0.75% volumn of concrete recovered completely spliting tensile strength and flexual strength and recovered greatly compressive strength of concrete using recycled coarse aggregates of 100% displacement. And test results showed that the shear strength falled rapidly at 30% of replacement ratio so far as 34% of strength reduction ratio, but after that it falled a little within 3% up to the replacement ratio 100%, and steel-fiber reinforcement of 0.75% of concrete volumn recovered completely the deteriorated shear strength, moreover improved the shear strength above 50% rather than that of concrete using natural coarse aggregates.

  • PDF

Shear mechanism of steel fiber reinforced concrete deep coupling beams

  • Li, Kou;Zhao, Jun;Ren, Wenbo
    • Structural Engineering and Mechanics
    • /
    • v.73 no.2
    • /
    • pp.143-152
    • /
    • 2020
  • Deep coupling beams are more prone to suffer brittle shear failure. The addition of steel fibers to seismic members such as coupling beams can improve their shear performance and ductility. Based on the test results of steel fiber reinforced concrete(SFRC) coupling beams with span-to-depth ratio between 1.5 and 2.5 under lateral reverse cyclic load, the shear mechanism were analyzed by using strut-and-tie model theory, and the effects of the span-to-depth ratio, compressive strength and volume fraction of steel fiber on shear strengths were also discussed. A simplified calculation method to predict the shear capacity of SFRC deep coupling beams was proposed. The results show that the shear force is mainly transmitted by a strut-and-tie mechanism composed of three types of inclined concrete struts, vertical reinforcement ties and nodes. The influence of span-to-depth ratio on shear capacity is mainly due to the change of inclination angle of main inclined struts. The increasing of concrete compressive strength or volume fraction of steel fiber can improve the shear capacity of SFRC deep coupling beams mainly by enhancing the bearing capacity of compressive struts or tensile strength of the vertical tie. The proposed calculation method is verified using experimental data, and comparative results show that the prediction values agree well with the test ones.

Shear strength model for reinforced concrete corbels based on panel response

  • Massone, Leonardo M.;Alvarez, Julio E.
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.723-740
    • /
    • 2016
  • Reinforced concrete corbels are generally used to transfer loads within a structural system, such as buildings, bridges, and facilities in general. They commonly present low aspect ratio, requiring an accurate model for shear strength prediction in order to promote flexural behavior. The model described here, originally developed for walls, was adapted for corbels. The model is based on a reinforced concrete panel, described by constitutive laws for concrete and steel and applied in a fixed direction. Equilibrium in the orthogonal direction to the shearing force allows for the estimation of the shear stress versus strain response. The original model yielded conservative results with important scatter, thus various modifications were implemented in order to improve strength predictions: 1) recalibration of the strut (crack) direction, capturing the absence of transverse reinforcement and axial load in most corbels, 2) inclusion of main (boundary) reinforcement in the equilibrium equation, capturing its participation in the mechanism, and 3) decrease in aspect ratio by considering the width of the loading plate in the formulation. To analyze the behavior of the theoretical model, a database of 109 specimens available in the literature was collected. The model yielded an average model-to-test shear strength ratio of 0.98 and a coefficient of variation of 0.16, showing also that most test variables are well captured with the model, and providing better results than the original model. The model strength prediction is compared with other models in the literature, resulting in one of the most accurate estimates.

Effect of particle size on direct shear deformation of soil

  • Gu, Renguo;Fang, Yingguang;Jiang, Quan;Li, Bo;Feng, Deluan
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.135-143
    • /
    • 2022
  • Soils are natural granular materials whose mechanical properties differ according to the size and composition of the particles, so soils exhibit an obvious scale effect. Traditional soil mechanics is based on continuum mechanics, which can not reflect the impact of particle size on soil mechanics. On that basis, a matrix-reinforcing-particle cell model is established in which the reinforcing particles are larger-diameter sand particles and the matrix comprises smaller-diameter bentonite particles. Since these two types of particles deform differently under shear stress, a new shear-strength theory under direct shear that considers the stress concentration and bypass phenomena of the matrix is established. In order to verify the rationality of this theory, a series of direct shear tests with different reinforcing particle diameter and volume fraction ratio are carried out. Theoretical analysis and experimental results showed that the interaction among particles of differing size and composition is the basic reason for the size effect of soils. Furthermore, the stress concentration and bypass phenomena of the matrix enhance the shear strength of a soil, and the volume ratio of reinforcing particles has an obvious impact on the shear strength. In addition, the newly proposed shear-strength theory agrees well with experimental values.

Shear Behavior of High-Strength Concrete Deep Beams and Comparisons with ACI Shear Design Provisions (고강도 철근콘크리트 깊은 보의 전단거동 및 ACI 전단설계 기준과의 비교)

  • 정헌수;양근혁;함영삼
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.874-882
    • /
    • 2002
  • Currently, deep beams are designed according to ACT 318-99 equations derived from experimental data for slender beams with normal-strength concrete. In addition, there is relatively limited information on high-strength concrete deep beams with shear reinforcement. The purpose of this experimental study is to investigate the shear behavior of high-strength concrete deep beams and to grasp the conservatism of ACI shear design provisions. Experimental results on the shear behavior of 22 deep beams under two equal symmetrically placed point loads are reported. compressive strength of concrete cylinder was 800kgf/$\textrm{cm}^2$, and main variables were vertical and horizontal shear reinforcement and shear span-to-overall depth ratio (а/h). Test results showed that for high-strength concrete deep beams with shear span-to-overall depth ratio exceeding 0.75, the vertical shear reinforcement more effectively resisted the shear load than horizontal shear reinforcement. In high-strength concrete deep beams, ACI shear design provisions tended to underestimate the effect of strut-tie action and vertical shear reinforcement and overestimate the ones of horizontal shear reinforcement. Based on the experimental results of high-strength concrete deep beams and shear friction theory, this study modified the equations on the shear capacity specified by the ACI provisions.

