• Title/Summary/Keyword: Shaft fracture

Search Result 156, Processing Time 0.018 seconds

Rare Imaging of Fat Embolism Seen on Computed Tomography in the Common Iliac Vein after Polytrauma

  • Lee, Hojun;Moon, Jonghwan;Kwon, Junsik;Lee, John Cook-Jong
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.103-106
    • /
    • 2018
  • Fat embolism refers to the presence of fat droplets within the peripheral and lung microcirculation with or without clinical sequelae. However, early diagnosis of fat embolism is very difficult because the embolism usually does not show at the computed tomography as a large fat complex within vessels. Forty-eight-year-old male with pedestrian traffic accident ransferred from a local hospital by helicopter to the regional trauma center by two flight surgeons on board. At the rendezvous point, he had suffered with dyspnea without any airway obstruction sign with 90% of oxygen saturation from pulse oximetry with giving 15 L of oxygen by a reserve bag mask. The patient was intubated at the rendezvous point. The secondary survey of the patient revealed multiple pelvic bone fracture with sacrum fracture, right femur shaft fracture and right tibia head fracture. Abdominal computed tomography was performed in 191 minutes after the injury and fat embolism with Hounsfield unit of -86 in his right common iliac vein was identified. Here is a very rare case that mass of fat embolism was shown within common iliac vein detected in computed tomography. Early detection of the fat embolus and early stabilization of the fractures are essential to the prevention of sequelae such as cerebral fat embolism.

Comparison of mechanical properties of nickel-titanium rotary files: Aurum Blue vs. Aurum Pro (니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro)

  • Kwak, Sang Won;Ha, Jung-Hong;Ahn, Sang Mi;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.672-678
    • /
    • 2019
  • AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

  • PDF

Intramedullary Nailing versus Minimally Invasive Plate Osteosynthesis for Distal Tibia Shaft Fractures: Retrospective Comparison of Functional and Cosmetic Outcomes (경골 원위간부 골절 치료의 골수강내 금속정 고정술과 최소침습 금속판 고정술의 비교: 기능적, 미용적 결과의 후향적 비교)

  • Kahyun Kim;In Hee Kim;Geon Jung Kim;SungJoon Lim;Ji Young Yoon;Jong Won Kim;Yong Min Kim
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.3
    • /
    • pp.93-98
    • /
    • 2023
  • Purpose: This study compared the functional and cosmetic treatment outcomes of intramedullary nailing (IM nail) and minimally invasive plate osteosynthesis (MIPO) for distal tibia shaft fractures. Materials and Methods: Forty-eight patients with distal tibia shaft fractures (distal 1/3 of the diaphysis, AO/OTA [AO Foundation/Orthopaedic Trauma Association]) 43 managed by an IM nail (n=30) or MIPO (n=18) who had minimum one-year follow-up were enrolled in this study. The radiological, functional, and cosmetic outcomes in the two groups were compared retrospectively. Results: All patients achieved bone union. The mean bone union time of the IM nail and MIPO groups was 18.5 and 22.6 weeks, respectively (p=0.078). One patient in the MIPO group showed posterior angulation and valgus deformity of more than five degrees. The mean American Orthopaedic Foot and Ankle Society (AOFAS) functional scores were similar: 83.3 in the IM nail group and 84.6 in the MIPO group (p=0.289). The most salient difference was the cosmetic result of the surgical scar. The length of the scars around the ankle in the IM nail group was significantly smaller than the MIPO group (2.6 cm vs. 10.6 cm; p=0.035). The patient satisfaction survey of surgical scars revealed a significantly higher satisfaction rate in the IM nail group than in the MIPO group (93% vs. 44%; p<0.001). Conclusion: This study showed that both treatment methods for distal tibia shaft fractures have similar therapeutic efficacy regarding the radiological and functional outcomes. On the other hand, the IM nail technique showed superior cosmetic outcomes than the MIPO technique. IM nails may be more recommended in patients with high demand for cosmetic results.

A Study on the Surface Roughness of Ceramics According to Ultrasonic Polishing (초음파 폴리싱 가공에 따른 세라믹재료의 표면거칠기에 관한 연구)

  • Moon, Hong-Hyun;Park, Byung-Gyu;Lee, Chan-Ho;KIm, Sung-Chung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.1
    • /
    • pp.15-21
    • /
    • 2003
  • The ultrasonic polishing machine was developed to get super finishing that consist of machine part that can rotate and travel the main shaft with power 1.5kW, ultrasonic generator with frequency 20kHz. By using this machine we were investigated the characteristics of ultrasonic polishing for three different ceramics, and so could be obtained following results. First, we could be obtained the excellent surface for hard-ta-difficult cutting materials. Second, the effect of surface roughness for the feed rate could be shown that the more the feed rate Increases, the more the value of surface roughness increases. Third, owing to the characteristics being progressed brittle fracture in $Al_2O_3$ polishing with this machine, the value of surface roughness is larger than other ceramics. Forth, because the ultrasonic polishing can be smoother than the existing grinding in discharging the chips, it could be possible to improve the surface roughness about up to 15%.

