• 제목/요약/키워드: Sewage Treatment Efficiency

검색결과 342건 처리시간 0.026초

수평 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리 (Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment)

  • 서정윤;김은호
    • KSBB Journal
    • /
    • 제21권1호
    • /
    • pp.28-33
    • /
    • 2006
  • 제올라이트로 충진된 수평 흐름 갈대 여과상에 실제하수를 간헐적으로 주입하면서 처리효율을 조사하였다. 여과상 표면적 $m^2$당 1일 314 L의 하수가 6시간마다 10분 동안 간헐적으로 주입되었다. 처리수의 pH는 원수보다 감소하였으며, 용존산소 농도는 원수보다 증가하였다. 수평 흐름 여과상에서 각 항목별 연중 평균 처리효율은 SS $88.5%,\;COD_{cr},\;86.1%,\;COD_{Mn}\;81.0%,\;T-N\;48.6%,\;NH_4^+-N\;97.1%$, T-P 42.8%이었다. 수평 흐름 여과상에서 처리수 중 T-N의 대부분은 $NO_3^--N$이었으며 $NO_2^--N$의 농도는 0.10 mg/L 이하이었다. 처리효율의 계절적 차이는 없었다.

하수도 기술의 평가 인증제도 운영현황 및 방향 (Current Status of Sewerage Technology Evalution Verification System and Direction for Improvement of the System)

  • 이상은
    • 수도
    • /
    • 제24권5호통권86호
    • /
    • pp.16-28
    • /
    • 1997
  • As sewerage works has become one of the major public works in Korea, the employment of advanced and more appropriate sewerage technology has become essential to improve the efficiency of sewerage works. During last 10 years, the Korean Government has made tremendous amount of investment on sewerage works so that treatment plants in 58 cities have treatment capacity which is equivalent to 52.8% of total daily sewage generation in Korea. This remarkable development, however, has heavily depended on one technology, the conventional activated sludge process as more than 95% of the existing plants employ this process, Recently, the Korean Government and local authorities have plans to introduce more appropriate sewage treatment technologies and research and development in this area has become very active. To encourage employing new and appropriate technologies, however, the proper technology evaluation and verification program for new process is needed. The public sector should play a key role in this program since the sewerage works is one of the major public works. In this paper, the technology evaluation and verification programs related with sewerage facilities in the US and Japan are briefly reviewed. The Innovatived and Alternative Technology programs which was operated by US EPA until recently and Environmental Technology Verification(ETV) program which was commenced in 1995 are introduced. The technology verification programs operated in Japan and also in Korea are also reviewed in this paper to propose a future direction for development of the appropriate evaluation and verification system.

  • PDF

자연정화공법에 의한 하수처리장에서 오염물질의 존재형태별 처리효율 (Treatment Efficiency of Existing Forms of Pollutants in Sewage Treatment Plant by Natural Purification Method)