Shear Strenhth and Ductility of Steel-Fiber Reinforced High Strength Concrete Beams with Shear Confinement (전단보강이 있는 강섬유 보강 고강도 철근콘크리트 보의 전단 및 연상에 관한 연구)

  • 오정근;이광수;권영호;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.4
    • /
    • pp.53-60
    • /
    • 1990
  • Investigations on the behavior of steel fiber reinforced high strength concrete beams with shear confinement are accomplished to determine their ultimate shear strength including diagonal tension strength. The parameters varied were the shear confinement ratio(Ps), and fiber volume fraction(Vs). Ultimate shear strength increased significantly in steel fiber reinforced concrete beam without shear confinement. In steel- fiber reinforced high strength concrete beams with shear confinement, there is no increase of ultimate shear strength but shows much beneficial effects of Ductility Capacity.

Shear and impact strength of waste plastic fibre reinforced concrete

  • Karanth, Savithri S;Ghorpade, Vaishali G;Rao, H Sudarsana
    • Advances in concrete construction
    • /
    • v.5 no.2
    • /
    • pp.173-182
    • /
    • 2017
  • This paper is aimed at determining the shear and impact strength of waste plastic fibre reinforced concrete. M30 grade of concrete is prepared with waste plastic door fibres cut into 5 mm width and aspect ratios of 30, 50, 70, 90 and 110. Fibres are used in a volume fraction of 0 to 1.5% with an increment of 0.25%. L shaped specimens are cast for shear strength tests and flat plates of size $250{\times}250{\times}30mm$ are used for impact tests. "Drop ball method" is used for checking the impact strength. Shear strength is checked with L shaped specimens under UTM with a special attachment. It was found that up to 1.25% of waste plastic fibres can be effectively used for better strength of concrete both in shear and impact. Shear and impact strength were found to be increasing up to a volume fraction of fibres of 1.25%.

A Study on the Shear Behavior of Reinforced High Strength Lightweight Concrete Beams (경량고강도 콘크리트보의 전단거동에 관한 연구)

  • 신종률;권우현;권기혁;곽윤근;노희일
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.4
    • /
    • pp.149-159
    • /
    • 1996
  • Recent advances in material technology has accelerated the development of higher strength concretes using lightweight manufactured aggregates.Concretes with these chnractcristics are designable since the reductiun of dead loads and the increase in load capacity can oflix substantial cost reductions. Alt,hough thesc rharackristics are very desirable, very little information is availablc to the structural rivic;~~,cher about the properties of highstrength lightweight concrete. In general, shear strength of reinforced concrete beams is dependent on the compressive strength of concrete. the longitudinal steel ratio, the shear span to the depth ratio and shear reinforcement. In this study. eight single reinforced high strength lightweight concrete beams were tested to investigate their behavior and to determine their ultimate shear strengths.The variables studied in this investigation are shear span to effective depth ratio a/d = 1.5. 2.5, 3.5 and 4.5 : vertical shear reinforcement ratio ${\rho}_8= 0%$ and 1.136%. Test results were analyzed and compared with strengths predicted by ACI code equation. Zsutty's equation. As the results, ACI Eq.(ll-3) and ACI Eq.(ll-6) are conservative for high strength lightweight concrete beam. Also Zsuttyrs Eq. is conservative for beams except short beams. (a/d= 1.5)

Influence of Column Aspect Ratio on the Punching Shear Strength of Flat Plate Slab-Column Edge Connections (플랫 플레이트 슬래브-외부기둥 접합부의 뚫림전단강도에 대한 기둥 형상비의 영향)

  • Shin, Sung-Woo;Choi, Myung-Shin;Kim, Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.121-129
    • /
    • 2007
  • The aim of this study is to investigate punching shear strength of exterior connections in the flat plate structure with rectangular column. To inspect the effect of column aspect ratios on the punching shear behavior, eight specimens for exterior connection were made and tested. In this experimental program the length of critical perimeter was kept constant, while column aspect ratio varied from 2.0 to 4.5. Two levels of concrete strength and slab reinforcement ratio were also considered. As the column aspect ratio increased, the punching shear strengths are decreased. The decrement of punching shear strength was small in specimens with high aspect ratio of column.

Evaluation and Improvement of Deformation Capacities of Shear Walls Using Displacement-Based Seismic Design

  • Oh, Young-Hun;Han, Sang-Whan;Choi, Yeoh-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.55-61
    • /
    • 2006
  • RC shear walls are frequently used as lateral force-resisting system in building construction because they have sufficient stiffness and strength against damage and collapse. If RC shear walls are properly designed and proportioned, these walls can also behave as ductile flexural members like cantilevered beams. To achieve this goal, the designer should provide adequate strength and deformation capacity of shear walls corresponding to the anticipated deformation level. In this study, the level of demands for deformation of shear walls was investigated using a displacement-based design approach. Also, deformation capacities of shear walls are evaluated through laboratory tests of shear walls with specific transverse confinement widely used in Korea. Four full-scale wall specimens with different wall boundary details and cross-sections were constructed for the experiment. The displacement-based design approach could be used to determine the deformation demands and capacities depending on the aspect ratio, ratio of wall area to floor plan area, flexural reinforcement ratio, and axial load ratio. Also, the specific boundary detailing for shear wall can be applied to enhance the deformation capacity of the shear wall.