• Title/Summary/Keyword: Sewage plant

Search Result 637, Processing Time 0.025 seconds

Radioactive iodine analysis in environmental samples around nuclear facilities and sewage treatment plants

  • Lee, UkJae;Kim, Min Ji;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1355-1363
    • /
    • 2018
  • Many radionuclides exist in normal environment and artificial radionuclides also can be detected. The radionuclides ($^{131}I$) are widely used for labeling compounds and radiation therapy. In Korea, the radionuclide ($^{131}I$) is produced at the Radioisotope Production Facility (RIPF) at the Korea Atomic Energy Research Institute in Daejeon. The residents around the RIPF assume that $^{131}I$ detected in environmental samples is produced from RIPF. To ensure the safety of the residents, the radioactive concentration of $^{131}I$ near the RIPF was investigated by monitoring environmental samples along the Gap River. The selected geographical places are near the nuclear installation, another possible location for $^{131}I$ detection, and downstream of the Gap River. The first selected places are the "front gate of KAERI", and the "Donghwa bridge". The second selected place is the sewage treatment plant. Therefore, the Wonchon bridge is selected for the upstream of the plant and the sewage treatment plant is selected for the downstream of the plant. The last selected places are the downstream where the two paths converged, which is Yongshin bridge (in front of the cogeneration plant). In these places, environmental samples, including sediment, fish, surface water, and aquatic plants, were collected. In this study, the radioactive iodine ($^{131}I$) detection along the Gap River will be investigated.

A Survey on Operating State of ISWTP according to Building Use Type (건물용도에 따른 개별오수처리시설의 운영실태에 관한 연구)

  • Gwon, Eun-Mi;Kim, Jong-Seok;Chung, Wook-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.337-341
    • /
    • 2005
  • It is difficult to use average sewage water quality as a design parameter for the individual sewage wastewater treatment plant(ISWTP), because sewage water quality is very various according to the building use type. So, in this study, we estimated daily, seasonal and weekly trend of sewage water quality and flow rate in various kind of building to comprehend operating state of ISWTP. The sewage water quality and flow rate were higher in the business building than household building. The seasonal difference of the water quality was not detected but that of flow rate was high. The flow rate of the sewage in the business building was higher in summer than in other seasons and in weekend than in weekday. The treatment efficiency of IWSTP was about $70{\sim}80%$ with BOD, $40{\sim}50%$ with TN and TP, which was very low. The unit loads of the individual house were 36.05 gpcd with BOD, 37.91 gpcd with SS, 23.91 gpcd with T-N, and 7.90 gpcd with T-P respectively, and those values were higher than other studies. It is because, as distinct from other studies, sewage water quality was monitored at the inlet point of the IWSTP in this study. We can use this results as an one of basic parameters for the design of IWSTP.

Optimization of Operating Conditions for Each Linked Treatment Scenario using Sewage Treatment Modeling (하수처리 모델링을 이용한 연계처리 시나리오별 운전조건 최적화)

  • Kim, Sungji;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • Due to rapid industrial development, population growth, and improvement of living standards, the amount of sewage and wastewater, including nutrients, is increasing every year. In addition to the increasing amount of sewage and wastewater generation, untreated linked treated water (manure, livestock manure, industrial wastewater, leachate, food waste) is also increasing, and many of the linked treated water flows directly into nearby sewage treatment plants. The associated treated water causes many problems because of its own characteristics, low flow rate with high concentration compared to existing inflow sewage. In order to solve this problem, it is necessary to investigate the quantity and quality of the connected treated water whichh is flowed into the sewage treatment plant, and a study the effect on sewage treatment. Therefore, in this paper, we would like to examine the effect of the linked treated water. Seasonal effect associated with water pollution conditions was considered. In addition, a scenario was created through the distribution and inflow of connected treated water along with the water temperature conditions. Through scenario analysis, we intend to optimize the operating conditions of linked processing.