  • PDF

Massive traumatic abdominal wall hernia in pediatric multitrauma in Australia: a case report

  • Sarah Douglas-Seidl;Camille Wu
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.447-450
    • /
    • 2023
  • Traumatic abdominal wall hernia is a rare presentation, most commonly reported in the context of motor vehicle accidents and associated with blunt abdominal injuries and handlebar injuries in the pediatric population. A 13-year-old boy presented with multiple traumatic injuries and hemodynamic instability after a high-speed motor vehicle accident. His injuries consisted of massive traumatic abdominal wall hernia (grade 4) with bowel injury and perforation, blunt aortic injury, a Chance fracture, hemopneumothorax, and a humeral shaft fracture. Initial surgical management included partial resection of the terminal ileum, sigmoid colon, and descending colon. Laparostomy was managed with negative pressure wound therapy. The patient underwent skin-only primary closure of the abdominal wall and required multiple returns to theatre for debridement, dressing changes, and repair of other injuries. Various surgical management options for abdominal wall closure were considered. In total, he underwent 36 procedures. The multiple injuries had competing management aims, which required close collaboration between specialist clinicians to form an individualized management plan. The severity and complexity of this injury was of a scale not previously experienced by many clinicians and benefited from intrahospital and interhospital specialist collaboration. The ideal aim of primary surgical repair was not possible in this case of a giant abdominal wall defect.

Effect of Surgical-Site, Multimodal Drug Injection on Pain and Stress Biomarkers in Patients Undergoing Plate Fixation for Clavicular Fractures

  • Yoo, Jae-Sung;Heo, Kang;Kwon, Soon-Min;Lee, Dong-Ho;Seo, Joong-Bae
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.455-461
    • /
    • 2018
  • Background: Surgical-site, multimodal drug injection has recently evolved to be a safe and useful method for multimodal pain management even in patients with musculoskeletal trauma. Methods: Fifty consecutive patients who underwent plating for mid-shaft and distal clavicular fractures were included in the study. To evaluate whether surgical-site injections (SIs) have pain management benefits, the patients were divided into two groups (SI and no-SI groups). The injection was administered between the deep and superficial tissues prior to wound closure. The mixture of anesthetics consisted of epinephrine hydrochloride (HCL), morphine sulfate, ropivacaine HCL, and normal saline. The visual analogue scale (VAS) pain scores were measured at 6-hour intervals until postoperative hour (POH) 72; stress biomarkers (dehydroepiandrosterone sulfate [DHEA-S], insulin, and fibrinogen) were measured preoperatively and at POH 24, 48, and 72. In patients who wanted further pain control or had a VAS pain score of 7 points until POH 72, 75 mg of intravenous tramadol was administered, and the intravenous tramadol requirements were also recorded. Other medications were not used for pain management. Results: The SI group showed significantly lower VAS pain scores until POH 24, except for POH 18. Tramadol requirement was significantly lower in the SI group until POH 24, except for POH 12 and 18. The mean DHEA-S level significantly decreased in the no-SI group ($74.2{\pm}47.0{\mu}g/dL$) at POH 72 compared to that in the SI group ($110.1{\pm}87.1{\mu}g/dL$; p = 0.046). There was no significant difference in the insulin and fibrinogen levels between the groups. The correlation values between all the biomarkers and VAS pain scores were not significantly different between the two groups (p > 0.05). Conclusions: After internal fixation of the clavicular fracture, the surgical-site, multimodal drug injection effectively relieved pain on the day of the surgery without any complications. Therefore, we believe that SI is a safe and effective method for pain management after internal fixation of a clavicular fracture.

Long-term outcomes of initially conservatively treated midshaft clavicle fractures

