• Title/Summary/Keyword: Sewage Treatment Facilities

Search Result 162, Processing Time 0.027 seconds

Evaluation and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Resources (음식물 자원화시설의 설치·운영에 대한 일반현황의 평가 및 개선 방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.63-75
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of domestic public resource-making facilities of resource-making facilities and come up with corresponding improvement measures. Currently compost is most numerous set-up out of facilties already established ever since, then the rest of them are feeds, anaerobic degradation, sewage combination, and combination of compost and feeds in order. As such, food waste is processed more into compost than into feeds, presumably because relevant facilities, which were originally designed for processing into feeds, were converted into composting facilities due to little demand for the processed feeds. The finding says that many related firms had yet to register their businesses in accordance with feeds and fertilizers management laws, and that food waste resources-making facilities used various basic facilities but few of them treated food waste in linkage with leaching water, bad odors, and energy. Some of current facilities were found to be 7 years old and thus outdated. Due to lack of skilled operational manpower, many facilities had less than 300 days of normal operation yearly, and some needed minor and serious repairs periodically. In overall facilities, 87% of the planned food waste was rolled in, thus requiring measures to treat the whole planned volume. For costs of resource-making facilities, some with a capacity of below 50 tons topped 100 million won, and facilities with a capacity of over 50 tons required less installation costs. Overall, installation costs ranged from 10 million to 20 million, and to 200 million won per ton, and this suggests a need to establish the installation cost calculation criteria, as well as to reshape the facility criteria. With operating costs varying greatly according to the size and treatment methods of facilities, the finding indicates a need to rationalize the operating costs, and to plan appropriate-size installation and operation of facilities to ensure economic operation.

  • PDF

Suggestions for Cost Improvement of High concentration Linked Treatment in Municipal Wastewater Treatment Plant (하수처리장에서의 연계처리수 요금 개선에 따른 경제성 분석)

  • Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.139-144
    • /
    • 2020
  • Recently, high-concentration linked wastewater has been introduced into a nearby municipal wastewater treatment plants(MWTPs), but it is difficult to MWTP in local governments due to an unreasonable linked treatment charge system, and there is insufficient evidence or data to prove this. However, the MWTP, which is a national essential infrastructure, is generally exempt from the preliminary feasibility study, so there have been no cases where economic evaluation was conducted. Therefore, we proposed an improvement plan that can compensate for the disadvantages of the existing linked processing charges through previous studies. In this study, a comparative evaluation of how much economic feasibility can be improved compared to the existing ones when applying the improvement plan by conducting an economic analysis. For this, reference was made to the preliminary feasibility assessment data of the existing environmental facilities and the cost factors and benefit factors established during the modernization of the old sewage treatment facilities. As a result of the study, the B/C(Benefit/cost) value was quite low in the past, but when the improvement proposal proposed by the researchers was applied, it was confirmed that the B/C value increased close to 1. Therefore, it is considered to be very reasonable to calculate the linkage processing charge according to the linked wastewater load proposed by the researchers.

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.

Endocrine Disruptive Potentials in Surface Water Samples from Taihu Lake, Yangtze Delta

  • Shen, L.;Lin, G.F.;Shen, J.H.
    • Toxicological Research
    • /
    • v.17
    • /
    • pp.319-321
    • /
    • 2001
  • Taihu Lake is a major water source for part of Yangtze Delta, which is one of the most urbanized and economically prosperous areas in China. In last couple of decades, some parts of the lake were highly polluted due to eutrophication. This study analyzed dioxin-like potential and mutagenic potential in surface water samples from Taihu Lake. The samples were prepared by XAD-2 resin procedure. A batch of biological assays, including dioxin-like potential microassay with the rat hepatocyte cell line H411E, and Ames test was employed in the research. Results showed that jour water samples have high content of dioxin-like biological potential, the highest activity TEQ to 2,3,7,8-TCDD was 48 pg/ι in sample 1. The mutagenic effect with reading-frame shifting mechanism was confirmed in 3 of 4 samples. The effective sewage treatment facilities and reliable monitoring surveillance system are urgently needed for this area.

  • PDF

Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics (시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구)

  • 전유신;문태훈
    • Korean System Dynamics Review
    • /
    • v.4 no.2
    • /
    • pp.71-94
    • /
    • 2003
  • The purpose of this dissertation is to build a development density control model and estimate optimum developmental density level for a sustainable urban growth management. To develop the model, system dynamics modeling approach was used. The model was developed to analyze how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. The model was applied to Anyang city to estimate optimum density level. Extensive computer simulation was conducted to find out the maximum numbers of population, industry structure, houses, and cars that can be adequately sustained with the current Anyang city's infrastructure capacity. The computer simulation result shows that the city is overpopulated by some 90,000 people. It nab analyzed that 20% increase of existing capacity of urban infrastructure is necessary to support current population of Anyang city. To reduce the population to the adequate level whereby the current urban infrastructure can sustain, the current city regulation on floor area ratio needs be strengthened at least 20% to 35%.