The Effect of Sewer Pipe Retrofit on The Operation of Sewage Treatment Plant in Rural Area (농촌 지역의 하수관거 정비사업이 하수처리장 운영에 미치는 영향)

  • Kim, Seongjung;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • Recently, rural areas are rapidly developing, while existing infrastructure is inadequate and aging compared to developing rural areas. The most representative of these is the sewer system. Therefore, in this study, the rural area of Gyeonggi A city was selected as the study area and analyzed the effect of the sewer maintenance business on the operation of the sewage treatment plant. The analysis items were pollutant treatment efficiencies, the changes of inflow sewage amount, sewage concentration, influnet load, and C / N ratio by comparing before and after the development. As a result of the analysis, the sewage amount increased significantly after the development, and the sewage concentration increased after the development and the load of the sewage in the wastewater treatment plant also increased after the development. And improvement and management of inflow of unidentified water such as infiltration water and influent water in the sewage pipe was improved due to improvement of sewage pipe, which is considered to have affected the increase of C / N ratio and the improvement of TN and TP removal efficiency. The results of this study can be used as a representative example of the sewerage maintenance project in the rural area that positively influenced the operation of the sewage.

Evaluation of Defect Types for Characteristic Database Construction of Large Sewage Box Culverts (대형 하수박스암거의 속성 데이터베이스 구축을 위한 결함유형 평가)

  • Han, Sangjong;Song, Homyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.619-628
    • /
    • 2017
  • As the 3D laser scanning technology capable of databaseing large sewage box culverts becomes possible, it is necessary to develop a standardization manual that can clearly distinguish the structural and operational defect types of box culver and analyze the defect data. In this study, we collected and analyzed defects in sewage box culverts of 14,827m in total by selecting three districts in Korea. The major defects were surface damages, and their defect densities were $2.17m^2/m$, $0.27m^2/m$ and $0.10m^2/m$ for aggregate exposure, Steel reinforcement exposure, and Steel reinforcement projecting. In order to support the decision of the box culverment management, it was divided into five grades and each defect code and defect score were allocated. The results of this study are useful for the diagnosis of the sewage box culverts in Korea and it is expected to support a decision making for management.

Development of an Environmentally Friendly Sewage Disposal Model for Agricultural and Fishing Village Areas (자연친화형 농어촌 하수처리장 모델개발)

  • Chung, Dong-Yang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.2 no.1
    • /
    • pp.10-19
    • /
    • 1999
  • In 1991, the ministry of Gov't. Administration and Home Affairs set up a minimum of one sewage disposal plant in each province. By 1995, 264 models of the capillary infiltration method were set up in 331(78%) villages and the contact oxidation method was set up in 52 places. Since the Gov't. sent a letter to each responsible officer across the country stating their disapproval of the capillary infiltration method, the environmentally friendly sewage disposal system has not been diffused. The current model(mechanical sewage disposal) being used, in agricultural and fishing villages, costs too much for maintenance and operation(\50,000 per capita per year). In particular, because of the difference in sewage characteristics of agricultural and fishing villages from urban sewage, the efficiency of the disposal system is very low. Also, because of the growing need for more disposal plants, the Gov't. is looking for cheaper alternatives. This study has analyzed 2 kinds of sewage disposal. The first is used widely in agricultural and fishing villages in Germany. The second is used widely in similar areas of Korea. It has intended to analyze the characteristics, merits and defects of the sewage disposal water plants and pebbles model which is used widely in Germany and developed compatibly for Korea.

  • PDF

Effects of Pre-aeration on the Anaerobic Digestion of Sewage Sludge

  • Ahn, Young-Mi;Wi, Jun;Park, Jin-Kyu;Higuchi, Sotaro;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.59-66
    • /
    • 2014
  • The aim of this study was to assess the effect of pre-aeration on sludge solubilization and the behaviors of nitrogen, dissolved sulfide, sulfate, and siloxane. The results of this study showed that soluble chemical oxygen demand in sewage sludge could be increased through pre-aeration. The pre-aeration process resulted in a higher methane yield compared to the anaerobic condition (blank). The pre-aeration of sewage sludge, therefore, was shown to be an effective method for enhancing the digestibility of the sewage sludge. In addition, this result confirms that the pre-aeration of sewage sludge prior to its anaerobic digestion accelerates the growth of methanogenic bacteria. Removal rates for $NH_3$-N and T-N increased simultaneously during pre-aeration, indicating simultaneous nitrification and denitrification. The siloxane concentration in sewage sludge decreased by 40% after 96 hr of pre-aeration; in contrast, the sulfide concentration in sewage sludge did not change. Therefore, pre-aeration can be employed as an efficient treatment option to achieve higher methane yield and lower siloxane concentration in sewage sludge. In addition, reduction of nitrogen loading by pre-aeration can reduce operating costs to achieve better effluent water quality in wastewater treatment plant and benefit the anaerobic process by minimizing the toxic effect of ammonia.

