Sludge Transportation by the Submerged Barrier (수중격벽을 이용한 슬러지이송)

  • Park, Suk Gyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.857-865
    • /
    • 2006
  • The submerged barrier, employed in a reactor, divided a reactor into sludge settling zone and mixing zone according to flow type. In spite of mixing in the mixing zone, the lower part of sludge settling zone than the top of barrier was in a steady flow due to the barrier, which prevented the turbulent flow, produced from the mixing zone, from being diffused into the sludge settling zone. Therefore, the sludges in the mixing zone flowed backward over the barrier into the upper part of the sludge settling zone by turbulent flow and settled down in the sludge settling zone by the force of gravity. When barrier/water level ratio was 0.5, most sludges almost did not settle down in tile sludge settling zone because the sludges were directly affected by the turbulent flow, generated from mixer in the mixing zone. At 0.63 of barrier/water level ratio, sludge in the middle part of sludge settling zone rocked from side to side weakly. And sludge in the lower part became piled up on the bottom over this ratio. After 10minutes of sludge settling, the lower part of sludge settling zone was over 5000mg/L of sludge concentration although intial sludge concentration was 2300mg/L. By using the submerged barrier and the flow types, it could transfer sludge from this to that.

Morphological Parameters of the Sludge Flocs in a Long Rectangular Secondary Settling Tank (장방형 침전지에서 길이에 따른 슬러지 floc의 형태에 관한 연구)

  • Kim, Youngchul;Lee, Jin-Woo;Kang, Min-Gi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.468-474
    • /
    • 2006
  • In the secondary settling tanks, three different types of settling phenomena occurs; i.e., zone settling for sludge thickening in the bottom part of settling tank, and discrete and flocculent settling for clarification in the upper part. In this paper, morphological parameters of the floc in sludge blanket layers along the length of a long rectangular tank were investigated. The plant used for this study had a serious bulking problem caused by Microthrix parvicella. Floc size decreased as the surface area of settling tank increases, which indicates that in the secondary settling tank where zone settling believed to be predominant, free or flocculent type of settling contributes to floc size distributions. Large floc particles deposit in the front zone of settling tank, but small and loose flocs mostly in the zone near its outlet. On the other hand, filament length contained in one gram of sludge blanket solid increases along the flow direction. Large flocs with less filaments settle faster, but small flocs having more filaments result in poor settling. These results support function of microorganism selection occurring in secondary settling tank. In addition, designing a long rectangluar settling tank with double hoppers might be one of the ways of bulking control, but this idea has to be verified with a further study.

Settling Characteristics of Water Treatment Plant Sludges by Pretreatment Methods (정수장슬러지의 전처리에 의한 침전특성)

  • Moon, Yong-taik;Lee, Sun-ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.627-632
    • /
    • 2008
  • It is necessary to investigate methods for improvement by diagnosing sludge settling characteristics on inflow of slurry to thickener. The results of the settling tests are correlated to determine zone settling velocities at the various sludge solids concentrations. Conditioning of WTP residuals is generally done by either chemical or physical treatment. The settling test was conducted with 1m columns dosing polymer to WTP residuals at various solids concentration. The estimated results for dosing to WTP residuals for a sludge of 2,100 ~ 16,012 mg/L solids concentration were the zone settling velocities of 48.38 ~ 6.8 m/day, supernatant solid concentration of 3.2 ~ 19 mg/L and solid flux of $101.6{\sim}317.61kg/m^3{\cdot}day$. The values for non-polymer treatment were the zone settling velocities of 28.37 ~ 0.12 m/day, supernatent solid concentration of 8.5 ~ 108 mg/L and solid flux of $59.58{\sim}1.92kg/m^2{\cdot}day$. The limiting solid flux value by Yoshioka methods was $4.0kg\;TS/m^3{\cdot}day$ for Non-polymer and $228.0kg\;TS/m^3{\cdot}day$ for dosing polymer. These results are to indicate a possibility of improvement on the thickening characteristics and the quality of supernatant as increasing the settling velocities by dosing polymer to WTP residuals.

