• Title/Summary/Keyword: Shaft Generator

Search Result 146, Processing Time 0.033 seconds

Multi-Body Dynamic Response Analysis of a MW-Class Wind Turbine System Considering Rotating and Flexibility (로터 회전 및 타워의 탄성력을 고려한 MW 급 풍력발전기의 비선형 다물체 동적 응답 해석)

  • Kim, Dong-Man;Kim, Dong-Hyun;Kim, Yo-Han;Kim, Su-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.78-83
    • /
    • 2009
  • In this study, computer applied engineering (CAE) techniques are fully used to conduct structural and dynamic analyses of a whole huge wind turbine system including composite blades, tower and nacelle. For this study, computational fluid dynamics (CFD) is used to predict aerodynamic loads of the rotating wind-turbine blade model. Multi-body dynamic structural analyses are conducted based on the non-linear finite element method (FEM) by using super-element method for composite laminates blade. Three-dimensional finite element model of a wind turbine system is constructed including power train(main shaft, gear box, coupling, generator), bedplate and tower. The results for multi-body dynamic simulations on the wind turbine's critical operating conditions are presented in detail.

  • PDF

Study of Dynamic Characteristics of Angular Misalignment of High-pressure Turbine in 1000MW Nuclear Power Plant (축정렬 불량시 베어링 특성 변화에 따른 발전소 증기 터빈의 동특성 연구)

  • Sohn, Seok-Man;Lee, Jun-Shin;Yoo, Ki-Wan;Lee, Sun-Ki;Kim, Tae-Ryong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.664-669
    • /
    • 2000
  • Angular misalignment is one of the important causes for shaft vibration of turbine-generator in 1000MW nuclear power plant. It may cause the plant unexpected shutdown and subsequent accident. The change of dynamic characteristics in journal bearing and rotor due to angular misalignment in high pressure turbine is analyzed. The stiffness/damping coefficients of journal bearing increase as angular misalignment. Subsequently the natural frequency of HP turbine is changed. It was found that the natural frequency may locate near 2 times operating frequency in case of severe misalignment.

  • PDF

A study on the overhaul method for a Tandem type EDG on Nuclear Power Plant (원자력발전소 Tandem 형 비상디젤발전기의 최적 정비 방안 연구)

  • Han, Sung-Heum;Lim, Woo-Sang;Ha, Che-Wung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2036-2037
    • /
    • 2008
  • An Emergency Diesel Generator (EDG) manufactured by a French company Wartsila SACM, is a tandem type engine, consisted of two 10 cylindered diesel engines on each side. Manual provided by the manufacturer states that engine bearing requires inspection every 15 years. However, it is difficult for an inspector to access through a manhole located in the lower compartment of engine. Furthermore, during a routine or scheduled maintenance, it is not possible to disassemble main engine bearing and crank shaft, and perform inspection. Two methodologies are suggested here to resolve the problem. One method is to lift the engine and partially perform the maintenance service, and the other method is to disassemble the engine completely and to perform maintenance service by the manufacturer. Pros and cons of two methodologies were thoroughly compared.

  • PDF

Horizontal-Axis Wind Turbine System Modeling using Multi-body Dynamics (다몸체 역학을 이용한 수평축 풍력발전 시스템 모델링)

  • 민병문;노태수;송승호;최석우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • In this paper, an efficient modeling method of Horizontal-Axis Wind Turbine(HAWT) system is proposed. This method Is based on representing a HAWT system as a multi-body system with several rigid bodies i.e. rotor blade, low/high speed shaft, gear system, md generator. Also, simulation software WINSIM is developed to evaluate performance of wind turbine system. Simulation results show that the proposed modeling method and simulation software are efficient and reliable.

