• 제목/요약/키워드: Shallow and Deep Dose

검색결과 12건 처리시간 0.026초

Rice Bran Application under Deep Flooding can Control Weed and Increase Grain Yield in Organic Rice Culture

  • Yan, Yong-Feng;Fu, Jin-Dong;Lee, Byun-Woo
    • Journal of Crop Science and Biotechnology
    • /
    • 제10권2호
    • /
    • pp.79-85
    • /
    • 2007
  • Rice bran application just after transplanting has been increasingly practiced as an herbicide-substitute for organic rice production in Korea. However, this practice is frequently reported to be unsatisfactory in weed suppression. An experiment with five treatments that combines flooding depth, rice bran application dose, and herbicide treatment was done in the paddy field to evaluate whether rice bran application under deep flooding can lead to a successful weed control in compensation for the single practice of rice bran application. Rice bran was broadcasted on the flood water surface just after deep flooding of 8 to 10cm that was started at seven days after transplanting. In the shallow flooding plot without herbicide six weed species were recorded: Monochoria vaginalis, Echinochloa crus-galli, Ludvigia prostrate, Cyperus amuricus, Aneima keisak, and Bidens tripartite. Among the first four dominant weed species, deep flooding significantly suppressed the occurrence of Echinochloa crus-galli and Cyperus amuricus while did not suppress the occurrence of Monochoria vaginalis and Ludwigia prostrate. On the contrary, rice bran application under deep flooding suppressed significantly Monochoria vaginalis and Ludwigia prostrate while didn't exert an additional suppression of Echinochloa crus-galli and Cyperus amuricus compared to deep flooding alone. Rice bran application and deep flooding suppressed complimentarily all the six weed species to a satisfactory extent except for Monochoria vaginalis of which suppression efficacy was 31.9%. Deep flooding reduced the panicle number substantially by inhibiting the tiller production, increased the spikelet number per panicle slightly, and leaded to a lower rice grain yield compared to shallow flooding with herbicide. Rice bran application under deep flooding mitigated the panicle reduction due to deep flooding, increased the spikelets per panicle significantly, and thus produced even higher grain yield in the rice bran application of 2000kg $ha^{-1}$ as compared to the shallow flooding treatment with herbicide. In conclusion, this practice applying rice bran under deep flooding would be promising to be incorporated as an integral practice for an organic rice farming system.

  • PDF

방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구 (A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권2호
    • /
    • pp.249-255
    • /
    • 2023
  • 본 연구는 방사선작업종사자, 방사선관계종사자 그룹의 방사선사들과 수시출입자로 분류된 예비 방사선사인 재학생의 임상실습 과정에서의 피폭선량을 측정하였다. 2021년 1월부터 1년 동안 인천소재의 C 대학병원의 방사선구역에서 근무하였던 방사선사들과 동 의료기관에서 7월 1일부터 8월 31일까지 임상실습을 이수한 121명의 학생들을 연구대상으로 하였다. 방사선 피폭선량으로 인하여 손상위험장기인 폐의 피폭선량으로 인한 부작용 발생확률을 평가하기 위하여 ICRP 103[12]에 의거한 명목위험계수(Nominal Risk Factor)를 사용하였다. 임상실습기간 중 수시출입자로 분류된 방사선(학)과 학생들의 표층선량은 0.98 ± 0.14 mSv, 심부선량은 0.93 ± 0.14 mSv였다. 즉, 표층선량은 1,000,000당 6.7명, 심부선량은 6.4명이 폐의 피폭선량으로 인한 부작용 발생률이 있음이 나타났다. 이는 1년 피폭선량의 환산 값으로 방사선(학)과 교육과정이 3년 혹은 4년임을 고려하였을 때, 임상실습을 나가는 예비 방사선종사자들에 대한 체계적인 관리와 관심이 필요하며, 방사선의 확률적 영향과 관련하여 방사선 안전관리를 위한 기초자료로 활용될 것으로 사료된다.