A Study on the Availability Modelling and Assessment with Failure Density Function of Major Equipment for a Sewage Treatment Plant (하수처리장 주요 기자재의 고장확률밀도함수를 이용한 가용도 모델링 및 평가에 관한 연구)

  • Lee, Hong-Cheol;Kwak, Pilljae;Lee, Hyundong;Hwang, In-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.763-768
    • /
    • 2013
  • The simulation investigation on the availability with failure density function of major equipment for a sewage treatment plant has been carried out. This study focuses on the availability of the plant and criticality with equipment module induced by component layout and its failure function. The equipment classification of sewage treatment plant and its failure function are established. Also solution methodologies are introduced as Monte-Carlo simulation method and event algorithm for uncertainty problem. The availability in the case of serial connection of equipment with all exponential function is calculated as around 50.4%. In other case of parallel combination with back up equipment, the availability showed over 80.1%. The criticality that a ffects availability showed high value over 77% in the dehydration and concentration process of sludge.

Comparing the Inflow Rate of Sewage Treatment Plants Invested by the Public Funds or Public-Private Partnership (PPP) Projects (재정사업과 민간투자사업의 하수처리장 하수유입률 특성분석)

  • Lee, Wonseok;Cho, Eunju;Son, Younggyu;Khim, Jeehyeong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.778-784
    • /
    • 2009
  • The purpose of this study is to figure out the differences of the inflow rates of Sewage Treatment Plants (STP), invested by public fund or public-private partnership (PPP). This paper finds that the average ratio of sewage inflow according to facility capacities (medium and small scale STP) was either nearly below 30% or above 100% in the first year. As the size of STP increased, there was decrease in the accuracy of demand assumption. This was because the operation time when the ratio of sewage inflow was uniform was different according to the size of STP, whereby the time was short when the STP were small. The design average ratio of sewage inflow was 10% larger than the real average ratio; this was considered overdesigned. In the case of a plant built by the PPP scheme, the average ratio of inflow of the STP before an abolition of MRG was larger than after the abolition of MRG. This may be explained by moral hazard from too much reliance on MRG. After the abolition of MRG, the demand risk of PPP was shifted from a PPP project to a conventional project.

Effects of Mixing Ratio and Organic Loading Rate of Acid Fermented Food Wastes and Sewage Sludge on the Anaerobic Digestion Process (음식물찌꺼기 산발효산물과 하수슬러지의 혼합비 및 유기물부하가 병합처리에 미치는 영향)

  • Ahn, Chul-Woo;Park, Jin-Sik;Jang, Seong-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.247-256
    • /
    • 2006
  • This study has been conducted for the process of food wastes disposal using surplus capacity of established sewage treatment plant by co-digestion of fermented food wastes and sewage sludge after thermophilic acid fermentation of food wastes. The co-digestion of thermophilic acid fermented food wastes and sewage sludge was performed by semi-continous method in mesophilic anaerobic digestion reactor. It showed great digestion efficiency as the average SCOD and VS removal efficiency in organic loading rate 3.30g VS/L.d. were 74.2% and 73.6%, and the gas production rate and average methane content were 0.440 L/g $VS_{add}.d$ and 66.5%, respectively. Based on the results of this study, the co-digestion of thermophilic acid fermented food wastes and sewage sludge in sewage treatment plant is able to improve treatment efficiency of anaerobic digestion reactor and to dispose food wastes simultaneously, and was proved excellent economical efficiency comparing with any other treatment methods.