• Title/Summary/Keyword: Set operation

Search Result 1,993, Processing Time 0.033 seconds

A Study on the Determination of Dosing Rate for the Water Treatment using Genetic-Fuzzy (유전-퍼지를 이용한 정수장 응집제 주입률 결정에 관한 연구)

  • 김용열;강이석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.7
    • /
    • pp.876-882
    • /
    • 1999
  • It is difficult to determine the feeding rate of coagulant in the water treatment process, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the genetic-fuzzy system was used in determining the feeding rate of the coagulant. The genetic algorithms are excellently robust in complex optimization problems. Since it uses randomized operators and searches for the best chromosome without auxiliary informations from a population consists of codings of parameter set. To apply this algorithms, we made the lookup table and membership function from the actual operation data of the water treatment process. We determined optimum dosages of coagulant(LAS) by the fuzzy operation, and compared it with the feeding rate of the actual operation data.

  • PDF

A Study on the Coagulant Dosage Control in the Water Treatment Using Real Number Genetic-Fuzzy (실수형 유전-퍼지를 이용한 정수장 응집제주입제어에 관한 연구)

  • Kim, Yong-Yeol;Kang, E-Sok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.312-319
    • /
    • 2004
  • The optimum dosage control is presumably the goal of every water treatment plant. However it is difficult to determine the dosage rate of coagulant, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the real number genetic-fuzzy system was used in determining the dosage rate of the coagulant. The genetic algorithms are excellently robust in complex optimization problems. Since it uses randomized operators and searches for the best chromosome without auxiliary informations from a population which consists of codings of parameter set. To apply this algorithms, we made the real number rule table and membership function from the actual operation data of the water treatment plant. We determined optimum dosages of coagulant(LAS) using the fuzzy operation and compared them with the dosage rate of the actual operation data.

A study of control system on Permanent Magnet Linear Synchronous Motor with Z-axis operation structure (Z축 운전구조를 갖는 선형 영구자석형 동기 전동기 운전제어에 관한 연구)

  • Lee C.H.;Choi C.;Park H.W.;Kim C.U.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.654-658
    • /
    • 2003
  • In this study a control system with variable gain schedule using real speed and moving direction is proposed to control a Permanent Magnet Linear Synchronous Motor (PMLSM) with Z-axis operation structure. The implementation of the controller is designed on the DSP TMS320C32 board. PMLSM is operated by using 4-point absolute positions profile with each velocity, acceleration and deceleration. The direction of the initial angle action for starting is set from the lower limit point to the upper limit point on PMLSM operation stroke. The effectiveness of a control system with variable gain schedule is demonstrated by some experimental results.

  • PDF

A Group Maintenance Model with Extended Operating Horizon (연장된 운용기간을 활용하는 그룹보전모형)

  • Yoo, Young-Kwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.89-95
    • /
    • 2017
  • This paper presents another maintenance policy for a group of units under finite operating horizon. A group of identical units are subject to random failures. Group maintenances are performed to all units together at specified intervals, and the failed units during operation are remained idle until the next group maintenance set-up. Unlike the traditional assumption of infinite operating horizon, we adopt the assumption of the finite operating horizon which reflect the rapid industrial advance and short life cycle of modern times. The units are under operation until the end of the operating horizon. Further, the operation of units are extended to the first group maintenance time after the end of the horizon. The total cost under the proposed maintenance policy is derived. The optimal group maintenance interval and the expected number of group maintenances during the horizon are found. It is shown that the proposed policy is better than the classical group maintenance policy in terms of total cost over the operating horizon. Numerical examples are presented for illustrations.