Characterization of Activated Sludge Settlings in Korea (국내 하수처리장 활성 슬러지의 침전특성에 관한 연구)

  • Lee, Hwangu;Kim, Youngchul;Choi, Euiso
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.964-971
    • /
    • 2009
  • In this paper, activated sludge settling was characterized based on field trip and zone settling tests. Plants used for this study include 5 conventional activated sludge processes and 3 A2O type treatment processes. The treatment capacities are in the range from 12,000 to $250,000m^3$/day. Total number of zone settling tests were 188 set and SVI values representing settling characteristics were from 100 to 300 mL/g. It was found out that zone settling velocity of these examined plant sludges can be approximated by mean values calculated by Keinath and Daigger/Roper models. Based on these three models, solid flux analysis were carried out in order to compare design criteria ($3.96{\sim}6.04kg/m^2-hr$) recommended by Korea Sewage Facility Design Guideline with two models used in USA. The results show that design criteria are only applicable for normal condition in settling characteristics (below SVI 100 mL/g). Solid flux analysis of surveyed plants indicates that most of the plants are operated underload conditions except several plants experiencing poor sludge settling problem. Most of the plants are operated under high sludge blanket depths (SBD).

Study on Sludge Concentration Change in Batch Column (Batch Column에서의 슬러지농도변화에 대한 연구)

  • Park, Suk Gyun;Kang, Seon-Hong;Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.443-450
    • /
    • 2006
  • For understanding sludge concentration profile as a function of time, sludge was sampled at each sampling port. When sludge concentration was 3g/L, the vertical sludge concentration distribution was similar to that of 2g/L of sludge concentration. During the early stage of sludge settling, sludge concentration increased remarkably as the sludge interface height in batch column became lower. The higher sludge concentration became, the worse sludge setteability became. Also, the type of sludge settling was influenced with sludge concentration gradient in batch column. In the same concentration, the greater sludge concentration gradient was, the faster sludge interface settled down. And the changing sludge concentrations in a batch settling or a continuous settling were simulated by using the equation of sludge interface height change model.

Modeling of non-isothermal CO2 particle leaked from pressurized source: II. Behavior of single droplet

  • Chang, Daejun;Han, Sang Heon;Yang, Kyung-Won
    • Ocean Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.33-47
    • /
    • 2012
  • This study revealed the behavior of droplets formed through leak process in deep water. There was a threshold depth named the universal attraction depth (UAD). Droplets rose upward in the zone below the UAD called the rising zone, and settled down in the zone above the UAD called the settling zone. Three mass loss modes were identified and formulated: dissolution induced by mass transfer, condensation by heat transfer and phase separation by pressure decrease. The first two were active for the settling zone, and all the three were effective for the rising zone. In consequence, the life time of the droplets in the rising zone was far shorter than that of the droplets in the settling zone.

Settling Mode of the Dredged Soil (준설토의 침강형태에 관한 연구)

  • 윤상묵;장병욱;차경섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.1
    • /
    • pp.63-73
    • /
    • 2003
  • The settling of the dredged soil may vary with mineral composition, grain size distribution, initial water content and salt concentration of suspension of the site. A series of settling column test was performed to investigate the behaviour of solid suspension material from dredging and reclamation. Settling mode was divided into four types from the observation of interface and settling curves of clay minerals and marine clay samples, and the relationship charts of salt concentration and the initial water content were established to use in the dredging operation with any salt concentration. The critical initial water content which was defined as a threshold of zone settling and the consolidation settling was varied with salt concentration of water and was proportional to the plasticity of soil in sea water.

