• 제목/요약/키워드: Shading System

검색결과 264건 처리시간 0.031초

환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석 (Comparison of Performance Analysis of the Ventilated and Non-­ventilated CIGS BIPV Units)

  • 김상명;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.47-57
    • /
    • 2017
  • CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was $6.8^{\circ}C$ lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

온실의 자동단열시스템에 관한 연구 (Automatic Insulation System in Greenhouses)

  • 이석건
    • 한국농공학회지
    • /
    • 제29권4호
    • /
    • pp.117-123
    • /
    • 1987
  • This study was conducted to develop an automatic insulation system to reduce the heat loss through the wall of greenhouses during the nighttime in winter. A double covered model vinyl house was constructed, and blowers were used to fill or remove styrene pellets automatically the inside of the double-wall of the double covered vinyl house. The effects of insulation of the double covered vinyl house insulated with the styrene pellets were analyzed by comparing with the single covered vinyl house. The results obtained from this study can be summarized as follows : 1. The optimum thickness of the double-wall of the double covered vinyl house was found to be 5 to 10 cm. 2.When the outside temperature varied in the range of -8.3 to -1.5$^{\circ}C$ during the nighttime, the inside temperature of the double covered vinyl house insulated with the styrene pellets showed 7.7 to 11.7$^{\circ}C$ and the inside temperature of the single covered vinyl house showed -5.8 to 2.3$^{\circ}C$. Therefore, the effects of insulation of the double covered vinyl house insulated with the styrene pellets were confirmed to be excellent. 3. Also, the excessive increase of the inside temperature in the vinyl house was prevented by the shading effect of the double covered vinyl house insulated with the styrene pellets during the daytime. 4. When the outside temperature varied in the range of 17.7 to 30.0$^{\circ}C$ during the daytime, it was possible to keep the inside temperature at 30${\pm}$4$^{\circ}C$ in the double covered vinyl house by operating the insulation system. 5. The transmissivity of the double covered vinyl house with the styrene pellets removed was 52.4 % on the average.

  • PDF

IEEE 802.11 기반 저전력 위치 추적 장치의 설계 및 구현 (Design and implementation of low-power tracking device based on IEEE 802.11)

  • 손상현;김태욱;백윤주
    • 한국정보통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.466-474
    • /
    • 2014
  • 무선 네트워크 기술과 모바일 프로세서의 성능이 향상됨에 따라 스마트 폰과 같은 무선통신이 가능한 소형 단말이 널리 활용되고 있다. 이러한 이동형 장치는 GPS를 이용하여 위치정보의 활용이 가능하여 위치정보를 기반으로 하는 서비스가 증가하고 있다. GPS는 위성신호를 수신할 수 없는 실내와 전파음영지역에서 위치 정보를 제공하지 못하며, 근거리 통신기술을 이용하는 시스템은 인프라의 구축이 필수적이다. IEEE 802.11을 기반으로 하는 추적 시스템은 널리 보급된 AP 인프라를 기반으로 위치 측정이 가능하나 표준 동작을 따를 때 심각한 전력소모의 문제가 있다. 본 논문에서는 IEEE 802.11 기반 저전력 위치 추적 장치를 제안한다. 저전력 동작을 위해 채널 검색 및 연결유지로 인한 전력소모를 최소화하여 동작시간을 극대화 하였다. 성능평가를 위해 저전력 태그 장치를 설계 및 구현하여 전력소모를 측정하였으며, 시뮬레이션 결과 기본 방법에 비해 제안 방법의 전력소모가 46% 감소함을 확인하였다.

PC 기반의 3차원 의료영상 재구성 시스템의 고속화 설계 (Speed Optimization Design of 3D Medical Image Reconstruction System Based on PC)

  • 배수현;김선호;유선국
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.189-198
    • /
    • 1998
  • 3차원 의료영상 재구성 기법은 2차원 의료영상으로부터 인체의 복잡한 3차원 구조를 이해하는데 많은 도움을 준다. 본 논문에서 구현한 3차원 의료영상 재구성 시스템은 저가의 PC 기반에서 시스템의 환경에 상관없이 사용될 수 있도록 Visual C++4.2를 이용하여 작성하였으며 향후 확장성을 고려하여 각 기능을 모듈화 시켰다. 모듈 설계된 3차원 의료영상 재구성 시스템은 데이터 준비, 그래디언트 근시화, 분할, 음영처리, 좌표시스템 변환, 그리고 광선투사와 합성 모듈로 구성되었다. 본 논문에서는 3차원 의료영상 재구성 방법의 속도문제를 개선하여 저가의 PC 환경에서 구현하였다. PC 환경에서 3차원 의료영상 재구성 시스템을 구현하기 위하여 광선투사를 재구성되는 영상에 영향을 주지 않는 범위에서 조기 중단시키는 알고리듬과 영상 재구성에 참여하는 체적소를 줄이는 방법, 그리고 영상을 재구성하기 위한 광선투사 과정에서 투시되는 광선의 수를 줄이는 방법 등ㄹ을 적용하여 PC환경에서 3차원 의료영상 재구성 시스템의 고속화를 이루었으며 실험에 의해서 PC환경에서도 의료영상 재구성 알고리듬이 효과적으로 사용되었다.

