• 제목/요약/키워드: Sewage water source

검색결과 176건 처리시간 0.028초

Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구 (A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy)

  • 황용하
    • 융복합기술연구소 논문집
    • /
    • 제1권2호
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF

공공하수처리시설의 총인기준 강화에 따른 비용효과분석 (Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities)

  • 정원구;임재명
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

하수열원 열펌프 시스템의 성능 시뮬레이션 (A Characteristics Simulation of Heat Pump System for Sewage Water as a Heat Source)

  • 박일환;장기창;이영수;윤형기;백영진
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.280-286
    • /
    • 2008
  • In this study, characteristics simulation of heat pump system is investigated for heating and cooling using sewage water as a heat source. A simulation program for preestimate operation characteristics of heat pump system is developed. The performance of this system is resolved by several variables and the characteristics which is based on actual air and sewage temperature data. The simulation results agree well with the experimental values of COP. In the analysis of system characteristics, the COP is changed between $3\sim5$ in winter season for heating load, $4\sim6$ in summer season for cooling load. As the results of Life Cycle Cost analysis over a 15 year life cycle, the energy cost could be reduced by 250 million won if a heat pump system was used instead of a conventional boiler and an absorbtion refrigerator on the office building.

마산만의 하수기인 유기물 fecal sterol의 분포 (Distribution of sewage-derived organic matter using fecal sterol in Masan Bay, Korea)

  • 최민규;문효방;김상수;이윤
    • 한국환경과학회지
    • /
    • 제14권5호
    • /
    • pp.481-490
    • /
    • 2005
  • Surface sediments and seawater were sampled at Masan and Haengam Bays of Korea, to evaluate contamination by sewage-derived organic matter using fecal sterols, Six stream-water samples into Masan and Haengam Bays were also sampled. Total concentrations of eight sterols (coprostanol, epichloestanol, epicoprostanol, cholesterol, cholestanol, brassicasterol, stigmasterol and $\beta-sitosterol$) were in the range of $1,274\~4,768{\mu}g/g$ dry weight in suspended particulate from the stream-water, $292\~2,244{\mu}g/g$ dry weight in suspended particulate from the seawater and $4.5\~27.2{\mu}g/g$ dry weight in the sediments. Although sterol compositions in sediments, seawater and stream-water were different, cholesterol was the predominant sterol in all samples. The proportion and concentration of coprostanol, a sewage tracer, in stream-water was much higher than those in sediment and seawater. The sterol levels including coprostanol in the sediments and seawater were higher at inner basin than at the outer bay. Some molecular indices and multivariate statistical analysis were used to assess the origin of these sterols and sewage contamination in the study area. The sterol composition patterns in stream-water were mainly associated with contamination by sewage-derived organic matters and those of seawater were associated with the activities of marine-originated organisms. Sterol levels in the sediments were both from the sewage input through stream-water and the marine- originated organisms. This survey suggests that the main source/route of sewage-derived organic matters in Masan Bay is the input of stream-water into the bay.

제주도내 유수하천에 대한 수질특성 및 오염부하량 산정 (The Characteristics of Water Quality and the Estimation of Pollutant Loadings from the Flowing Streams in Cheju Island)

  • 조은일;오윤근
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.845-851
    • /
    • 1998
  • In order to manage the water quality from the flowing streams in Cheju Island, the characteristics of water quality was investigated from August, 1996 to May, 1997 and the pollutant loadings for future were estimated from the watershed at each stream. Comparing the mean concentrations of each water quality with the criterion of water quality in river, it was under I class except for Changgo Stream, for DO, under I class at the whole station for SS and under II class for BOD. As the pollutant loadings at each stream in 2020 is compared with those in 1996, the estimated results are as follows : 1) for BOD, 59% at Donghong Stream, 24% at Yeonoe Stream, 44% at Ohngpo Stream and 57% at Changgo Stream. 2) for T-N, 91% at Donghong Stream, 76% at Yeonoe Stream, 63% at Ohngpo Stream and 89% at Changgo Stream. 3) for T-P, 69% at Donghong Stream, 42% at Yeonoe Stream, 45% at Ohngpo Stream and 73% at Changgo Stream. The point source loadings discharged through combined sewer could be treated at sewage treatment plant. However, the expected slow decreasing rate of BOD, T-N, and T-P loadings is due to the part of untreated nonpoint source loadings. Nonpoint source loading overflow typically occurs when the flow of stormwater combined with sewage exceeds the capacity of the interceptor sewers. Since most of the sewers used in Cheju Island are the combined sewers, the combined overflow sewage is bypassed into the receiving water area after a rainstorm. Therefore, a means to control nonpoint source loadings should be considered for the river and marine water quality management.