Shifts in Biochemical Environments and Subsequent Degradation of Explosive Compounds (TNT and RDX) by Starch Ball Addition in the Benthic Zone of Bench Scale Settling Basins (전분 환 투입에 의한 실험실 규모 침전지 저부에서의 생화학적 환경 변화와 화약물질(TNT 및 RDX) 분해)

  • Park, Jieun;Bae, Bumhan
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.82-93
    • /
    • 2014
  • A starch ball was devised to conveniently supply carbon source to indigenous microorganisms and to enhance biotransformation of explosive compounds(TNT and RDX) in the sediments of settling basins installed in military shooting ranges. To identify optimum dose/sediment ratio for degradation of explosives in the basin, a series of bench scale settling basin experiments were performed for 30 days while monitoring supernatant pH, DO, concentrations of nitrite, nitrate, sulfate, explosive compounds, and acute toxicity measured by bacterial luminescence. Addition of starch ball induced changes in oxidation conditions from oxic to anoxic in the benthic zone of the basin, which resulted in subsequent reductive degradation of both TNT and RDX in the liquid and solid phase of basin. However, fermentation products of excess starch, acetic acid and formic acid, caused acute toxicity in the liquid phase. The optimum ratio of starch ball/sediment for explosive compounds degradation by inducing changes in bio-geochemical environments without increase in acute toxicity, was found to be 0.009~0.017.

Evaluation of bioflocculation and settling characteristics for MLSS from a Biological Nutrient Removal Plant (생물학적 고도처리 MLSS의 생응집성 및 침강성 파악)

  • Lee, Byonghi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.219-225
    • /
    • 2008
  • Evaluating and designing secondary clarifier require to define characteristics of influent MLSS (Mixed Liquor Suspended Solids). In this study, bioflocculation and settling characteristics for MLSS from a Biological Nutrient Removal (BNR) plant located in near Seoul were measured. MLSS concentrations in bioreactor were about 2,500mg/L in summer and about 4,000mg/L in winter, respectively. Tests showed that there was not much bioflocculation occurred in secondary clarifier. Average ESS/DSS (Effluent Suspended Solids/Dispersed Suspended Solids) was 100%. From the settling tests, ZSV (Zone Settling Velocity) and settling constant (n) in Vesilind equation were estimated at different MLSS temperatures. SVI (Sludge Volume Index) and SSVI (Stirred Sludge Volume Index) were also measured at different temperatures. It was found that ZSV was positively correlated with temperature and n was inversely proportional to temperature. SVI and SSVI had very similar values at about $25^{\circ}C$ of MLSS, However, SVI had more than 2 times higher values than SSVI at below $20^{\circ}C$ of MLSS. Temperature effect must be considered to design and evaluate secondary clarifier.

Numerical Analysis of the Outlet Structure Effect on the Flow and Settling Performance of the Rectangular Clarifiers (장방형 2차 침전지 유출부의 구조가 유동 및 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Youngchul;Park, Moo Jong;Sheen, Dong-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.557-565
    • /
    • 2006
  • Proper operation of clarifier partly depends on outlet conditions. Effluent has to be uniformly withdrawn to prevent scouring of settled sludge and carry over of settling sludge from the clarifier. In this paper, 3-D numerical model was employed to analyze the flow and settling performance of the rectangular clarifier. There were two simulation conditions of which in the same clarifier, the first one was assumed to have a 11.5 meter weir length and the second has 8.5 meters. Shape, location and placement of the weir structure were different, but both of those outlets meet weir loading design criteria. Simulation results indicate that clarifier with longer weir generally gave strong and unstable currents at the mid-stream where the weir starts while in the clarifier with short and relatively simple weir, uniform and stable flow was observed in most parts of the settling zone, and especially at the weir region. These flow conditions affected settling performance. Effulent SS concentration from clarifier equipped with the long and complicated placement of weir was 24.5 mg/L, but 7.0 mg/L from the clarfieir having short weir length. From this study, it can be concluded that as reported from other studies, weir loading does not guarantee settling performance and 3-D numerical model can be a useful tool for determining and validating outlet structure.