• Title/Summary/Keyword: Shape Defect

Search Result 419, Processing Time 0.026 seconds

Polyurethane Semi-occlusive Dressing for Full Thickness Skin Graft Application (전층식피술에 적용한 폴리우레탄 반밀봉드레싱)

  • Lee, Hyuk Gu;Son, Dae Gu;Kim, Hyun Ji;Kim, Jun Hyung;Han, Ki Hwan
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.607-612
    • /
    • 2005
  • A traditional tie-over dressing may be applied to support the take of a skin graft. Although there are many advantage of this method, it has significant disadvantages, including time-consuming application. Furthermore, when the dressing is changed, the gauze becomes hard and can be stuck to the graft, causing damage and pain upon removal. The purpose of our study is to evaluate the effect of semi-occlusive dressing using polyurethane foam and film dressing($Allevyn^{(R)}$, $Opsite^{(R)}$) after full thickness skin graft. The authors treated 45 cases including burn scar contracture(n=38), syndactyly (n=1), absence of nipple-areolar complex(n=4), traumatic skin defect(n=1) and contact burn(n=1) with authors' method and 39 patients including burn scar contracture (n=39) with the tie-over dressing between 2000 and 2004. The patients in polyurethane foam and film dressing group ranged from 1 to 62 years of age (mean age, 15.1 years) and the patients in tie-over dressing group ranged from 2 to 60 years of age(mean age, 21.3 years). The postoperative results were analyzed according to the following measures: (1) the duration of graft-taking, (2) the admission period, (3) complications. Compared with the traditional tie-over dressing, polyurethane foam and film dressing was shown to be more successful in a reduced duration of graft-taking, in which was similar to the former in the rate of graft-taking, a reduced admission period and patient's discomfort. We concluded that semi-occlusive dressing using $Allevyn^{(R)}$ and $Opsite^{(R)}$ was an effective method after full thickness skin graft, which was easy to shape to difficult body locations, such as web spaces, fingers and maintains a moist environment for wound healing and does not stick to the wound.

A Study on Improvement of Extrudability for Extrusion Process of Heat Sink (방열판 직접압출공정의 성형성 향상에 관한 연구)

  • 이정민;김병민;강충길
    • Transactions of Materials Processing
    • /
    • v.13 no.5
    • /
    • pp.422-428
    • /
    • 2004
  • At present, the design of extrusion dies and operation in extrusion companies are primarily based on trial and error. The experience of the die designer, the press operator and the die corrector determine the performance of the extrusion die and the efficiency of the process. In order to produce defect-free products of desirable quality in terms of strength, surface quality and geometrical dimensions, it is important to obtain more knowledge of the processes that occur during extrusion. Recently, to reduce the costs of designing and manufacturing of extrusion dies, and to ensure the quality of the extruded products, numerical simulation for extrusion processes such as FEM (finite element method) is applied increasingly and becomes a very important tool for the design and development of new products. However, most of the studies about FE simulation have been accomplished for simple geometry and low extrusion ratio in the filed of steady metal flow conditions. The extruded products of AI alloy in industrial practice involve complicated sectional geometry. This study was designed to reduce the time of die design and manufacturing in the extrusion process using FEM simulation. FEM simulations of extrusion process were performed in non-steady states conditions by changing weld plate included in extrusion die set. Product which was employed in this study is heat sink that has been used in the parts of heat exchanger of electric circuits. It is generally applied for aluminum or its alloys due to heat efficiency and easy production of complicated shapes, and manufactured by extrusion process. The simulated results showed that weld plate shape in extrusion dies influences meta] flow and dimensional accuracy of products.

