• Title/Summary/Keyword: Sewage water source

Search Result 176, Processing Time 0.024 seconds

Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin (영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구)

  • Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.

Domestic Sewage Treatment with a Successive System of Activated Sludge Process and Phytoplankton Cultivation

  • Hong, W.H.;Pack, M.Y.
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1978.10a
    • /
    • pp.209.1-209
    • /
    • 1978
  • Treatment of domestic sewage discharged from big cafeteria kitchen, especially rice-washing water, was examined by the use of activated sludge process and phytoplankton cultivation. Only with a activated sludge process COD value decreased from around 1000 mg/ι to 100 mg/ι, but nutrients, such as nitrogen and phosphate could not be removed sufficiently phytoplankton cultivation in combination with a activate sludge process could decrease COD value down to 50 mg/ι and nutrients values were also reduced substantially. However, the initial concentration of 20 mg/ι in the rice-washing water could not be removed completely without addition of activated sludge as a nitrogen source.

  • PDF

Groundwater Quality Characteristics of Pollution Concerned Area in Gyeongnam Using Groundwater Quality Monitoring Data (지하수수질측정망 자료를 활용한 경남 오염우려지역의 지하수 수질 특성)

  • Cha, Suyeon;Seo, Yang Gon
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.174-181
    • /
    • 2021
  • This study analyzed the groundwater quality characteristics according to the main source of pollution and quarter (season) by using data from the pollution exclusive monitoring network in the Gyeongsangnam-do area for five years (2013-2017). The main source of pollution was the industrial complex areas, waste mines, and sewage treatment facilities. The analysis items were field measurement items (water temperature, pH, electrical conductivity, dissolved oxygen, oxide reduction potential), positive ions, and negative ions. Water temperature and pH did not vary significantly according to the main source of pollution. In industrial complex areas, the value of electrical conductivity was the highest, and dissolved oxygen value was the lowest. The mean concentration of positive and negative ions was the largest in industrial complex areas, followed by sewage treatment facilities and waste mines. It was shown that the concentration of sodium ion was the highest in industrial complex areas and calcium ion in waste mines and sewage treatment facilities. The concentration of bicarbonate ion was the highest in all main sources of pollution. Water temperature, pH, and concentrations of cations and anions did not vary significantly from quarter to quarter. Of the water quality types, the Na-HCO3 type accounted for the highest proportion, but the Na-Cl type, which has a high possibility of external contamination, accounted for about 20% of the total data in the pollution exclusive monitoring network.

Characteristics of Low Calorific Value of Sewage Sludge by Drying Method (수직원통식 박막 건조방식에 의한 하수슬러지의 저위발열량 특성)

  • Mo, Jounggun;Lee, Kwangsung;Chung, Hanshik
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.55-62
    • /
    • 2017
  • In this study, the water content and the low calorific value of the dried sludge are analyzed by using a vertical cylinder type indirect heating type dryer for evaluatation of energy source value. The vertical cylindrical thin film dryer was an Okadora Pilot Plant, and the dryer was indirect heating vertical thin film type. The internal standard consisted of 500 mm in diameter and 700 mm in height. In the drying experiment, 10 kg of dehydrated sewage sludge was added to the dryer and the total amount of the sludge was adjusted to 27 times by variable of the time, the number of revolutions and the steam temperature. The results of analysis of the 27th experiment component of the dried product showed that the average low calorific value of about 11.2 MJ/kg and the water content of 6%. This is satisfy the fuel use standard of the thermal power plant of the sludge.

Feasibility Tests on Struvite Production from Liquid Fertilizer by Utilizing Ferronickel Slag and Sewage Sludge Ash (페로니켈슬래그와 하수슬러지소각재를 이용한 액비로부터 스트루바이트 생산 타당성 연구)

