• 제목/요약/키워드: Seven Joint

Search Result 328, Processing Time 0.026 seconds

A Study on Optimal Working Path Control of Seven Axes Vertical Type Robot with Translation Joint for Triming Working Automation in Forming Process (단조공정 트리밍작업 자동화를 위한 병진관절을 갖는 7축 다관절 로봇의 최적 작업경로제어에 관한 연구)

  • Kim, Min-Seong;Choi, Min-Hyuk;Bae, Ho-Young;Im, Oh-Deuk;Kang, Jung-Suk;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.2
    • /
    • pp.53-62
    • /
    • 2018
  • This study propose a new approach to control the optimal working path of vertical type articulated robot with translation joint for trimming working process automation in forging manufacturing process. The basic structure of the proposed robotic joints controller consists of a Proportional-Intergral controller and a Proportional-Derivative controller in parallel. The proposed control scheme takes advantage of the properties of the fuzzy PID controllers. The proposed method is suitable to control of the trajectory and path control in cartesian space for vertical type articulated robot manipulator. The results illustrates that the proposed fuzzy computed torque controller is more stable and robust than the conventional computed torque controller. The reliability is varified by simulation test for vertical type s articulated robot with seven joints including one trqanslation joint.

Temporomandibular joint dislocation: experiences from Zaria, Nigeria

  • Agbara, Rowland;Fomete, Benjamin;Obiadazie, Athanasius Chukwudi;Idehen, Kelvin;Okeke, Uche
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.111-116
    • /
    • 2014
  • Objectives: Dislocation of the temporomandibular joint may occur for various reasons. Although different invasive methods have been advocated for its treatment, this study highlights the value of non-invasive treatment options even in chronic cases in a resource-poor environment. Materials and Methods: A seven-year retrospective analysis of all patients managed for temporomandibular joint dislocation in our department was undertaken. Patient demographics, risk factors associated with temporomandibular joint dislocation and treatment modalities were retrieved from patient records. Results: In all, 26 patients were managed over a seven-year period. Males accounted for 62% of the patients, and yawning was the most frequent etiological factor. Conservative treatment methods were used successfully in 86.4% of the patients managed. Two (66.7%) of the three patients who needed surgical treatment developed complications, while only one (5.3%) patient who was managed conservatively developed complications. Conclusion: Temporomandibular joint dislocation appears to be associated with male sex, middle age, yawning, and low socio-economic status, although these observed relationships were not statistically significant. Non-invasive methods remain an effective treatment option in this environment in view of the low socio-economic status of the patients affected.

A Classification Techniques of Solder Joint Using Neural Network in Visual Inspection System (시각 검사 시스템에서 신경 회로망을 이용한 납땜 상태 분류 기법)

  • 오제휘;차영엽
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.26-35
    • /
    • 1998
  • This paper presents a visual inspection algorithm looking for solder joint defects of IC chips on PCBs (Printed Circuit Boards). In this algorithm, seven features are proposed in order to categorize the solder joints into four classes such as normal, insufficient, excess, and no solder, and optimal back-propagation network is determined by error evaluation which depend on the number of neurons in hidden and out-put layers and selection of the features. In the end, a good accuracy of classification performance, an optimal determination of network structure and the effectiveness of chosen seven features are examined by experiment using proposed inspection algorithm.

  • PDF

Unequal depth beam to column connection joint

  • Ben Mou;Aijia Zhang;Wei Pan
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.823-837
    • /
    • 2023
  • This paper presents the seismic performance of seven beam-column joints with an eccentricity between beam depths under cyclic loadings. The failure modes of the panel zone were divided into two types. One was the shear force failure that appeared in the entire panel zone (SFEPZ), the other was the shear force failure that appeared in the partial panel zone (SFPPZ). Seven finite element models were established using multi-scale methods. Compared with the experimental specimens, the hysteretic loops exhibited a similar trend. The multi-scale models could accurately simulate the experimental results. Furthermore, the calculation formulas of yield and plastic shear capacity of unequal-depth joints with outer annular stiffener were proposed.

The effects of stirrups and the extents of regions used SFRC in exterior beam-column joints

  • Gencoglu, Mustafa
    • Structural Engineering and Mechanics
    • /
    • v.27 no.2
    • /
    • pp.223-241
    • /
    • 2007
  • Seven full-scale exterior beam-column joints were produced and tested under reversible cyclic loads to determine. Two of these seven specimens were produced using ordinary reinforced concrete (RC). Steel Fiber Reinforced Concrete (SFRC) was placed in three different regions of the beams of the rest five specimens to determine the extent of the region where SFRC is the most effective. The extent of the region of SFRC was kept constant at the columns of all five specimens. Three of these five specimens which had one stirrup in the joint, were tested to evaluate the effect of the stirrup on the behavior of the beam-column joint together with SFRC. In production of the specimens with SFRC, all special requirements of the Turkish Earthquake Code related to the spacing of hoops were disregarded. Previous researches reported in the literature indicate that the fiber type, the volume content, and the aspect ratio of steel fibers affect the behavior of beam-column joints produced with SFRC. The results of the present investigation show that the behavior of exterior beam-column joints depends on the extent of the region where SFRC is used and the usage of stirrup in the joint, in addition to the parameters listed in the literature.

