• Title/Summary/Keyword: Sewage treatment system

Search Result 372, Processing Time 0.025 seconds

부패조와 모래트렌치를 이용한 소규모 오수 처리 (Small Sewage Treatment Using Septic Tank and Sand Trench)

  • 박영식
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.28-33
    • /
    • 2003
  • This study was carried out to treat sewage using sand trench combined with septic tank process in rural areas. In order to find optimum parameters, design and operation mode was changed from Run 1 to Run 4. In order to facilitate nitrification and T-P removal, diffuser and iron plate was installed in the 3rd trench of Run 2 period. The septic tank played a role as pre-application process of sand trench system. The removal efficiencies of COD, NH$_4$-N, T-P at steady state were 94.6%, 87.9% and 54.5%, respectively. Addition of diffuser and iron plate in the 3rd trench has increased the removal efficiencies of the NIL-N and T-P. In this system, denitrification were not occurred because of the high DO.

하수처리수의 하천유지용수 활용을 위한 역순환시스템의 비교 (The Inverse Circulation System for Using Treated Waste Water as Instream Flow)

  • 김기형;최계운;안태진;김진홍;심명필
    • 한국수자원학회논문집
    • /
    • 제36권5호
    • /
    • pp.863-878
    • /
    • 2003
  • 본 연구에서는 하천의 유지용수를 확보하기 위하여 하수처리장에서 처리하여 방류하는 하수처리수를 활용하기 위한 방안을 검토하고 이를 하천유지용수로 직접 활용하기 위하여 역순환시스템의 활용을 검토하였다. 역순환시스템은 하천 하류에 위치한 하수처리장으로부터 방류되는 하수처리수를 펌핑하여 하천상류부로 이송함으로써 하천에 부족한 유지유량을 확보하는 방법으로 여러 가지 형태의 이송방안을 조합하여 하천의 특성에 맞는 최적의 시스템을 구성하고 간단한 수처리를 적용함으로서 하수처리수의 수질을 추가적으로 개선할 수 있는 특징이 있다. 또한 이송된 하수처리수를 하천에 유입시키는 방안들은 시각적으로 친수적인 경관을 제공하고 폭기 등에 의한 수질개선효과를 얻을 수 있다. 이러한 하수처리수를 활용한 역순환시스템을 하천유지용수확보에 적용하기 위하여 국내 하수처리장의 처리수 활용실태 및 수질 상태 등을 검토하였고, 국내의 하수처리수 활용 사례를 조사하였으며 외국의 유사사례 조사를 통해 국내에 적용하기 위한 방안을 마련하고 실제 하천을 대상으로 역순환시스템의 적용방안을 제시하였다.

재사용을 위한 하수처리장 방류수의 고급산화처리 (Advanced Oxidation Processes of Secondary Effluent for Reuse)

  • 조일형;송경석;성기석;정문호;이홍근;조경덕
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.61-68
    • /
    • 2000
  • The use of photo-catalytic processes in pollution abatement and resource has a significant economic importance. Therefore, the applications of photochemical oxidation of secondary effluent driven by UV, TiO2, TiO2/UV, H2O2/UV and TiO2/H2O2/UV, have been investigated in order to treat the secondary effluent from municipal sewage. Various experimental parameters such as BOD, CODcr, Nurbidity, total P, and SPC were examined in each photo-catalytic reaction system. The results showed that the application of single oxidant such as UV, TiO2 only has a minor effect on parameters reduction (CODcr, BOD, etc) to treat the secondary effluent, whereas the combinations of oxidants increase the removal efficiency. The best removal efficiency in every parameters was achieved by the combination of TiO2, H2O2 and UV. It was also found that the optimum amount of TiO2 for the treatment was 1g/ι to achieve water reuse standard. From the results, the photocatalytic reaction system can be an alternative as a post-treatment to treat the secondary effluent from municipal sewage.