  • Kim, Hyeon;Kwon, Gyutae;Jahng, Deokjin
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.316-327
    • /
    • 2018
  • Liquid fertilizers made from livestock manure contain high concentrations of nitrogen and phosphorus and thus are used as a fertilizer. However, excessive use of liquid fertilizer causes eutrophication of agricultural land and nonpoint source pollution. In this study, as a means of lowering the nutrient concentrations, struvite ($MgNH_4PO_4{\cdot}6H_2O$) production from the liquid fertilizer was investigated. When liquid fertilizers produced in Gyeonggido were analyzed, its characteristics differed by region and season, but the phosphorus concentration was commonly lower than that of nitrogen. When $K_2HPO_4$ and $MgCl_2$ were added to the liquid fertilizers, the optimal pH for struvite formation was pH 9.5. For environmentally friendly sources of magnesium and phosphate, ferronickel slag (FNS) and sewage sludge ash (SSA) were suspended in deionized water and extracted by sulfuric acid with various mass ratios. The optimum conditions for extracting FNS and SSA were 4.0 M sulfuric acid and 0.35 mass ratio of sulfuric acid to sewage sludge ash, respectively. For forming struvite, 0.233 L of SSA leachate (SSAL) was added into 0.3 L of liquid fertilizer containing 2,586 mg/L of ammonia and 110 mg/L of phosphate, pH was then adjusted to pH 9.5 using 10 M of NaOH. Afterwards 0.333 L of FNS leachate (FNSL) was added to this mixed solution. After a reaction for 1 hr at room temperature, the remaining concentrations of magnesium, ammonium, and phosphate were less than 50 mg/L, 500 mg/L and 150 mg/L, respectively, and 30 g of precipitates were obtained, most of which were struvite.

Analysis of Influential Factors on Nitrate Distribution in Ground Water in an Urbanizing Area using GIS (도시화 지역에서 GIS를 이용한 지하수 질산성질소 분포 영향요인 분석)

  • Won J.S.;Woo N.C.;Kim Y.J.
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.647-655
    • /
    • 2004
  • To identify the influential factors and their relative significance on spatial distribution of $NO_3-N$ in urban ground water, spatial analysis was conducted using GIS and statistical approaches in the Seongnae-Koduk watersheds, where rapid urbanization has been proceeded. Several factors were considered including land-use type, distance to sewage lines, the ratio of impervious surface, and the ratio of green area. The spatial distribution of $NO_3-N$ in the land-use types shows differences between urban and crop field possibly due to the sewage networks in urban areas and the agrochemical uses in crop field. Nitrate concentrations in ground water were decreased with the distance to sewage lines to approximately 60-75 m. Concentrations of nitrate and distances to sewage lines showed negative correlation, indicating that the nitrate contamination was induced from the sewage system and specially significant in urban areas. The negative correlation of the ratio of impervious surface to the nitrate concentration in urban areas also suggested that the source materials of nitrate are introduced from the surface. Consequently, in areas of urbanization processes, systematic management of past-and-present land-use types and sewage systems are the most significant factors in preventing ground water from nitrate contamination.

The NPS Analysis and CSO Management Based on SWMM for Oncheon Basin (SWMM 모형을 이용한 비점오염 분석 및 CSO 관리방안 연구 - 부산시 온천천 유역 대상 -)

  • Shin, Hyun Suk;Son, Jeong Hwa;Jang, Jong Kyung;Shon, Tae Seok;Kang, Dookee;Cho, Dukjoon
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.268-280
    • /
    • 2009
  • Oncheon basin which are located in Busan is divided into 43 basin on the basis of main pipe, constructed with Storm Water Management Model (SWMM). Occurrence situation for Outflow and pollutant loads by long-term continuous rainfall is examined for treatment district and river analysis point of Oncheon basin and a reduction vs effectiveness table for effective CSOs managements is made for each of treatment districts according to each of managements. In case that treatment equipment is located at the discharge point of CSO, treatment efficiency is analysed. It is supposed that treatment equipment have an efficiency on the basis of a concentration and runoff discharge over a critical flow is discharged with it untreated and treating runoff discharge with treatment equipment at each of runoff discharge points and treating it gathered at sewage treatment plant (STP) through trunk sewer is compared for a relative treatment efficiency.