The Effects of Correct Implementation of Six Sigma Practices on Customer Focus Performance, Quality Performance and Business Performance (식스시그마의 올바른 실행이 고객관점 성과, 품질성과 및 사업성과에 미치는 영향)

  • Yoon, Jae-Hong
    • Korean Management Science Review
    • /
    • v.30 no.1
    • /
    • pp.59-72
    • /
    • 2013
  • This research has seven factors such as top management leadership, belt system operation, implementation of systematic methods, adequate project performance measurement, customer focus performance, quality performance and business performance. Those are critical to correct implementation of Six Sigma. I set seven hypotheses which represented the relationships among the seven factors, gathered questionnaires and analyzed the data. Top management leadership affected positively the adequate project performance measurement and the belt system operation, The belt system operation affected the implementation of systematic methods positively and it also affected the adequate project performance measurement. It affected positively the customer focus performance, the quality performance and the business performance, respectively.

Operation peration and Management of Irrigation System-Concept and Technology (관개조직의 유지관리)

  • Kuroda, Masaharu
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.1-7
    • /
    • 1999
  • The control system is very important for the precise operation and suitable management of irrigation system. The Japanese Society of Irrigation, Drainage and Reclamation Engineering has a committee for investigating irrigation system control. The committee is trying to set up a manual for the control system. The concept of the control system in the preparing manual will be discussed in this report.

  • PDF

The Design of A Program Counter Unit for RISC Processors (RISC 프로세서의 프로그램 카운터 부(PCU)의 설계)

  • 홍인식;임인칠
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.7
    • /
    • pp.1015-1024
    • /
    • 1990
  • This paper proposes a program counter unit(PCU) on the pipelined architecture of RISC (Reduced Instruction Set Computer) type high performance processors, PCU is used for supplying instruction addresses to memory units(Instruction Cache) efficiently. A RISC processor's PCU has to compute the instruction address within required intervals continnously. So, using the method of self-generated incrementor, is more efficient than the conventional one's using ALU or private adder. The proposed PCU is designed to have the fast +4(Byte Address) operation incrementor that has no carry propagation delay. Design specifications are taken by analyzing the whole data path operation of target processor's default and exceptional mode instructions. CMOS and wired logic circuit technologic are used in PCU for the fast operation which has small layout area and power dissipation. The schematic capture and logic, timing simulation of proposed PCU are performed on Apollo W/S using Mentor Graphics CAD tooks.

  • PDF

Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

The research between the vertical slope and the train set performance (선로의 기울기와 열차운전성능에 관한 연구)

  • Jeong Byeng-Ryul;Woo Sung-won;Park Seong-Ik
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.400-405
    • /
    • 2005
  • The vertical slope of railway track is the differences of attitude for the horizontal distances between two positions of railway. It is better to be small vertical slope for the comfortable of passengers and the operation of railway system. However, the variable vertical slope is required that the simple vertical slope causes the huge quantities of embankment and cutting, the continuous welded rail tunnels, the continuous welded rail bridges, etc,. This research is for the relation between the vertical slopes and the trainset performances. This research shows that the effective vertical slopes for the operation of railway. The velocity of car and operation time and the consumed energy was considered for each vertical slope and type of car power system. The result of suitable vertical slope from this research is to be used for the design of railway plan.

  • PDF

RADIOLOGIC STUDY ON THE POSTERIOR ASPECT OF THE MAXILLA FOLLOWING THE RADICAL OPERATION OF PARANASAL SINUSES. (상악동 근치수술후의 상악골 후연의 변화에 대한 방사선학적 연구)

  • Park No Won;You Dong Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.15 no.1
    • /
    • pp.59-66
    • /
    • 1985
  • The Purpose of this study is to detect morphological changes of the maxilla following the operation of paranasal sinuses in the orthopantomogram. 1) The measurement of the angle set up by two reference lines which represent posterior aspect of the maxilla and skull base was made. 2) The mean angle in the post-operative patients showed significantly smaller than that in the normal subjects. 3) The forms of posterior aspect of maxilla were classified into 5 types. (flat, convex, concave, uneven and obliterated.) 4) In contrast with the convex type in the majority of normal subjects, approximately half of the post-operative patients showed the concave type. 5) These results may suggest that the superior part of the posterior aspect of the maxilla tend to depress following the operation of these paranasal sinuses.

  • PDF