방사성물질과 접촉하는 작업의 손·발이 받는 피폭방사선량 평가에 대한 고찰 (A Review of Radiation Field Characteristics and Field Tests for Estimating on the Extremity Dose under Contact Tasks with Radioactive Materials)

  • 김희근;공태영;동경래;최은진
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.123-130
    • /
    • 2017
  • Concerns about high radiation exposure to the hands of radiation workers who may contact with radioactive contamination on surfaces in a nuclear power plant (NPP) had been raised, and the Korean regulatory body required the extremity dose estimation during contact tasks with radioactive materials. Korean NPPs conducted field tests to identify the incident radiation to the hands of radiation workers who may contact with radioactive contamination during maintenance periods. The results showed that the radiation fields for contact tasks are dominated by high energy photons. It was also found that the radiation doses to the hands of radiation workers in Korean NPPs were much less than the annual dose limits for extremities. This approach can be applicable to measure and estimate the extremity dose to the hands of medical workers who handle the radioactive materials in a hospital.

140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가 (Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield)

  • 김지영;이왕희;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

300 keV 중성자(中性子)에 대한 방사선량(放射線量) 관계량(關係量)의 산정(算定) (Dosimetric Quantities for 300 keV Neutrons)

  • 이수용
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.37-43
    • /
    • 1986
  • ICRU 구(球)를 피사체(被射體)로 하여 300 keV 중성자(中性子)의 방사선량(放射線量) 관계량(關係量)을 평가(評價)하였다. 피사체내(被射體內)의 선량당량(線量當量) 분포(分布)를 직접(直接) 산정(算定)하기 위해 중성자(中性子)-광자(光子)-하전입자(荷電粒子) 결합수송(結合輸送)을 다룰 수 있는 몬테칼로 코드 NEDEP을 사용하였다. 계산결과(計算結果) 얻은 방사선량(放射線量) 관계량(關係量)은 다음과 같다. 심부선량당량지수(深部線量當量指數) $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ 표층선량당량지수(表層線量當量指數) $H_{I,s}:2.08{\times}10^{-1}\;Sv-cm^2$ 주위선량당량(周圍線量當量) $H^*(0.07):1.70{\times}10^{-11}\;Sv-cm^2$ 주위선량당량(周圍線量當量) $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ 실효선질계수(實效線質係數) $\bar{Q}^*(10):12.4$

  • PDF

일개 대학병원의 수시출입자와 방사선작업종사자의 피폭선량에 관한 고찰 (A Study on the Exposure Dose of Frequent Workers and Radiation Workers in a University Hospital)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.581-587
    • /
    • 2023
  • 본 연구에서는 인천 C대학병원에서 방사선작업종사자와 수시출입자의 피폭선량을 비교 분석하여 방사선 안전관리를 위한 기초 자료를 제공하고자 하였다. 2021년 1월부터 2022년 12월까지 인천 소재 C대학병원에서 근무하는 방사선작업종사자 30명과 수시출입자 8명을 대상으로 표면선량과 심부선량을 분석하였다. 방사선작업종사자는 방사선종양학과와 핵의학과에서 근무하는 방사선사 및 간호사를 대상으로 하였으며, 수시출입자는 동일 방사선관리구역 내 시설관리 및 청소업무를 수행하는 수시출입자를 대상으로 하였다. 방사선작업종사자는 방사선사 100,000당 3.1명, 간호사 100,000당 1.2명, 수시출입자 1,000,000당 4.5명이 폐에 부작용이 생길 가능성을 보였다. 방사선종양학과의 방사선사는 10,000당 1.1명, 간호사의 경우 1,000,000명당 5.2명이었고, 핵의학과의 방사선사는 10,000명당 2.9명, 간호사의 경우 1,000,000명당 7.1명이었다. 본 연구가 향후 수시출입자에 관한 개정 시 기초자료로 활용될 수 있기를 바라며, 향후 방사선의 확률론적 영향과 관련된 장해 분야의 기초자료로 활용될 수 있을 것으로 생각된다.