  • PDF

슬러지 멀티미터를 위한 근거리무선네트워크 데이터구조 설계 연구 (Study on Local Wireless Network Data Structure for Sludge Multimeter)

  • 정순호;김영기;이시진;이성화;박태준;변두균;차재상
    • 한국위성정보통신학회논문지
    • /
    • 제9권2호
    • /
    • pp.96-100
    • /
    • 2014
  • 최근 전 세계적으로 운영되는 하 폐수 처리시설 관리에 있어 환경 보호를 위한 엄격한 규제로 수질오염 측정 시스템에 관한 시스템이 부각되고 있으며, 대형시설 또는 산업단지 내의 자체 하수처리장이 건립되면서 하수처리장의 효율성 및 자동차에 대한 연구 및 개발이 활성화되고 있다. 하지만 기존 하수처리 시스템은 하 폐수에 특화된 수질감시 기술 및 이를 실시간 전송하기 위한 신뢰성 있는 네트워크 구축이 미흡한 실정이다. 따라서, 본 논문은 하수처리시설에서 슬러지의 농도를 효과적으로 측정 가능한 슬러지 멀티메터의 데이터를 수집하고 멀티메터를 제어하기 위한 근거리 무선 네트워크의 데이터 구조 설계를 제안하였다. 근거리 무선 네트워크를 통해 수집된 데이터는 중앙 모니터링 시스템으로 전달되어 실시간으로 데이터를 누적하고 통계를 산출하여 하수 처리 시설의 상태를 모니터링이 가능하다. 제안된 시스템은 근거리 무선 네트워크 시스템으로 IEEE 802.15.4와 비콘(Beacon)을 사용하여, 중앙시스템에서 실시간 상태 확인이 가능하도록 IEEE 802.11네트워크를 구성하였으며, 하수처리시설에 슬러지 멀티 메터를 설치하고 통신 네트워크를 구축해서 그 효율성을 입증함으로써 제안 기술의 유용성을 확인하였다.

DNR 시스템에 의한 하수(下水)의 고도처리(高度處理)에 관한 연구(硏究) (A Study on Advanced Municipal Wastewater Treatement by Daewoo Nutrients Removal (DNR) System)

  • 박명균;장윤석;박철휘;박칠림
    • 상하수도학회지
    • /
    • 제9권4호
    • /
    • pp.115-123
    • /
    • 1995
  • The purpose of this study is to investigate the characteristics and performance of nitrogen and phosphorus removal system, Daewoo Nutrients Removal(DNR) system, and to find out the operating parameter for the system. During the study, $10m^3$ pilot plant was operated for the demonstration experiment and the primary effluent was taken from K domestic sewage treatment plant. The TN in the influent had been removed to approximately 70% through the nitrfication in the oxic tank and the denitrfication in the anoxic tank and the $PO_4-P$ and TP in the influent had been removed to 85% and 83% through anaerobic reaction and oxic reaction. The BOD and SS removal rate were 85 to 95% through the system. As the results, the values of effluent BOD, SS and slouble phosphorus were lower than A/O and $A^2/O$ processes. The SPRR (specific phosphorus release rate) at the anaerobic state of DNR system was ranged from 2.2 to 2.6mg SP/g VSS/h. The nutrient removal efficieny of the DNR system in view of the characteristics of the domestic sewage was higher than the pre-established A/O and $A^2/O$ processes. Finally, we believe that the DNR system was superior to the processes deveolped recently.

  • PDF

Life Cycle Assessment(LCA)를 도입(導入)한 오니처리(汚泥處理)시스템의 평가(評價) (Life Cycle Assessment (LCA) on Sludge Treatment System)

  • 황용우;권봉기;유성호
    • 상하수도학회지
    • /
    • 제11권2호
    • /
    • pp.50-64
    • /
    • 1997
  • Life cycle assessment (LCA) on total sewage sludge treatment system from thickening to incineration and melting was performed for estimating global environmental impact as $CO_2$. In general, the life cycles of actual treatment facilities consist of construction, operation and dismantlement. In this study, the amount of $CO_2$ produced from both whole and each life cycle step of currently used unit sludge treatment processes were calculated by inventory analysis. In addition, in the all processes investigated in this study, individual $CO_2$ production unit (CPU), i.e. total produced $CO_2$ by treating a unit weight of sludge was also calculated. By using the CPU matrix of the unit processes, it was possible to simulate the $CO_2$ production for any type of complex-system as well as to trace a dominant cause of $CO_2$ production in each process. Four selected alternatives examined here, each involve the same disposal way but differ substantially in the $CO_2$ exhaust.