  • PDF

낙동강 유역 내 하수처리구역의 비점 배출 부하량 분석 (Analysis on Load of Non-point Source from Sewage Treatment Districts in Nakdong River)

  • 신현석;김미은;김재문;장종경
    • 한국수자원학회논문집
    • /
    • 제48권9호
    • /
    • pp.695-709
    • /
    • 2015
  • 지속적인 개발과 도시화로 인하여 하천으로 유입되는 비점오염원의 비율 역시 점차 증가하는 추세이며 비점오염원이 수질악화에 미치는 영향은 점점 더 커지고 있다. 하천의 수질오염을 발생시키는 비점오염원 해결방안을 모색하고 있지만 도시화에 따른 수문현상변동 및 자연현상과 관련된 문제라 연구에 어려움이 많다. 본 연구에서는 기존의 총량원단위법과 달리 유역의강우 및 도시화 특성과 처리장 운영자료를 활용하여 차별화된 비점오염원 산정 방법을 제시하였다. 하수처리장의 배수구역 내 관거시스템을 합류식으로 가정하여 강우 시 하수처리장의 배수구역별 비점 발생형태는 하수처리장 강우유 입량, 하수처리장 우회유량(bypass) 및 하천토구의 CSO의 3가지로 크게 구분하여 적용함으로써 오염부하량을 산정함으로써 오염총량 단위유역 및 하수처리구역의 관리를 위한 비교자료로 활용 가능할 것으로 판단된다.

동절기 마을하수처리장 영양염류 제거에 관한 연구 (A Study of RCSTP Nutrient Removal Efficiency in Winter Season)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제16권3호
    • /
    • pp.363-370
    • /
    • 2014
  • 농촌 지역 마을하수도 보급률은 도시 지역에 비해 38% 정도 수준밖에 되지 않는다. 농촌 지역은 상수원 인근에 위치하여 농촌지역에서 발생하는 하수는 상수원 오염의 원인으로 알려져 있다. 그래서 정부에서는 마을하수도 관리에 많은 노력을 기울이고 있다. 본 연구에서는 동절기 마을하수도 영양염류 제거 효율을 분석하였으며, 안동 임하댐 인근에 위치한 봉화, 영양 그리고 안동의 신설된 마을하수도를 연구 대상으로 선정하였다. 동절기 마을하수도 영양염류 제거 효율은 체류 시간과 미생물 농도에 영향을 받는 것으로 나타났다. 따라서 마을하수도 운전 시 영양염류 처리를 위해 운전 조건 조절 및 유지관리가 필요하다는 것을 의미한다.

Reuse of Reclaimed Water for Irrigation on Paddy Rice Culture and Its Effect

  • Chun G. Yoon;Ham, Jong-Hwa;Jeon, Ji-Hong
    • 한국농공학회지
    • /
    • 제44권7호
    • /
    • pp.14-24
    • /
    • 2002
  • The effect of reclaimed water irrigation on paddy rice culture was evaluated by pilot study at the experimental field of Konkuk University in Seoul, Korea. The sewage was treated by constructed wetland system, and its effluent was used as irrigation water for four treatments and one control plots with three replications. Irrigation of reclaimed water onto paddy rice cultures did not adversely affect the growth and yield of rice. Instead, experimental rice plots of reclaimed water irrigation displayed about 10 to 50% more yield on average than controls. This implies that reclaimed water irrigation might be beneficial rather than harmful to rice culture as long as the sewage is treated adequately and used properly. The amount of irrigation water had little effect on experimental rice cultures, but its strength was important. The strength of treated sewage was not a limiting factor in this study, and no lodging was observed even with a relatively high nitrogen concentration (up to 160mg/L). In general the paddy soil was not affected by reclaimed water irrigation. However, there was an indication that continuous irrigation with high strength of reclaimed water might cause salt accumulation in the soil. Supplemental use of reclaimed water with existing sources of irrigation water is recommended rather than irrigation with a single source of reclaimed water. Overall, the results demonstrated that reclaimed water could be reused as a supplemental source of irrigation water for paddy rice culture without causing adverse effects as long as it is properly managed. For full-scale application, further investigation should be done on environmental risks, tolerable water quality, and fraction of supplemental irrigation.

Source identification and Pathway analysis of Nitrate contamintation in "Cultural village", Jeungpyeong

  • 전성천;이강근;배광옥;정형재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.254-257
    • /
    • 2002
  • The purposes of this research are to identify the source and to analyze the pathway of nitrate contamination in "cultural village", Jeungpyeong. In order to examine recharge processes and flow pattern that closely related to the influent of nitrate contaminant, the flow field was simulated and the oxygen and hydrogen stable isotopes were analyzed. The nitrogen isotope was used to delineate contaminant sources. The shallow groundwater was mainly composed of precipitation, but leakage of domestic water and sewage contributed to the recharge. Nitrate contaminants were possibly from the leakage of sewage and animal waste. The nitrate concentration decreased due to dilution by low concentration water.ion water.

  • PDF