Extended Indications of Bilhaut-Cloquet Procedure for Type III and IV of Duplicated Thumb (무지 다지증 III, IV형의 치료에 Bilhaut-Cloquet 방법의 적극적 이용)

  • Lim, Young-Bin;Seul, Jung-Hyun;Nam, Hyun-Jae;Woo, Sang-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.821-828
    • /
    • 2011
  • Purpose: The authors applied Bilhaut-Cloquet procedure to Wassel type III and IV duplicated thumb, which was limited to patients with Wassel type I, II. This procedure was applied in order to improve the growth potential, range of joint motion, joint stability and cosmetic outcome. Methods: Sixteen patients received Bilhaut-Cloquet procedures to correct duplicated thumbs from May, 2005 to December, 2010. Seven patients were Wassel type III, nine patients were type IV. This procedure was applied not only to balanced type, but also unbalanced type or convergent type. Five patients were balanced type and eleven patients were unbalanced type. Convergent type of Wassel type IV was three. Sex ratio was the same, mean age at the operation was 20.1 months old (8~52 months old). Angular deformity, joint stability and range of joint motion and cosmetic outcome were considered together and estimated in Tada score. Also, postoperative subjective satisfaction score of the parents was evaluated by a 100-points scale. Results: Mean subjective satisfaction scored 75 points at 28 months after the operation. Radiologic study showed bony union of proximal phalangeal bone and stable joint in all patients. Range of motion was mean 20 degrees in interphalangeal joint and mean 73 degrees in metacarpophalangeal joint. Tada score showed 'good' in eleven patients (68.8%), 'fair' in three patients (18.7%) and 'poor' in two patients (12.5%). In seven patients those who were able to follow up for a long term showed no significant difference in length of proximal and distal phalangeal bones compared to the opposite thumb. Conclusion: Bilhaut-Cloquet procedure can be applied not only to balanced type of Wassel type III, IV duplicated thumb, but also to unbalanced type or convergent type that focused on functional reconstruction and cosmetic improvement.

The Analysis of Joint Motion of Lower Extremities to Running Velocities and Cutting Angles (달리기 속도와 방향전환 각도에 따른 하지관절 움직임 분석)

  • Kwon, Oh-Bok;Jung, Chul-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.9-16
    • /
    • 2007
  • Cutting movements frequently occur in sports and influence much Lower Extremity injuries. The purpose of this study was to compare joint motion of lower extremities to cutting angles and running velocities. Seven male subjects performed cutting movements to three angles($0^{\circ}$, $30^{\circ}$, $60^{\circ}$). Subjects were instructed to run five meters at a speed of 2.5m/s and 4.5m/s before contacting their right foot on the force plate and then change direction to the left. The Peak hip, knee and ankle joint kinematics were influenced according to the running velocities and cutting angles. In conclusion, Fast running velocity and cutting angle will may influence on the lower extremity joint instability on real game situation.

Effects of Different Types of Attentional Focus on Dart Throwing Mechanics (주의 집중 방법이 다트 던지기 역학에 미치는 영향)

  • Kim, Hye-Ree;Kong, Se-Jin;Kim, Soo-Yeon;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.327-333
    • /
    • 2013
  • The purpose of this study was to investigate the effects of different types of attentional focus(internal focus vs. external focus) on the dart throwing mechanics. Seven expert dart throwing athletes were assigned to an internal focus group and other seven athletes were assigned to an external focus group. Each group was asked to throw dart either under verbal instruction or without instruction. During dart throwing, accuracy(radial error), consistency(bivariate variable error), dart velocity, acceleration, elbow joint ROM, elbow joint angular velocity, EMD(electromechanical delay), iEMG of biceps brachii and triceps brachii, and CI(coactivation index) were collected and analyzed. Nither instruction type nor instruction itself affected in accuracy and consistency. However, in dart velocity and acceleration, there was an interaction between instruction and attentional focus types. Velocity and acceleration increased in the internal condition, where as they decreased in the external condition. The ROM of elbow joint did not affected by instruction and attention type. However, similar to dart velocity and acceleration, angular velocity increased in internal focus group, while it decreased in external focus group. EMG showed no difference with any condition. In conclusion, internal focus is better than external focus for dart throwing.

Comparison of Costochondral Graft and Customized Total Joint Reconstruction for Treatments of Temporomandibular Joint Replacement

  • Lee, Woo-Young;Park, Young-Wook;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.135-139
    • /
    • 2014
  • Purpose: We review published research on temporomandibular joint (TMJ) total replacement that compares costochondral graft and customized total joint reconstruction (especially TMJ concepts), focusing on effectiveness. Methods: We searched PubMed databases, including prospective, retrospective, case-control or longitudinal studies and significant statistical analysis. In data analysis, we divided outcomes into 'Acceptable' or 'Non-acceptable'. Results: There were seven articles found dealing with costochondral graft and 180 patients. The majority of patients had satisfactory treatment outcomes (n=109, 61%). There were six articles including 275 patients using the alloplastic material TMJ concepts. Almost all patients had satisfactory treatment outcomes (n=261, 95%). Conclusion: Comparing customized total joint reconstruction with costochondral graft, use of TMJ concepts resulted in increased quality of life and fewer complications. In conclusion, we judged that alloplastic material such as TMJ concepts is more effective device in total joint replacement than costochondral graft.

A Study of Measurement on Range of Arm Joint Motion of Korean Male in Twenties (한국인 20대 청년의 팔 관절 동작범위 측정 연구)

  • 이영신;이석기;박세진;김철중
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.62-71
    • /
    • 1995
  • This paper measured the range of arm joint motion for Korean 54 male in twenties. The subjects are measured directly using Goniometer and angle gauge. The static measurement variables are seven and the dynamic measurement variables are thirteen. The anthropometric datum are analyzed by basic statistical analysis, correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach, 1978.

  • PDF