  • PDF

분사배출 고도 응집.생물여과 공정을 이용한 하수처리수 중의 TP 및 NOM 제거 (Removal of Phosphorus and NOM in Wastewater Effluent Using Ejector.BAF System)

  • 장영호;강동한;김극태;임흥빈;황찬원;김미정;신형순
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.505-511
    • /
    • 2012
  • While the existing sewage treatment facilities are mainly being operated by biological processes, winter-time efficiency improvement and additional phosphorus treatment equipment using chemicals have been required to follow the effluent criteria of TP (0.2, 0.3 and 0.5 mg/L for the zone of I, II and III respectively) and $BOD_5$ (5.0 mg/L) which is intensified from 2012 in Republic of Korea. We made an investigation into actual condition of biological treatment process and calculated the optimal chemical input amount by jar test of supernatant of secondary sedimentation tank to evaluate the process improvement for the intensified criteria. Ejector BAF system for removing TP, $BOD_5$ of sewage effluent was suggested. The concentration of TP from biological process is 0.3-0.8 mg/L, and the input amount of optimal chemical coagulant was above Al/P ratio of 3(1.9 mg/L as Al) to meet the criteria of TP for secondary treatment effluent. From the results of this experiment, the best Al/P ratio for Ejector BAF system was about Al/P ratio of 1, and LV of BAF process for intensified criteria of $BOD_5$ and TP was below 1.97m/hr.

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;JEONG, Tae-Hwan;Kim, Su-Hye;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권4호
    • /
    • pp.51-56
    • /
    • 2022
  • Purpose: By applying an ultrasonic mechanical device to the liquid fertilizer storage in the pig dropping treatment plant, the initial odor of the odor source is reduced, and the air dilution drainage of the complex odor is fundamentally recognized to facilitate odor treatment on the mechanical and chemical biological treatment devices at the rear. Research design, data and methodology: The odor concentration on the site boundary was measured to confirm the state of reduction. In order to prevent the spread of odor from the collection of the pig dropping treatment plant, it was measured by installing an ultrasonic generator inside the installation wall after installing the sealing wall. Results: The average value of the March and April measurement data remained close to neutral at 8.2 after 8.6 treatment before pH treatment, decreased 97.3% from 462 mg/L before SS treatment to 10.5 mg/L after treatment, and the composite odor was reduced by 85% from 20 to 3 before treatment. It was confirmed that ammonia (NH3) was reduced by 99% from 5.8 ppm to 0.09 ppm, and general bacteria were also reduced by 99% from 3,200 CFU/mL to 57 CFU/mL Conclusion: Applying the ultrasonic air ejector hybrid system and zigzag air complex module development product to resource circulation centers or sewage treatment facilities is thought to reduce inconvenience to residents due to odors caused.

막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리 (Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제24권1호
    • /
    • pp.20-30
    • /
    • 2014
  • C/N 비가 낮은 농촌마을 하수의 고도처리를 위하여 $0.4{\mu}m$의 세공크기를 갖고 있는 평막이 침지된 연속회분식 반응기를 사용하였다. 분말활성탄의 투입, 폭기량 및 유입 유기물 농도가 처리효율과 여과 성능에 미치는 영향을 조사하였다. 54일 이내의 조업 초기에서는 C/N 비가 증가할수록 COD, T-N 및 T-P의 제거율과 MLSS 농도는 증가하였다. 조업 89일 후의 COD, T-N 및 T-P의 제거율은 각각 97.1%, 75.0% 및 48.3%이었다. 막여과에 의해 처리수에서 SS는 검출되지 않았으며, T-P의 제거율이 낮게 나온 이유는 과잉의 슬러지를 배출하지 않았기 때문이다. 분말활성탄을 투여한 경우 조업이 진행됨에 따라 분말활성탄의 혼합강도와 충돌빈도가 증가하여 슬러지의 입자크기가 감소하였으며, 이로 인해 분말활성탄을 투여하지 않은 경우에 비해 TMP 상승이 크게 나타났다.