  • PDF

Performance Analysis of 10kW Class Propeller Hydro Turbine by the Change of Flow Rates and the Number of Runner Vane Using CFD (CFD를 이용한 10kW급 모델 실험용 프로펠러 수차의 유량 및 러너 베인 깃 수 변화에 따른 성능해석)

  • Park, Ji-Hoon;Kim, You-Taek;Cho, Yong;Kim, Byeong-Kon;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.2
    • /
    • pp.5-11
    • /
    • 2014
  • Small hydro power, among other renewable energy resources, has been evaluated to have enough development value because it is a clean, renewable and abundant energy resource. In addition, small hydro power has the advantage of low cost development by using existing facilities like sewage treatment plants, water works and similar resources. But in the case of small hydro power systems, there are problems with degraded operation efficiency of turbine due to changes in flow rates. In order to overcome this, variable speed control can be achieved by using the power rectifier and permanent magnetic synchronous generator(PMSG) as a possible method to respond to the changes in flow rates. In this study, a commercial ANSYS CFD code was used to analyze the performance of 10kW class propeller hydro turbine and to also investigate flow characteristics at variable flow rates and runner vane.

A Study on the Behavior Change of Zebrafish For Toxicity Evaluation of Residual Psychoactive Medication in Wastewater Treatment Plant Effluent (하수처리시설 방류수 내 잔류 향정신성 의약품의 독성평가를 위한 zebrafish의 행동성 변화 연구)

  • Yoon, Hyojik;Kim, Minjae;Kim, Jongrack;Kim, Sungpyo
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.574-579
    • /
    • 2019
  • As interest in health issues increases, it is imperative to ensure good water quality from wastewater treatment plant effluent to preserve environmental health. In particular, currently there is a lack of water ecosystem risk assessment on pharmaceutical substances remaining in effluent. In this study, antidepressant escitalopram (ESC), antiepileptic carbamazepine (CBZ) and lead, which impact the behavior of aquatic organisms, were used to test their impact on the potential behavior of zebrafish. Zebrafish have been widely used in toxicological assessment studies due to the ease of handlinggenerically and genetically. It was possible to observe changes in the growth of organisms through monitoring the embryos' cognitive and behavior assessment. In this study, the embryo lethal dose test showed that the lethal concentration of ESC and CBZ was at 10 ppb, which is below the water quality criterion (100 ppb), increased by 32.5 % and 40 %, respectively. In the cognitive test, it was found that the cognitive ability function decreased by 22 % and 17% for ESC(500 ppb) and CBZ(1,000 ppb) respectively relative to control. Based on these results, it is necessary to initiate efforts to remove these trace pollutants from sewage treatment facilities to protect the health of aquatic organisms.

The Reclamation of Secondary Effluent to Industrial Water by Co-60 γ Irradiation (Co-60 γ선을 이용한 하수처리수의 공업용수로의 재이용)

  • Lee, Myun-Joo;Jeoung, Young-Do;Nho, Young-Chang;Shon, Jong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.838-842
    • /
    • 1999
  • In order to reclaim the effluent discharged from sewage treatment facilities application of an irradiation technique was investigated in this study for industrial water reuse. Samples were filtered using a sand filter to remove particles. Co-60 was used as an irradiation source and the irradiation dose was varied from 0.1 kGy to 15 kGy. The major source of colour in secondary treatment effluent was humic substances, which could be easily removed by irradiation with a dose 5 kGy. Bacteria could be also disinfected even at low doses. It was possible to get high quality water for industrial water reuse. But the effluent still contained a small amount of organic compounds. Further treatment, of residual organic compounds will be necessry if the higher quality water is required.

  • PDF

The Present Status of Standard Sludge Characterization Method (슬러지 성상평가방법의 표준화 현황)

  • Kim, Tak-Hyun;Park, Chul-Hwan;Kim, Sang-Yong
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.87-98
    • /
    • 2007
  • As the interest in environmental problems increased, the guideline of effluent qualities becomes strict and the amount of sludge produced from the wastewater treatment facilities steeply increased. The revised Korean acts prohibit the direct reclamation of the sludge exhausted in sewage treatment works from 2003, and the ocean dump of sludge will be also prohibited from 2012. Therefore, the sludge must be recycled, incinerated or composted. To properly perform the utilization and disposal operations, the establishment of well-defined procedures for the characterization of sludge by physical, chemical and biological method and setting up of guidelines for different treatment and disposal routes has become necessary. However, there have not been such standardized methods for sludge characterization in Korea. This review analyzes the present status of establishment and problems of sludge characterization method of Korea. Finally, it was proposed total 15 items of standardized characterization methods suitable to our country for proper sludge recycling and disposal, which was based on the more systematic standard methods of Germany (DIN 38414) and those of advanced nations.

  • PDF

Development of Ultrasonic Multi-Beam Sludge Meter For Effluent Facilities Automation (정수장에서 배출수 공정 자동화를 위한 초음파 다중빔 슬러지 농도계 개발)

  • Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2313-2321
    • /
    • 2014
  • A concentration meter is widely used at purification plants, sewage treatment plants and waste water treatment plants to sort and transfer high concentration sludge and to control the amount of chemical input. This study has been prepared for improving efficiency of operation on sludge processes and to establish a basic for factory automation by accuracy improvement and problem solution of sludge concentration meter. The concentration meter's accuracy and stability is improved by applying multi-beam sensors and minimum deviation linear average filtering. Furthermore maintenance without cut-off of water in sludge operation is possible by detachable sensors. The performance of multi-beam concentration meter has been variously verified by the pilot plant experiment.