Hydraulic Constant Frequency Generation System Driven by Main Engine for Small Fishing Boat - Hydraulic Pump Control Type - (소형 어선용 주기구동 유압식 고주파수 발전장치에 관한 연구 ( 1 ) - 유압펌프 제어방식 -)

  • Lee, Il-Yeong;Park, Sang-Gil;Jeong, Yong-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.30-35
    • /
    • 1988
  • An electrical power generation system driven by main engine shaft, briefly SG system for middle or small size fishing boat is studied experimently. In the SG system, power transmission is performed by a variable displacement hydraulic pump driven by the main engine and a constant displacement hydraulic motor. It was verified that the SG system enabled the generation of electrical power with constant frequency regardless main engine speed. In the SG system, setting reference frequency, sensing generator output frequency and setting controller parameters are performed by performed by programming in a microcomputer, so a countermeasure for physical situations of control object is very easy. Futhermore, the SG system has following features; low initial installation cost, wide freedom of installation in engine room, advantage of application in existing ships, especially fishing boat with hydraulic fishing equipments.

  • PDF

A Study of Axial Vibration of Two Stroke Low Speed Diesel Engine on the Diesel Power Plant (육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구)

  • 이돈출;남정길;고재용
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.398-405
    • /
    • 2001
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been increased comparing to that of the previous one. So the axial vibration damper in standard one is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits. In this paper, the optimum design of axial vibration on the 65 kW diesel power plant with tow 9K80MC-S engines of 9 cylinders was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

A Method of Fault Diagnosis for Engine Synchronization Using Analytical Redundancy (해석적 중복을 이용한 내연 기관 엔진의 동기화 처리 이상 진단)

  • 김용민;서진호;박재홍;윤형진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.89-95
    • /
    • 2003
  • We consider a problem of application of analytical redundancy to engine synchronization process of spark ignition engines, which is critical to timing for every ECU process including ignition and injection. The engine synchronization process we consider here is performed using the pulse signal obtained by the revolution of crankshaft trigger wheel (CTW) coupled to crank shaft. We propose a discrete-time linear model for the signal, for which we construct FDI (Fault Detection & Isolation) system consisting residual generator and threshold based on linear observer.

Analysis of Operation Performance of a Micro Gas Turbine Generator System (마이크로 가스터빈 발전시스템의 운전성능 분석)

  • Lee, J. J.;Kim, T S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.132-139
    • /
    • 2004
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. On the basis of the measured data, analytical approach is tried to estimate design characteristic and performance parameters such as component efficiencies and unmeasured temperatures.

  • PDF

Grid Generation and flow Analysis around a Twin-skeg Container Ship (Twin-skeg형 컨테이너선 주위의 격자계 생성과 유동 해석)

  • 박일룡;김우전;반석호
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.1
    • /
    • pp.15-22
    • /
    • 2004
  • Twin-skeg type stern shapes are recently adopted for very large commercial ships. However it is difficult to apply a CFD system to a hull form having twin-skeg, since grid topology around a twin-skeg type stern is more complicated than that of a conventional single-screw ship, or of an open-shaft type twin-screw ship with center-skeg. In the present study a surface mesh generator and a multi-block field grid generation program have been developed for twin-skeg type stern. Furthermore, multi-block flow solvers are utilized for potential and viscous flow analysis around a twin-skeg type stern The present computational system is applied to a 15,000TEU container ship with twin-skeg to prove the applicability. Wave profiles and wake distribution are calculated using the developed flow analysis tools and the results are compared with towing tank measurements.

Performance Analysis of Orbiter Vacuum Pump (오비터 진공펌프 성능해석)

  • Kim, Hyun-Jin;Shim, Jae-Hwi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.28-35
    • /
    • 2006
  • Orbiter mechanism has been applied to vacuum pump design for small oxygen generator where low vacuum of about 200 mmHg is required. Performance of the designed vacuum pump has been numerically investigated: calculated volumetric and adiabatic efficiencies were 69.7% and 83.9%, respectively for leakage clearance of $10{\mu}m$. Total efficiency of the orbiter vacuum pump was 77.5%. At the shaft speed of 1700 rpm suction displacement volume of 6.3cc provided discharge flow at the rate of 2.3 liter/min with power consumption of 10.1Watt. Torque variation of the orbiter pump was only about 20% of that of diaphragm pump.