Change in Agricultural Irrigation Water Quality in Mankyeong River (만경강 수계 농업용수의 시기별 수질변화)

  • Lee, Kyeong-Bo;Lee, Deog-Bae;Lee, Sang-Bok;Kim, Jae-Duk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.6-7
    • /
    • 1999
  • The water quality at Mankyeong River was surveyed 13 sites of main stream for 6 months from April to September in 1995 and 1997. The monthly average value of $NH_4-N$, $SO_4^{2-}$ and $Cl^-$ showed the highest peak in April while that of $NO_3-N$ showed the highest peak in August. The monthly average value of COD showed the highest peak in September at high temperature season. Concentrations of $NH_4-N$ and $SO_4^{2-}$ in Mankyeong River stream exceeded the standard water quality criteria in many sites. The water quality of Mankyeong River stream was not suitable for the irrigation source excepted the sites such as Hari, Gosan stream and Soyang stream. The floodgate of Mokcheon, Yocheon, Jeonju and Samcheon stream were rapidly polluted by the sewage of city, otherwise the Iksan stream was rapidly polluted by the sewage of swine. The sum of ionic concentrations in Mankyeong River stream was the highest at floodgate of Yocheon by influence of the sewage from city and industry. The order of the major anions and cations concentration in Mankyeong River stream were $SO_4^{2-}$ > $Cl^-$ > $NO_3-N$ > $SO_4^{3-}$ and $Na^+$ > $Ca^{2+}$ > $NH_4^+$ > $Mg^{2+}$ > $K^+$, respectively.

  • PDF

Database and User Interface for Pollutant Source and Load Management of Yeungsan Estuarine Lake Watershed Using GIS (GIS를 활용한 영산호 수계 오염원 데이터베이스 구축과 오염원관리 사용자 인터페이스)

  • 양홍모
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.6
    • /
    • pp.114-126
    • /
    • 2001
  • The purpose of this study is to establish the databases of pollutant sources and water quality measurement data by utilizing GIS, and making the user interface for the management of pollutant sources. Yeongsan Estuarine Lake was formed of a huge levee of 4.35 km constructed by an agricultural reclamation project. Water quality of the reservoir has been degraded gradually, which mainly attributes to increase of point and non-point source pollutant loads from the lake's watershed of 33,374.3 $\textrm{km}^2$ into it. Application of GIS to establishment of the database was researched of pint source such as domestic sewage, industrial wastewater, farm wastes, and fishery wastes, and non-pont source such as residence, rice and upland field, and forest runoffs of the watershed of the lake. NT Acr/Info and ArcView were mainly utilized for the database formation. Land use of the watershed using LANDSAT image data was analyzed for non-point source pollutant load estimation. Pollutant loads from the watershed into the reservoir were calculated using the GIS database and BOD, TN, TP load units of point and non-point sources. Total BOD, TN, TP loads into it reached approximately to 141, 715, 2,094 and 4,743 kg/day respectively. The loads can be used as input parameters for water quality predicting model of it. A user-friendly interface program was developed using Dialog Designer and Avenue Script of AcrView, which can perform spatial analysis of point and non-point sources, calculate pollutant inputs from the sources, update attribute data of them, delete and add point sources, identify locations and volumes of water treatment facilities, and examine water quality data of water sampling points.

  • PDF

The improvement of the operating process of sewage treatment plants in the upstream area of dam by MASS FLOWmodelling (MASS FLOW 모델링을 통한 댐상류지역의 공공하수처리시설 공정개선방안)

  • Lee, Hyunseop;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.130-138
    • /
    • 2020
  • As of 2017, the sewerage penetration rate of Seoul and metropolitan cities is more than 90%, and the number of domestic sewage treatment plants increased by 25% from 3,064 in 2010 to 4,072 in 2017. Among them, sewage treatment plant operated by SBR system is 585, which is 17% higher than 2010. In order to improve the water quality of the water source and improve the operation of the small sewage facilities, the improvement of the process was studied by applying the modelling to 49 facilities of the sewage treatment plant in Andong Imha dam area with more than 500㎥/day 3 places and 46 places less than 500㎥/day. As an improvement plan for modelling, candidate data were derived by reviewing operation data for 5 years. 49 facilities are operated by 12 types of operating processes. Among them, 1 place mort than 500㎥/day with SBR method and 9 facilities with less than 500㎥/day were selected by dividing 46 sites into 3 types. As a result of applying modelling to more than 500㎥/day, it was possible to improve the quality of discharged water through SRT control and it was found that applying model to sites of small scale treatment plants can improve the removal efficiency of TP by up to 14.4%. As a result, the data of this study could be used to improve and improve the operation of sewage treatment plants and RCSTP(Rural Community Sewage Tratment Plant).