원전 계획예방정비기간 고피폭 접촉작업에서 방사선작업종사자의 말단선량 평가 현장시험 (A Field Test Assessment on the Extremity Doses of Highly-Exposed Radiation Workers During Maintenance Periods at Nuclear Power Plants in Korea)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.57-62
    • /
    • 2010
  • 원전 계획예방정비기간 증기발생기 수실작업, 가압기 전열관교체 또는 압력관피더 제거작업 지역 등은 높은 방사선량률을 보이는 지역으로, 짧은 시간 동안의 작업으로 작업종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉하는 손 부위는 높은 피폭이 일어날 수 있다. 이런 점을 고려하여 국내 가압경수로원전과 가압중수로원전의 계획 예방정비기간 중 증기발생기 수실 노즐댐 설치와 제거작업, 원자로 냉각재펌프 보수작업, 원자로헤드 보수 및 검사작업 등과 같은 고피폭 접촉작업에서 방사선작업종사자의 말단선량을 측정하기위한 현장시험을 실시하였다. 여기에 참여한 작업종사자는 가슴과 등 부위에 일상적인 절차에 따른 복수선량계를 패용한 것 이외에 손목에 개인선량계를 추가로 패용하였고, 손가락 부위에는 말단선량계 (Extremity dosimeter)를 패용하였다. 그 결과, 손가락이 받는 등가선량은 각각 손목이 받는 등가선량 및 가슴 또는 등 부위가 받는 등가선량과 일정한 비율로 평가됨을 확인하였다.

원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석 (An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.176-183
    • /
    • 2009
  • 원전 계획예방정비기간 증기발생기 수실작업 등은 매우 높은 방사선량율을 보이는 지역으로, 짧은 시간 동안 작업으로 종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉작업을 하는 손 부위에서 고피폭이 예상된다. 이런 점을 고려하여 2004년 수행된 국내 원전의 복수선량계 알고리즘 적용성 시험의 TLD 판독결과를 이용하여 고피폭 접촉 작업의 방사선장을 분석하였다. 그 결과, 원전 고피폭 접촉작업의 입사방사선장은 고에너지 광자(High Energy Photon Field)에 의한 피폭으로 해석되었다. 한편 2009년 울진 4호기 계획예방정비기간 S/G 정비작업과 월성 1호기 압력관 교체작업에 참여한 방사선작업종사자에 대해 말단선량 현황과 방사선장을 분석하기위한 현장시험을 실시하였다. 그 결과 입사방사선장은 고에너지 방사선장으로 확인되었다.

일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석 (A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital)

  • 양남희;정운관;동경래;최은진;주용진;송하진
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.

개인방사선 피폭선량판독 성능시험 (Personnel Dosimetry Performance Test)

  • 나성호;한승재;이두희;조대형
    • Journal of Radiation Protection and Research
    • /
    • 제21권2호
    • /
    • pp.131-138
    • /
    • 1996
  • 본 논문에서는 1995년에 시행된 우리나라 최초의 개인선량판독 성능시험에 대한 방법 및 결과들을 기술하고 있다 성능시험은 ANSI N13.11-1993의 방법중 중성자를 제외한 7개의 범주에 한하여 실시하였다. 시험에 참가한 개인선량계는 1:l개 판독기관으로 부터 15종류이었다 한 종류 별로 총129개의 선량계가 제출되었는데 이는 한 범주 별로 15개씩 7범주와.24개의 컨트롤을 합한 것이다. 재시험을 포함한 총 시험범주 수는 144개이었고 제출된 선량계 수는 컨트롤 400개를 포함하여 총 2560개이었다. 이는 한 범주별로 15개씩 7개 범주와 15종류에 소요된 것과 재시험을 위한 39범주에 소요된 선량계 수를 합한 것이다. 절차서에 따라 결정된 각 범주의 성능지수는 판독선량과 부여선량으로 편중 값의 절대치와 표준편차의 합으로 계산되었다. 만약 어느 범주의 심부 또는 표층 선량당량(흡수선량)의 성능지수가 0.5 미만일 경우에는 해당범주는 합격으로 평가되었다. 시험결과 첫 번째 성능시험에서 전 범주를 합격한 기관은 전체의 54%. 두 번째 시험에서는 전체의 33% 그리고 세 번째 시험에서는 전체의 13%로 나타났다.

  • PDF