  • 서동철;이병주;황승하;이홍재;조주식;이상원;김홍출;허종수
    • 한국환경농학회지
    • /
    • 제25권2호
    • /
    • pp.129-137
    • /
    • 2006
  • 농촌 마을단위 하수처리장에서 오염물질의 존재형태별 처리 경향을 파악하여 하수처리장의 설계 및 시공시 부지면적 감소와 오염물질의 처리효율 극대화를 위한 기초자료로 활용하기 위하여 농촌 마을 단위 하수처리장을 호기성조와 혐기성조로 구분하여 시공한 다음 하수처리 경과시기별, 오염물질 부하량별 및 계절별로 각 오염물질의 존재형태별 수처리 효율을 조사하였다. 하수처리 경과시기에 따른 오염물질 처리효율을 조사한 결과 호기성조 처리수에서 하수처리 시간이 경과함에 따라 BOD, COD, TOC 및 SS처리량은 큰 폭으로 증가하였다. 처리된 오염물질의 존재형태를 조사한 결과 호기성조 및 혐기성조에서 BOD는 대부분 IBOD로, COD는 대부분 ICOD로, TOC는 대부분 STOC로, SS는 대부분 VSS로, T-N은 대부분 DTN 및 T-P는 대부분 DTP로 처리되었다. 부하량별 오염물질 처리효율을 조사한 결과 BOD 처리량은 호기성조와 방류수 모두에서 처리된 대부분의 BOD는 IBOD이었다. COD 처리량도 BOD와 유사하게 호기성조에서는 대부분 ICOD형태로 처리되었으나, 혐기성조에서는 ICOD와 SCOD가 비슷한 처리량을 보였다. 그러나 하수처리장에서 처리되는 TOC의 존재형태별 처리량은 BOD 및 COD와는 달리 호기성조 처리수와 방류수 모두에서 STOC의 처리량이 약간 많았다. 부하량별 SS 처리효율은 호기성조 처리수에서 95%정도 처리되어 대부분의 SS는 호기성조에서 처리되었으며, 처리되는 SS의 용존형태는 호기성조 처리수에서는 대부분 VSS로 처리되었고, 방류수에서는 VSS와 FSS가 비슷한 양으로 처리되었다. 부하량별 T-N 처리효율은 호기성조 처리수에서 32%정도이었고, 방류수에서 24%정도이었다. 또한 처리되는 T-N의 용존형태는 호기성조 처리수와 방류수 모두에서 DTN이 STN에 비해 월등히 많은 양이 처리되었다. 부하량별 T-P 처리효율은 호기성조에서 62%정도이었고, 혐기성조에서 14%정도로 대부분 호기성조에서 처리되었으며, 처리되는 T-P의 용존형태는 호기성조와 방류수 모두에서 대부분 DTP형태이었다. 계절별 오염물질 처리량을 조사한 결과 BOD, COD, TOC, SS, T-N 및 T-P 처리량은 여름과 가을이 봄과 겨울에 비해 처리량이 약간 증가되었으며, BOD, COD, TOC, SS, T-N 및 T-P는 4계절 모두 방류수의 처리효율이 각각 92, 89, 73, 95, 46 및 84%이상의 높은 처리효율을 나타내었다.

하수슬러지의 열처리에 의한 가용화효과 및 고온산발효의 분해효율에 미치는 영향 평가 (Effect of Heat Treatment of Sewage Sludge on Solubilization and Thermophilic Acid fermentation efficinecy)

  • 박용진;쓰노 히로시;히다카 타이라;김석구
    • 유기물자원화
    • /
    • 제15권2호
    • /
    • pp.89-97
    • /
    • 2007
  • 본 연구에서는 하수슬러지의 가용화를 위한 처리공정으로 열처리를 수행하였다. 열처리에 의하여 입자상 유기성분의 가용화를 확인할 수 있었다. $120^{\circ}C$ 30분의 열처리에 의하여 1차 슬러지의 경우 COD기준 8.3%의 가용화효과를 나타내었다. 반면 2차슬러지의 경우 16.5%의 높은 값을 보여주었고 이는 단백질의 높은 가용화 효과에 기인하는 것으로 나타났다. 한편 모든 슬러지에 대하여 열처리에 따른 분해율 및 유기산 생성율의 향상을 확인 할 수 있었다. 단 산발효 실험을 통하여 최적 열처리조건은 대상 기질의 유기물 조성에 따라 결정되는 것으로 판단되었다. 즉 탄수화물의 함량이 높았던 1차슬러지의 경우 $80^{\circ}C$ 30분의 열처리를 통하여 최대의 분해율과 유기산 생성효과를 얻었으며 단백질의 함량이 높았던 2차 슬러지의 경우 $120^{\circ}C$ 30분이 최적의 열처리 조건인 것으로 나타났다.