Free Vascularized Fibular Transfer with Double Barrel Fashion (혈관부착 생비골 중첩 이식술)

  • Chung, Duke-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.54-61
    • /
    • 1998
  • Free vascularized fibular is the most usuful bony donor of the long bone reconstruction in reconstructive microsurgical field. It has many benifits such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter with long pedicle, minimal donor site morbity too. In that situations of the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transfered. The bony circulation of the fibula has two ways, one from nutrient artery via peroneal artery through nutrient foramen which makes endosteal arterial network inside of the fibula, another way is periosteal network through outside encircling vascular network of the bone which distributed in muscle sleeves of the fibular diaphysis. Authors modified free vascularized fibular bone graft with transverse osteotomy is made from the anterolateral aspect of the fibular shaft just distal to entry of the nutrient artery. This produces two vascularized bone struts that may be folded pararell to each other but that remain connected by the periosteum and muscle cuff surrounding the peroneal artery and veins. The proximal strut is vascularized by both a periosteal and endosteal blood supply, whereas the distal strut is vascularized by a periosteal blood supply alone. This procedure can call "doule barrel" free vascularized fibular graft. We performed 7 cases of doule barrel fashined fibular transplantation on distal femur and proximal tibial large defects. Average bone union time takes 7 months from that procedure. There were no significant bone union time differences between both proximal and distal struts. After solid union of the transfered double barrel fibular graft, there were no stress fracture in our series. We can propose double barrel free vascualized fibular graft is usuful method in that cases with very large bone defect on large long bones especially metaphyseal defects.

  • PDF

A Study on the Signal Correction for Multiple Defects in MFL Type Nondestructive Testing System (MFL 비파괴 검사 시스템에서 다중 결함에 의한 신호 왜곡과 신호 보정에 관한 연구)

  • Park, Jeng Hoon;Kim, Hui Min;Park, Gwan Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.24-30
    • /
    • 2016
  • MFL (Magnetic flux leakage) type nondestructive testing has been used for inspection of underground gas pipelines to find metal defects by detecting magnetic leakage signal. Because the underground gas pipeline is exposed by environment such as high pressure with great humidity, external defects are easily formed on the surface of pipelines and they are being grouped respectively. These adjacent defects cause the signal distortion of leakage flux so that it is hard to estimate the shape information of defects. In this paper, we performed to study of the signal distortion and compensating method for multiple defects in MFL type nondestructive testing system by using 3D FEM simulation. This paper proposes the basic algorithm of defect signal analysis on multiple defects on the surface of 30 inch diameter pipeline.

Formation Behavior of Anodic Oxide Films on Al 6061 Alloy in Sulfuric Acid Solution (황산 용액에서 Al6061 합금의 아노다이징 피막 형성거동)

  • Moon, Sungmo;Jeong, Kihun;Lim, Sugun
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.6
    • /
    • pp.393-399
    • /
    • 2018
  • Formation behavior of aluminum anodic oxide (AAO) films on Al6061 alloy was studied in view of thickness, morphology and defects in the anodic films in 20 vol.% sulfuric acid solution at a constant current density of $40mA/cm^2$, using voltage-time curve, observation of anodized specimen colors and surface and cross-sectional morphologies of anodic films with anodization time. With increasing anodizing time, voltage for film formation increased exponentially after about 12 min and its increasing rate decreased after 25 min, followed by a rapid decrease of the voltage after about 28 min. Surface color of anodized specimen became darker with increasing anodizing time up to about 20 min, while it appeared to be brighter with increasing anodizing time after 20 min. The darkened and brightened surfaces with anodizing time are attributed to an increase in thickness of porous anodic oxide film and a chemical damage of the films due to heat generated by increased resistance of the film, respectively. Cross-sectional observation of AAO films revealed the formation of defects of crack shape at the metal/oxide interface after 15 min which prevents the growth of AAO films. Width and length of the crack-like defect increased with anodizing time up to 25 min of anodizing, and finally the outer part of AAO films was partly dissolved or detached after 30 min of anodizing, resulting in non-uniform surface structures of the AAO films.

Reconstruction of cutaneous defects of the nasal tip and alar by two different methods

  • Kim, Yong Hun;Yoon, Hyung Woo;Chung, Seum;Chung, Yoon Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.260-263
    • /
    • 2018
  • Background: The alar and nasal tip are important subunits of the nose. Determining the optimal procedure for reconstructing a cutaneous defect in a nasal subunit depends on several factors including size, location, and involvement of deep underlying structures. We treated cutaneous defects after tumor ablation in the alar and nasal tip with a local flap, using an S-shaped design and a modified V-Y advancement flap with a croissant shape. Methods: We analyzed 36 patients with skin tumors who underwent flap coverage after tumor ablation. Rotation flaps were used in 26 cases and croissant-shaped V-Y advancement flaps were used in 10 cases. The primary cause of the defects was skin cancer, except for one benign tumor. Results: The mean patient age was 71 years. The size of the defects ranged from $0.49cm^2$ to $3.5cm^2$. No recurrence of skin cancer was noted and all flaps lasted until the end of follow-up. Partial desquamation of the epidermis was noted in one case. The postoperative appearance for most patients was excellent, objectively and subjectively. Conclusion: For cutaneous defects of up to about $4.0cm^2$ of the alar and nasal tip, local flaps using our methods offered a good cosmetic and therapeutic result. The main advantage of our flaps is the minimal dissection required compared to bilobed and other local flap methods. We believe our flaps are a suitable option for alar and nasal tip reconstruction.

Quality Evaluations of Induction Motor Rotors during Die Casting Process II (유도전동기 회전자 금형주조 시 품질평가 II)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.347-352
    • /
    • 2019
  • This study focused on improving the cast quality of small-sized induction motor rotors during the die casting process. A new rotor core cast model was proposed based on previous research results and parametric studies. Numerical analyses using 3-dimensional half models were performed to evaluate the filling patterns of aluminum molten metals into a mold and on-site experiment performed to verify the newly proposed cast model. The following were obtained from numerical filling analyses and experimental results. First, molten metals started to fill the lower end ring, then moved on to fill the core slot and upper end ring and finally stopped to fill at the rotor core slot. Second, significant circulation of molten metals was not observed on the lower end ring, resulting in fewer defects at the section of the lower end ring from the experimental results. Third, the new shape of a rotor core cast was effective in producing rotors with sound cast quality, and reducing the end ring cast defect area by approximately 70 %.

Factors Influencing Characteristics of Sand Core for Water Jacket in Automotive Cylinder Blocks Casting (자동차 실린더 블록 주조에서 워터 자켓용 샌드 코어 특성에 영향을 미치는 인자)

  • Kim, Ki-Jun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.2
    • /
    • pp.185-191
    • /
    • 2021
  • The characteristics of the foundry sand were analyzed for water jacket core required to prevent structural deformation from the heat generated in the cylinder bore during the casting of the cylinder block of an automobile. The sand core tensile strength tester, AFS-GFN, and optical microscope were used to evaluate the its properties. If the SiO2 content is high in the foundry sand, the dimensional defects and veining defects occur due to high temperature expansion. Also, if it is too low, the core breakage, porosities, chemical burn-on defects occur. The particle size index and grain shape influenced the core strength and resin consumption, resulting in fluctuations in defect types. The higher the alkalinity of the dried sand, the lower the core strength. And the more basic, the lower the core strength. At the resin content of 1.6~1.8%, the increase in core strength after 1 hour curing was approximately at its maximum.

A Study on Effect of Pad Design on Assembly and Adhesion Reliability of Surface Mount Technology (SMT) (표면실장기술(SMT)의 조립 및 접합 신뢰성에 대한 패드설계의 영향에 관한 연구)

  • Park, Dong-Woon;Yu, Myeong-Hyeon;Kim, Hak-sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.3
    • /
    • pp.31-35
    • /
    • 2022
  • Recently, with the 4th industrial revolution, the demand for high-density semiconductors for large-capacity data processing is increasing. Researchers are interested in researching the reliability of surface mount technology (SMT). In this study, the effect of PCB pad design on assembly and adhesion reliability of passive component was analyzed using design of experiment (DOE). The DOE method was established using the pad length, width, and distance between pads of the PCB as variables. The assembly defect rate of the passive element after the reflow process was derived according to the misplacement direction of the chip resistor. The shear force between the passive element and the PCB was measured using shear tests. In addition, the shape of the solder according to the pad design was analyzed through cross-sectional analysis.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.