  • Lee, Gwan Bum;Kim, Hyojune;Jeon, In-Ho;Koh, Kyoung Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Background: Recent studies about completely displaced midshaft clavicle fractures have reported that their nonunion/malunion rates were significantly higher in conservatively treated patients compared to surgically treated patients. The purpose of this study was to evaluate the factors associated with treatment decisions for midshaft clavicle fractures and also the factors that affect patient satisfaction with their treatment choice. Methods: We retrospectively reviewed the records of 75 patients who had been diagnosed with a midshaft clavicle fracture and were treated conservatively at a single institution between March 1, 2013, and December 31, 2014. Their medical records were reviewed to investigate the severity of the initial vertical displacement. A telephone survey was carried out to identify the presence of any patient-perceived deformity and determine if the patient eventually underwent surgery and whether the patient would prefer surgery if the injury recurred. Results: Significantly more patients with vertical displacement ≥100% (9/28) eventually underwent surgery compared to patients with vertical displacement <100% (3/32, p=0.028). Patients with vertical displacement ≥100% (13/28) were significantly more likely to prefer surgery compared to patients with vertical displacement <100% (7/32, p=0.044). Among the conservatively treated patients, nine of 32 participants with a patient-perceived deformity and one of 16 without a patient-perceived deformity responded that they would prefer to receive surgery in same situation in the future (p=0.079). Conclusions: Patients with a midshaft clavicle fracture with vertical displacement of ≥100% may eventually require surgical treatment. When conservative treatment is carried out, the long-term patient results may be unsatisfactory due to perceived residual deformities.

Femur Fractures Associated with Benign Bone Tumors in Children (양성 골종양을 동반한 소아 대퇴골의 병적 골절)

  • Jung, Sung-Taek;Kim, Byung-Soo;Moon, Eun-Sun;Lee, Keun-Bae;Seo, Hyoung-Yeon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2005
  • Purpose: We evaluate the results of treatment of pathologic femur fractures secondary to bone tumors in children. Materials and Methods: Between January 1995 and June 2004, 18 patients(20 cases) were evaluated. Their mean age of the first episode of fracture was 10.2 years and mean follow-up period is 42.5 months. Primary bone tumors, the location of fracture, time to union and complications were evauated. Results: Fractures occurred at proximal portion in 14 cases, shaft 3 cases and distal portion 3 cases. The bone tumors causing pathologic fracture were fibrous dysplasia(9 c ases), simple bone cyst(4 cases), aneurysmal bone cyst(4 cases), nonossifying fibroma(2 cases) and eosinophilic granuloma(1 case). In the treatment for fractures, cast was in 11 cases, internal fixation 8 cases and external fixation in 1 case. In the treatment for tumors, observation was in 11 cases, curettage & bone graft in 8 cases and resection in 1 case. In polyostotic fibrous dysplasia, all cases were treated by cast initially but deformity developed in all cases. Fracture prevention and deformity correction were obtained with intramedullary nailing. Conclusion: Adequate choice of treatment of bone tumor and fracture will result in good prognosis.

  • PDF

Operative Treatment of the Clavicular Midshaft Fractures in Adult - A Comparison between Intramedullary Multiple Steinmann Pins Fixation and Reconstruction Plate Fixation - (성인 쇄골 간부 골절의 수술적 치료-골수강내 다발성 Steinmann핀 고정술과 재구성 금속판 고정술과의 비교-)

  • Lee Young Kuk;Gu Hae Seo
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.14-20
    • /
    • 1999
  • Purpose: Despite of the popular use of the reconstruction plate for the fixation of clavicular shaft fractures, some disadventages have been raised such as long period of immobilization, long skin incision, loosening of plate and screws, and increased chance of nonunion due to severe periosteal injury. Thus, the authors have performed intramedullary multiple Steinmann pins fixation that could reduce the disadvantages of plate fixation in order to compare the treatment results between the two groups. Materials & Methods: From 1994. Jan. to 1997. Dec. the department of orthopaedic surgery of the Kwak's hospital treated operatively for 56 cases of the clavicular shaft fractures in adult. 39 cases of them were treated with the plate fixation and 17 cases with the intramedullary multiple Steinmann pins fixation(SP group). Reconstruction plates(Plate group) were used for 26 out of 39 patients treated with plate fixation. Among the Plate group and SP group, each 15 cases were selected by age and sex and compared each other according to the bone union time, union rate, complication, and functional results. The follow-up period was 12 months at the shortest and 48 months at the longest and the average was 16 months. Results: The Plate group showed that the bone union time was 7 weeks and the bone union rate was 93%. The SP group showed 6.5 weeks and 100% respectively. In complication, the Plate group had 1 case of loosening of plate and screws and delayed union; SP group had 1 case of pin migration. The functional results according to Kang's criteria, 87% of the Plate group and 93% of the SP group showed good or excellent. Conclusion : The SP group showed very comparable results in terms of the bone union time, bone union rate, complication, and functional results comparing to the Plate group. The intramedullary multiple Steinmann pins fixation showed several advantages over the reconstruction plate fixation, which were simple operative technique, easy removal of pins, being able to perform immediate postoperative full range of motion exercise. Therefore, the intramedullary multiple Steinmann pins fixation is thought to be one of the useful operative techniques in treatment of the clavicular shaft fractures in adult.

  • PDF

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.