  • PDF

전구물질의 소수성 및 친수성 특성에 따른 트리할로메탄의 생성과 제거에 관한 연구 (Formation and Removal of Trihalomethanes based on Characterization of Hydrophobic and Hydrophilic Precursors)

  • 전희경;김준성;최윤찬;최해연;정용
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.123-128
    • /
    • 2008
  • The Dissolved Organic Carbon (DOC) existing in a water includes both hydrophobic and hydrophilic substances however, most of the discussion focuses on hydrophobic substances. The hydrophobic fraction was easily removed by absorption or coagulation more than hydrophilic fraction. Therefore, control of the hydrophilic fraction is very important in water treatment process. This study is to determine the variation of DOC, the removal efficiency of DOC, and Trihalomethane formation potential (THMFP) after each stage of water treatment process by fractionating Natural Organic Matters (NOM) into hydrophobic and hydrophilic substance. DOC from raw water was fractionated at acidic pH (pH<2) using XAD 8 resin column, into two fraction : hydrophobic substance (i.e. humic substance) adsorbed on XAD 8 and hydrophilic substance which represent the organics contained in the final effluent. THMFP was carried out according to the following set condition: Cl2/DOC=4 mg/mg, incubation at $25^{\circ}C$ in darkness, pH 7 adjust with HCl or NaOH as necessary, and 72hour-contact time. THMs analyzed in this study were chloroform, bromodichloromethane, dibromochloromethan, and bromoform. Sewage was almost evenly split between the hydrophobic (56%) and hydrophilic fraction (44%). But, Aldrich humic substance (AHS) was found to contain less hydrophilics (14%) than hydrophobics (86%). The formation of THMs may depend on the source which is characterized by the composition of organic matters such as AHS and sewage. The THMFP yield of sewage and AHS were assessed as follows. The value of the THMFP reaction yield, AHS $172.65{\mu}g/mg$, is much higher than that of sewage $41.68{\mu}g/mg$. This illustrates possible significant difference in THMFP according to the component type and the proportion of organic matter existing in water source. Apparently AHS react with chlorine to produce more THMFP than do the smaller molecules found in sewage. Water treatment process may reduce THMFP, nevertheless residual DOC (the more hydrophilic substance) has significant THMFP. Further reduction in organic halide precursors requires application of alternative treatment techniques.

막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리 (Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제24권1호
    • /
    • pp.20-30
    • /
    • 2014
  • C/N 비가 낮은 농촌마을 하수의 고도처리를 위하여 $0.4{\mu}m$의 세공크기를 갖고 있는 평막이 침지된 연속회분식 반응기를 사용하였다. 분말활성탄의 투입, 폭기량 및 유입 유기물 농도가 처리효율과 여과 성능에 미치는 영향을 조사하였다. 54일 이내의 조업 초기에서는 C/N 비가 증가할수록 COD, T-N 및 T-P의 제거율과 MLSS 농도는 증가하였다. 조업 89일 후의 COD, T-N 및 T-P의 제거율은 각각 97.1%, 75.0% 및 48.3%이었다. 막여과에 의해 처리수에서 SS는 검출되지 않았으며, T-P의 제거율이 낮게 나온 이유는 과잉의 슬러지를 배출하지 않았기 때문이다. 분말활성탄을 투여한 경우 조업이 진행됨에 따라 분말활성탄의 혼합강도와 충돌빈도가 증가하여 슬러지의 입자크기가 감소하였으며, 이로 인해 분말활성탄을 투여하지 않은 경우에 비해 TMP 상승이 크게 나타났다.

미세기포 오존과 생물여과 시스템을 이용한 생활하수의 3차 처리에 관한 연구 (Tertiary Treatment of Sewage by Micro Bubble Ozone and BAF System)

  • 강동한;장영호;김종수;김극태
    • 한국물환경학회지
    • /
    • 제27권6호
    • /
    • pp.877-884
    • /
    • 2011
  • In this paper, the removal characteristics of dissolved organic carbon (DOCs) by micro bubble ozonation process and $O_3/UV$ process were comparatively studied. In the point of DOC removing reaction coefficient, micro bubble ozonation system and $O_3/UV$ process had not significant difference, $0.0120sec^{-1}$ and $0.0141sec^{-1}$. Therefore micro bubble ozonation process is more suitable for tertiary treatment of sewage in the point of installation and maintenance cost-reducing. The optimum ozone injection rate was 2.0 g $O_3/g$ DOC and HRT was 3 min for the micro bubble ozonation process. The removal efficiency of DOC and SUVA in micro bubble ozonation system was 32.8% and 58.3% respective. Biological aerated filter (BAF) process was installed to remove soluble organic material increased by micro bubble ozonation system. And the effluent BOD of BAF was below 1.0 mg/L. In the view of cost-effectiveness, $O_3/BAF$ process was more profitable than $O_3/UV/BAF$ process for tertiary treatment of sewage. In order to nitrify ammonia in the BAF process completely, $NH_4{^+}-N$ concentration in the influent water of BAF should be designed considering low water temperature in the winter season.