  • PDF

Differential Power Processing System for the Capacitor Voltage Balancing of Cost-effective Photovoltaic Multi-level Inverters

  • Jeon, Young-Tae;Kim, Kyoung-Tak;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1037-1047
    • /
    • 2017
  • The Differential Power Processing (DPP) converter is a promising multi-module photovoltaic inverter architecture recently proposed for photovoltaic systems. In this paper, a DPP converter architecture, in which each PV-panel has its own DPP converter in shunt, performs distributed maximum power point tracking (DMPPT) control. It maintains a high energy conversion efficiency, even under partial shading conditions. The system architecture only deals with the power differences among the PV panels, which reduces the power capacity of the converters. Therefore, the DPP systems can easily overcome the conventional disadvantages of PCS such as centralized, string, and module integrated converter (MIC) topologies. Among the various types of the DPP systems, the feed-forward method has been selected for both its voltage balancing and power transfer to a modified H-bridge inverter that needs charge balancing of the input capacitors. The modified H-bridge multi-level inverter had some advantages such as a low part count and cost competitiveness when compared to conventional multi-level inverters. Therefore, it is frequently used in photovoltaic (PV) power conditioning system (PCS). However, its simplified switching network draws input current asymmetrically. Therefore, input capacitors in series suffer from a problem due to a charge imbalance. This paper validates the operating principle and feasibility of the proposed topology through the simulation and experimental results. They show that the input-capacitor voltages maintain the voltage balance with the PV MPPT control operating with a 140-W hardware prototype.

BIM을 활용한 컬러모듈 BIPV 건축 설계 최적화 방안 연구 - 서울 지역 실증 일사량 데이터 중심으로 - (A Study on the Optimization of Color Module BIPV Architectural Design Using BIM - Based on the data of Seoul surveyed solar radiation -)

  • 전현우;윤혜경;박서준
    • 한국BIM학회 논문집
    • /
    • 제9권3호
    • /
    • pp.19-29
    • /
    • 2019
  • Currently, BIPV (Building Integrated Photovoltaic) design technology lacks analysis function at the planning stage, and there is a lack of understanding and reliability of BIPV design method and system for building designers. To design and consider various building integrated solar design alternatives, the color of building integrated solar is often monotonous or does not match the design direction of the building. In this study, architectural designers can select various color modules in the planning and design process of the building and analyze the characteristics of color module solar cells and compare and analyze the actual solar radiation and predicted solar radiation in Republic ofKorea Seoul to reduce the confusion of design methods. By building a BIM design integrated system that can prove the quality of the building and analyze the shading analysis and power generation performance architecturally, it can improve the reliability of color module solar cell applicability that can express aesthetics in buildings and the predicted solar power generation capacity of each region. In the initial design stage, based on the empirical data of the BIPV system, it is possible to analyze the power generation performance for each installation angle and installation direction by analyzing the surrounding environment and the installation area, and accurately determine the appropriateness of the design accordingly.

연집제로구간에서 발생하는 음영현상을 줄이기 위한 기법에서 신호지연이 미치는 영향 연구 (A Study on the Effect of Signal Delay in Reduction Technique for Reducing Shading)

  • 한두희;이규진
    • 융합정보논문지
    • /
    • 제8권6호
    • /
    • pp.243-249
    • /
    • 2018
  • 본 논문에서는 가시광 통신시스템의 변조 방식과 각 변조 방식이 Dimming level에 미치는 영향을 분석하고, 지연신호로 인한 왜곡이 미치는 영향에 대해서 연구하였다. 현재 가시광 통신에서 가장 많이 사용되는 변조 방식들은 통신 성능은 증가하나 전체 조명의 밝기를 감소시키는 결과를 나타낸다. 연속적인 Burst Zero Duration이 발생하면 조명 기능이 심각하게 저하된다. 이는 조명뿐만 아니라 전체 시스템의 성능저하 시키게 되며 Flicker 현상을 유발한다. 본 논문에서는 이러한 변조 기술과 조명-통신 성능의 관계를 분석하고, 신호지연으로 인한 왜곡이 발생하였을 경우에 가시광 통신 시스템에 미치는 영향을 연구하였다. 시뮬레이션을 통해 통신-조명성능이 가장 좋은 IPI-OOK의 성능을 분석하고 그에 따른 향후 연구방향을 제안하였다.

