• Title/Summary/Keyword: Shape Alignment

Search Result 167, Processing Time 0.031 seconds

An Experimental Study on Local Scour around Abutment (교대주변의 국부세굴에 관한 실험적 연구)

  • An, Sang-Jin;Hwang, Bo-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.3
    • /
    • pp.255-263
    • /
    • 1999
  • The laboratory datas are for local scour depth measurement at vertical-wall abutment. These include the data to demonstrate the effects of local scour depth of abutment nose shape, alignment angle, flow depth and flume slope. The pattern of local scour were measured and analyzed the abutments which are rectangular, sharp, chamfered rectangular and ablong nose shapes. The experiments were carried out with varing the flume slope and alignment algle increasing flow depth every step in 1cm for four abutment types on the live-bed scour conditions. The flume slope and alignment angle were varied in five cases : for latter 30 $^{\circ}$, 60 $^{\circ}$, 90 $^{\circ}$, 120 $^{\circ}$ and 150 $^{\circ}$, for former 0.01%, 0.03%, 0.05%, 0.1% and 0.2%. The maximum scour depths were analyzed for the shaped of abutment nose with rectangular, ablong, chamfered rectangular and sharp in order. The results of the experiments show that the scour depth varies not only with abutment nose shapes and alignment angle but also with the flow depth and flume slope.

  • PDF

Research of Optimum Reflow Process Condition for 0402 Electric Parts (0402칩의 무연솔더링 최적공정 연구)

  • Bang, Jung-Hwan;Lee, Se-Hyung;Shin, Yue-Seon;Kim, Jeong-Han;Lee, Chang-Woo
    • Journal of Welding and Joining
    • /
    • v.27 no.1
    • /
    • pp.85-89
    • /
    • 2009
  • Reflow process conditions were investigated for 0402 electric parts with Sn-3.0Ag-0.5Cu solders. Circle hole shape metal mask with 100 m thickness showed excellent printability. Self alignment abilities were 71% for 1005 chips, 52% for 0603 chips, and 3% for 0402 chips. Average joining strengos were 1990 gf for 1005 chips, 867 gf for 0603 chips, and 525 gf for 0402 chips. As mis-mounting angle increased, joining strength decreased. Considering self-alignment ability, mounting angle had to be under $5^{\circ}$ and contact area of the chips had to be over 40% for Pb-free soldering process for 0402 chips.

Development of a Vision-based Blank Alignment Unit for Press Automation Process (프레스 자동화 공정을 위한 비전 기반 블랭크 정렬 장치 개발)

  • Oh, Jong-Kyu;Kim, Daesik;Kim, Soo-Jong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2015
  • A vision-based blank alignment unit for a press automation line is introduced in this paper. A press is a machine tool that changes the shape of a blank by applying pressure and is widely used in industries requiring mass production. In traditional press automation lines, a mechanical centering unit, which consists of guides and ball bearings, is employed to align a blank before a robot inserts it into the press. However it can only align limited sized and shaped of blanks. Moreover it cannot be applied to a process where more than two blanks are simultaneously inserted. To overcome these problems, we developed a press centering unit by means of vision sensors for press automation lines. The specification of the vision system is determined by considering information of the blank and the required accuracy. A vision application S/W with pattern recognition, camera calibration and monitoring functions is designed to successfully detect multiple blanks. Through real experiments with an industrial robot, we validated that the proposed system was able to align various sizes and shapes of blanks, and successfully detect more than two blanks which were simultaneously inserted.

Acute Bone Remodeling after Reduction of Nasal Bone Fracture on Computed Tomography Imaging

  • Lee, Bong Moo;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.63-69
    • /
    • 2014
  • Background: A number of studies have reported complication after reduction of nasal bone fractures. Among complicated cases, some showed improvement in shape of the nose with passage of time. Therefore, we examined these changes using computed tomography (CT) images taken over intervals. Methods: CT scans of 50 patients with new nasal bone fractures were reviewed, and the images were compared amongst preoperative, immediately postoperative, and one month scans. Changes in nasal bone shape, were evaluated based on the angle of nasal bone arch between the nasal bone and frontal process of maxilla, overall shape of arch, mal-alignment of fracture segments involving bony irregularity or bony displacement. These evaluations were used to separate postoperative outcomes into 5 groups: excellent, good, fair, poor, and very poor. Results: Immediate postoperative nasal shape was excellent in 10 cases, good in 31 cases, fair in 8 cases, and poor results in a single case. Postoperative shape at one month was excellent in 37 cases, good in 12 cases, fair in a single case. Conclusion: The overall shape of nasal bone after fracture reduction tended to improve with passage of time.

Pose alignment control of robot using polygonal approximated gripper images (다각 근사화된 그리퍼 영상을 이용한 로봇의 위치 정렬)

  • Park, Kwang-Ho;Kim, Nam-Seong;Kee, Seok-Ho;Kee, Chang-Doo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.559-563
    • /
    • 2000
  • In this paper we describe a method for aligning a robot gripper using image information. The region of gripper is represented from HSI color model that has major advantage of brightness independence. In order to extract the feature points for vision based position control, we find the corners of gripper shape using polygonal approximation method which determines the segment size and curvature of each points. We apply the vision based scheme to the task of alignment of gripper to reach the desired position by 2 RGB cameras. Experiments are carried out to exhibit the effectiveness of vision based control using feature points from polygonal approximation of gripper.

  • PDF

An improved electrode structure of the Patterned Vertical Alignment Liquid Crystal Cell for high optical property

  • Choi, Yong-Hyun;Son, Jung-Hee;Yang, Jin-Seok;Ji, Seung-Hoon;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.502-505
    • /
    • 2007
  • In this paper we propose a novel electrode structure for high transmittance in the Patterned Vertical Alignment (PVA) LC cell. Normally, the transmittance of PVA LC cell is depended on the shape of the electrode and cell gap. We studied the area decreasing the transmittance through the electrode structure for wide viewing angle and proposed new electrode design to change LC director configuration in the area. We use the 'TechWiz LCD' for calculation of the director configuration and optical characteristics. We show the comparison of the calculated optical transmittance between the conventional PVA mode and the proposed PVA mode. From the results, we confirm that the optical transmittance of the proposed structure of the PVA cell becomes higher.

  • PDF

Trial Installation and Performance Evaluation of Prefabricated Concrete Slab Track on Revenue Line (프리캐스트 콘크리트 슬래브궤도의 영업선 시험시공 및 성능평가)

  • Jang, Seung-Yup;Kang, Yun-Suk;Lee, Hu-Sam;Kim, Yu-Bong;Lee, Jong-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.840-845
    • /
    • 2008
  • To develop our original technology of concrete slab track, being widely accepted for new track, prefabricated concrete slab track, or precast concrete slab track has been developed. They have two different types according to slab shape and its dimensions, connection of slabs and connecting structure onto substructure. After the system design and successful performance evaluation in the laboratory, the trial installation on revenue line has been carried out. This paper is presenting the result of the trial installation and the performance tests in field. The performance tests have been performed as visual inspection for cracks and damages, measurement of track alignment and elastic behavior of track under passing trains. The performance test results during last 2 years have shown that no remarkable damages and settlements were found, and track alignment and elastic track behavior both exhibits good status.

  • PDF

Processing Control of 0402 Chip used Pb-free Solder in SMT process (무연솔더 적용한 0402 칩의 공정제어)

  • Bang, Jeong-Hwan;Lee, Chang-U;Lee, Jong-Hyeon;Kim, Jeong-Han;Nam, Won-U
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.218-221
    • /
    • 2007
  • The surface mounting technology of 0402 electric chip part is necessary to fabricate a high density and multi-functional module, but there is a limitation of the technology, like as a bridge and self-alignement. This work estimated SMT processing factors of 0402 chip. To obtain optimum SMT process, we evaluated effects of stencil thickness, shape of hole on printability and mountability. Printability shows best results under the thickness of $80{mu}m$ with circle hole shape and 90% square hole shape. In case of chip mounting process, chip mis-alignment and bridge was occurred rarely in same conditions. In more thin stencil thickness, $50{mu}m$, strength of 1005 chip parts was poor, because of amount of printed solder was insufficient.

  • PDF

Electro-optical characteristics of PVA (Z-shape) mode using the UV curable reactive mesogen (RM) (광경화성 단분자를 이용한 Z-shape PVA 모드에서의 투과율 향상에 관한 연구)

  • Cho, In-Young;Hwang, Seong-Jin;Kim, Sung-Min;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.437-438
    • /
    • 2008
  • The Conventional patterned vertical alignment (PVA) device shows a very high contrast ratio at normal direction and does not require rubbing process. However it has a disclination area in which the liquid crystal can be collision in the boundary domain region. In this paper, we studied PVA(Z-shape) device in which the liquid crystal can be tilted down in multiple directions stably because the surface pretilt angle is controlled by photopolymerization of the UV - curable reactive mesogen (RM) under a proper condition. Consequently, the device shows improved electro optical properties as compared to conventional PVA mode.

  • PDF

Perception of maxillary anterior esthetics by dental professionals and lay people and topographical tooth-gingiva interface (한국인의 상악 전치부 심미 인지 선호도 및 정상 치은의 형태 분포)

  • An, Ki-Yeon;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.817-827
    • /
    • 2006
  • Purpose : This study was designed 1) to compare the perception of dental professionals and lay people with respect to minor variations in maxillary anterior tooth size and alignment and their relation to the surrounding soft tissues, and 2) to evaluate the normal tooth-gingiva topographical relationships in periodontally healthy young subjects, Materials and methods : Maxillary anterior teeth were intentionally diagrammed in varying degree of deviation with respect to one of three common anterior esthetic discrepancies including variations in crown length, shape of gingival margin, and length of interproximal contact, 17 images were generated to be preferentially selected by 2 groups consisting of dental professionals and lay people (total of 740). Smiling photographs of 120 dental students who had healthy periodontium were taken and the photographic images were analyzed to be classified as 17 kinds of altered image groups. Results : The results demonstrated noticeable difference between the varying levels of discrepancy. Both group preferred gingival margin of lateral incisor to be 0.5mm lower than that of central incisor. Lay people preferred the gingival margin shape that has 2/9 horizontal component of the crown width, while dental professionals preferred the gingival margin shape that has 1/9 horizontal component of the crown width. Lay people preferred longer length of the interproximal contact (two thirds of the crown length), whereas dental professionals preferred shorter length of the interproximal contact (half of the crown length). Photographic analysis of normal esthetic gingival topography revealed 2/9 horizontal component and short length of the interproximal contact which was of the hybrid nature of the preferences shared by lay people and dental professionals. Conclusion: The results of this study show that dental professionals and lay people demonstrated significant difference in their preference of dental esthetic components, which may then influence the decision making process by dental professionals with respect to designing the anterior esthetic gingival line.