EQPS 모델을 이용한 하수처리장 운전 평가 (Evaluation of Operational Options of Wastewater Treatment Using EQPS Models)

  • 유호식;안세영
    • 한국도시환경학회지
    • /
    • 제18권4호
    • /
    • pp.401-408
    • /
    • 2018
  • 하수처리 공정모델링 소프트웨어인 EQPS(Effluent Quality Prediction System, Dynamita, France)를 적용하여 A하수처리시설 생물반응조 설계의 적합성을 분석하였다. A하수처리장은 친수용수 수준의 목표수질을 준수하기 위하여 이차침전지 유출수 설계농도를 총질소와 총인, 각 10 mg/L, 1.8 mg/L로 설정하여 설계하였다. 4-Stage BNR 공정인 반응조의 체류시간은 총 9.6시간으로 전무산소조 0.5, 혐기조 1.0, 무산소조 2.9, 호기조 5.2시간이었다. 동절기 공정모델링 결과 친수용수 수준의 목표수질을 만족하기 위하여 혐기조의 체류시간을 0.2시간 늘렸고 당초 설계조건이던 외부탄소원 비상시 주입을 상시적으로 주입해야 하는 것으로 조사되었다. 모델링 결과의 왜곡을 배제하기 위하여 소프트웨어 제조사가 제시한 one step nitrification denitrification 모델의 Default 계수를 사용하였다. 공정모델링은 대체적으로 최적의 상태를 제시하기 때문에 생물반응조 여유율을 고려하면 4-Stage BNR의 체류시간은 9.8시간보다 증가시켜야 한다. 하수처리장 설계단계에서 공정 모델링의 정확한 사용은 하수처리장 건설 후 처리성능과 효율의 안정성을 담보할 수 있는 방법이므로 설계단계에서 철저한 평가가 필요하다.

유기물부하에 따른 음식물찌꺼기의 산발효 특성 (Acid Fermentation Characteristic of Food Wastes According to the Organic Loading Rate)

  • 박진식;안철우;장성호
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.975-982
    • /
    • 2006
  • This study has been conducted to optimum operating conditions for effective acid fermentation according to OLR(organic loading rate) in the mesophilic and thermophilic acid fermentation process. The results are summarized as follows. In order to obtain reasonable acid fermentation efficiency in performing acid fermentation of food wastes in thermophilic condition, organic loading rate was required below 20 gVS/L.d. As $SCOD_{Cr}/TKN,\;SCOD_{Cr}/T-P$ of thermophilic acid fermented food wastes In organic loading rate 20 gVS/L.d were 18.9, 73.4 respectively, it was possible to utilize as external carbon source for denitrification in sewage treatment plant after solid-liquid separation as well as co-digestion of fermented food wastes and sewage sludge.

생흡착을 이용한 생활하수의 염양염류제거에 관한 고도처리 연구 (A study on advanced treatment of domestic wastewater nutrient removal by using Biosorption)

  • 박주석;김현갑;안창환;황정기;안상준
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.29-35
    • /
    • 1999
  • The purpose of this study is to remove the organics, nitrogen and phosphorus using biosorption for the domestic sewage. The new process using biosorption is based on the methods of contact-stabilization, which remove the organics by absorbing them to the surface of the microorganism in the activated sludge. This process consists of biosorption reactor, biosorption clarifier, nitrifying reactor, nitrifying clarifier, denitrifying reactor, phosphorus uptake(polishing) reactor and final clarifier. The efficiency of removal could be reached 91% for organics, 76% for nitrogen, 90% for phosphorus in Eujungbu pilot plant. We operated the plant which irrigated $10m^3$ per day for sewage. During our operation the HRT(Hydraulic Retention time) was maintained for 10.5hr, but it could be reduced as 8.5hr according to our operation results.

  • PDF