2단 베드 시스템의 하단부에서 자란 딸기의 생산성 및 과일 품질에 미치는 보광 LED의 효과 (Effects of Supplemental LED Lighting on Productivity and Fruit Quality of Strawberry (Fragaria × ananassa Duch.) Grown on the Bottom Bed of the Two-Bed Bench System)

  • 최효길;정호정;최경이;최수현;채수천;안승원;강희경;강남준
    • 생물환경조절학회지
    • /
    • 제27권3호
    • /
    • pp.199-205
    • /
    • 2018
  • 본 연구의 목적은 2단 베드 벤치 시스템에서 딸기를 재배하는 동안 상단베드에 의한 차광으로 광량 부족한 하단 베드에서 자란 딸기의 생산량 및 과일 품질에 LED 보광의 영향을 확인하기 위한 것이다. 딸기 전용상토로 충진된 2단 베드 벤치에 2015년 10월부터 2016년 1월까지 점적 관수로 딸기를 재배하였다. LED 광이 처리되지 않은 상단과 하단 베드를 대조구로 이용하였고, LED 광 처리를 위해서 오전 10시부터 오후 4시까지 하단 베드에 각각 청색, 적색, 그리고 청색과 적색을 혼합한 LED 광을 $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$의 광량으로 보광 하였다. 딸기의 수확량에 있어서, 하단 베드의 청색 LED 보광된 처리에서 자란 딸기는 하단 부분 대조구와 비교하여 유의하게 증가되었으며, 상단 베드 대조구에서 자란 딸기 생산량의 90% 수준까지 증가되었다. 청색 및 혼합 LED와 상단베드에서 생육된 딸기 과일의 유리당 함량은 적색 LED와 하단 베드 부위 대조구에 비하여 높았다. 안토시아닌의 함량은 자연 광을 많이 받는 상단 베드에서 생육된 딸기 과일이 가장 높았지만, 하단베드 처리만을 비교하할 때, LED를 보광한 모든 딸기과일이 보광하지 않은 하단 부분의 대구조의 딸기 과일보다 높았다. 따라서 딸기 2단 베드 재배 시 하단 베드에 청색 LED 보광이 생산 증대 및 품질 향상에 유리할 것으로 판단된다.

인공광을 이용한 접목표 활착촉진 시스템의 시작품 설계 - 활착촉진 시스템 내의 기온과 상대습도 분포에 미치는 기류속도의 효과 (Design of a Prototype System for Graft-Taking Enhancement of Grafted Seedlings Using Artificial Lighting - Effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system)

  • 김용현
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.213-220
    • /
    • 2000
  • Grafting of fruit-bearing vegetables has been widely used to increase the resistance to soil-borne diseases, to increase the tolerance to low temperature or to soil salinity, to increase the plant vigor, and to extend the duration of economic harvest time. After grafting, it is important to control the environment around grafted seedlings for the robust joining of a scion and rootstock. Usually the shading materials and plastic films are used to keep the high relative humidity and low light intensity in greenhouse or tunnel. It is quite difficult to optimally control the environment for healing and acclimation of grafted seedlings under natural light. So the farmers or growers rely on their experience for the production of grafted seedling with high quality. If artificial light is used as a lighting source for graft-taking of grafted seedlings, the light intensity and photoperiod can be easily controlled. The purpose of this study was to develop a prototype system for the graft-taking enhancement of grafted seedlings using artificial lighting and to investigate the effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system. A prototype graft-taking system was consisted by polyurethane panels, air-conditioning unit, system controller and lighting unit. Three band fluorescent lamps (FL20SEX-D/18, Kumho Electric, Inc.) were used as a lighting source. Anemometer (Climomaster 6521, KANOMAX), T-type thermocouples and humidity sensors (CHS-UPS, TDK) were used to measure the air current speed, air temperature and relative humidity in a graft-taking system. In this system, air flow acted as a driving force for the diffusion of heat and water vapor. Air current speed, air temperature and relative humidity controlled by a programmable logic controller (UP750, Yokogawa Electric Co) and an inverter (MOSCON-G3, SAMSUNG) had an even distribution. Distribution of air temperature and relative humidity in a graft-taking enhancement system was fairly affected by air current speed. Air current speed higher than 0.1m/s was required to obtain the even distribution of environmental factors in this system. At low air current speed of 0.1m/s, the evapotranspiration rate of grafted seedlings would be suppressed and thus graft-taking would be enhanced. This system could be used to investigate the effects of air temperature, relative humidity, air current speed and light intensity on the evaportranspiration rate of grafted seedlings.

  • PDF

공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 - (An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements -)

  • 조정철;박재승
    • 한국실내디자인학회논문집
    • /
    • 제21권4호
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF