• Title/Summary/Keyword: Service Measurement

Search Result 1,813, Processing Time 0.029 seconds

A Survey on the status of using trichloroethylene(TCE) in Korea (트리클로로에틸렌의 유통·사용 실태조사 결과)

  • Cho, Hyung-Yoel;Cho, Sung-Hyun;Ryoo, Jang-Jin;Kim, Byung Gyu;Park, Seung-Hyun;Kang, Seong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.254-260
    • /
    • 2007
  • Trichloroethylene(TCE) is widely used as a degreasing solvent in workplaces. TCE is primarily toxic to the nervous system, however, systemic disorder like Stevens-Johnson syndrome has been recently reported in small-scale factories, where the government has had limited information of chemical use. A survey was performed to investigate the actual condition of using TCE and to provide practical information to occupational health service agencies and professionals. This survey was carried out on 103 factories out of 430 factories which were conducted periodic work environment measurement for TCE. Degreasing was the most popular reason for using TCE in Korea, which reached to 94%. TCE was also used as a solvent for rubber in the coating or molding process, and adhesives in the bonding process. Metal fabrication was the most common as 23%, followed by assembling automobile parts (17%), and machinery (12%). Workers exposed to TCE during full-shift were 52% while 48% were exposed during short period of the shift or intermittently. Manual or semi-automatic work occupied 87% while automatic work was just 13%. Though automatic work by a closed system was generally lower exposed to TCE, compared to manual work, it can cause a high exposure when the maintenance system is improper. Semi-automatic work especially like open-top degreasing process can cause a high exposure when local exhaust system with condensing and refrigerating coils in the degreaser does not work well. In conclusion, the survey showed nationwide status of TCE exposure in various aspects. It can be used to monitor workplaces and workers exposed to TCE to prevent occupational diseases.

Systematic Review of Korean Medicine-related Study on Diagnostic Tools and Pattern Identification registered of Dysmenorrhea in the Korean Journal (국내 전자저널에 수록된 월경통 평가지표 및 변증에 대한 한의학적 임상연구 고찰)

  • Kim, Jihye;Kim, Jongyeol;Jeon, Youngju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.29 no.5
    • /
    • pp.434-442
    • /
    • 2015
  • The purpose of this review was to survey the Korean Medicine related papers about women with primary dysmenorrhea in order to develop the clinical protocol of the diagnostic medical device. We searched the literature from 2000 through April 2015 using 5 online databases including Oriental Medicine Advanced Searching Integrated Sysptem (OASIS), Research Information Sharing Service (RISS), DataBase Periodical Information Academic (DBpia) and Korean Medical Database (KMBase). We selected papers to meet the following inclusion criteria: the papers involved dysmenorrhea (excluding secondary dysmenorrhea), published papers (excluding textbook, educational materials, conferences, etc.) and the papers matched search keywords or scope, but excluded papers to meet the following exclusion criteria: the duplicative papers, get out of the keywords and scope and not in english or korean language. Finally we found 17 papers and classified the papers according to the three search purposes which were diagnostic tools for evaluating the menstrual pain, dysmenorrhea' pattern identification and menstrual phase. Out of the 16 studies, 4 studies were focused on the diagnostic tools including Visual Analogue Scale (VAS), Measurement of Menstrual Pain (MMP) and etc. Other 5 studies were aimed at menstrual phase, and the other 7 studies were studied for pattern identification. The VAS has been widely used in research and in clinical practice for the detection of the menstrual pain. Treatments for patients with primary dysmenorrhea can be prescribed in consideration of their patterns of sasang constitution or body constitution as following: Qi stagnation-Blood deficiency, cold dampness, Qi deficiency-blood deficiency and liver-kidney deficiency etc. This results of research will be used as a useful material during plan a clinical study of primary dysmenorrhea and acquisition of good clinical data.

Determination of urinary cortisol : creatinine ratios by sequential thin layer chromatography and ELISA in dogs (개에서 thin layer chromatography 박층크로마토그라피 및 ELISA를 이용한 요중의 cortisol : creatinine비 측정)

  • Sohn, Dae-ho;Na, Ki-jeong;Oh, Tae-ho;Lee, Hye-sook;Han, Hong-ryul
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.5
    • /
    • pp.1006-1012
    • /
    • 1999
  • This study was conducted to evaluate the ELISA kit for measuring the level of cortisol in the urine. The CV of within-run variation and day to day variation were 0.4~2.8 and 1.8~5.7, respectively. The minimum limitation of measurement was 1ng/ml. The cross reaction was high ($CR_{50}(%)=11.4{\sim}43.2$) in prednisolone, 11-deoxycortisol, 21-deoxycortisol and predinosone. There was low and no cross reaction in other steroid. To develop the ELISA kit we measured the cortisol level in diluted urine with PBS (procedure I), extracted urine with methylene chloride (procedure II) and extracted methylene chloride-extracted urine from thin-layer chromatography (procedure III). The CV value of procedure I, II, III was 9.4~28.3%, 7.2~8.9% and 2.5~5.7%, respectively. There was significant difference between procedure I with II, and pro-cedure I with III(p < 0.01), but no difference between procedure II with III significantly(p < 0.01). The mean UCCR of urine collected through am 8 to 10 was $9.5{\pm}7.6$(0.14~28.0) in 12-month-old dog(n = 47). In this study we can measure the cortisol level in extracted urine with methylene chloride and sequential thin-layer chromatography accurately using ELISA kit.

  • PDF

Development of Walking Assistive System using Body Weight Supporting and Path Planning Strategy (인체 자중 보상 및 로봇 경로계획법을 이용한 이동형 보행 재활 시스템 개발)

  • Yu, Seung-Nam;Shon, Woong-Hee;Suh, Seung-Whan;Lee, Sang-Ho;Han, Chang-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.939-947
    • /
    • 2010
  • With the rising numbers of elderly and disabled people, the demand for welfare services using a robotic system and not involving human effort is likewise increasing. This study deals with a mobile-robot system combined with a BWS (Body Weight Support) system for gait rehabilitation. The BWS system is designed via the kinematic analysis of the robot's body-lifting characteristics and of the walking guide system that controls the total rehabilitation system integrated in the mobile robot. This mobile platform is operated by utilizing the AGV (Autonomous Guided Vehicle) driving algorithm. Especially, the method that integrates geometric path tracking and obstacle avoidance for a nonholonomic mobile robot is applied so that the system can be operated in an area where the elderly users are expected to be situated, such as in a public hospital or a rehabilitation center. The mobile robot follows the path by moving through the turning radius supplied by the pure-pursuit method which is one of the existing geometric path-tracking methods. The effectiveness of the proposed method is verified through the real experiments those are conducted for path tracking with static- and dynamic-obstacle avoidance. Finally, through the EMG (Electromyography) signal measurement of the subject, the performance of the proposed system in a real operation condition is evaluated.

High-Gain Fabry-Pérot Cavity Antenna with Planar Metamaterial Superstrate for Wibro Base Station Antennas (평판형 메타 물질로 구성된 상부 덮개를 갖는 와이브로 기지국용 고 이득 Fabry-Pérot 공진기 안테나)

  • Kim, Dong-Ho;Choi, Jae-Ick
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1367-1374
    • /
    • 2008
  • A new high-gain Fabry-$P{\acute{e}}rot$ cavity antenna for wireless broadband internet(Wibro) base station antennas, which is covered with metamaterial superstrate presenting simultaneous negative values of permittivity and permeability, is proposed. To facilitate the fabrication process using the printed circuit board(PCB) technology of today, a new planar-type metamaterial superstrate is designed, which shows negative and low positive values of a refractive index near the Wibro service frequency band. And the principle of antenna gain enhancement is analyzed from the two different view points of effectively low refractive index and of the Fabry-$P{\acute{e}}rot$ resonance condition. Single square patch antenna is used as a feeder. The separation distance is determined by considering the reflection phases of the metamaterial superstrate and the substrate satisfying Fabry-$P{\acute{e}}rot$ resonance condition, respectively. Comparison between the prediction and the measurement shows good agreement, which verifies the validity of our design approach.

Design of Multiband Repeater Antenna with Fire-Fighting Band for In-Building Mobile Communication (소방무선대역을 포함하는 인빌딩용 다중대역 중계기 안테나 설계)

  • Kim, Sung-Min;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.495-503
    • /
    • 2016
  • This paper proposes the design of multiband repeater antenna with fire-fighting band for in-building mobile communication. The proposed antenna is composed of a center monopole and 4 parasitic elements on a circular plate. In order to realize good reflection coefficients at the multiband, mutual coupling between 4 parasitic elements and center monopole antenna is considered. The important parameters such as distance between parasitic element and a center monopole, and each height of a center monopole and 4 parasitic elements are simulated to obtain good antenna characteristics at the multiband. The diameter of 4 parasitic elements and a center monopole was fixed to 10 mm for easy design and manufacturing. The measurement results of reflection coefficients, 2-D patterns and gain agreed well with their simulation ones.

Design of a Broadband Window Antenna Using a Parallel T-Matching Network (병렬 T-정합 회로를 이용한 차량 유리 부착형 광대역 안테나 설계)

  • Kim, Yoon-Geon;Kay, Young-Chul;Ji, Sung-Hwan;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.122-130
    • /
    • 2012
  • In this paper, we propose a broadband vehicle antenna that can operate at the WiBro band(2.3~2.4 GHz) for a wireless internet service. The feeding of the proposed antenna consists of two T-matching networks on both side of the polyarcylate substrate, and the two T-matching networks are connected through via holes. The designed antenna was built and installed on a rear window of a commercial sedan, and the antenna performances, such as the reflection coefficients and the radiation gain are measured in the open-sight area. The received signal strength of the designed antenna was also tested in a strong field area as well as in a weak field area. The measurement results show the matching bandwidth($S_{11}$ <10 dB) of about 300 MHz in the WiBro band and the average gain of about -5.13 dBi along the azimuth direction.

A Small Broadband Antenna for Wibro/WLAN/Mobile WiMAX (Wibro/WLAN/Mobile WiMAX용 소형 광대역 안테나)

  • Ko, Jeong-Ho;Choi, Ik-Guen
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.5
    • /
    • pp.568-575
    • /
    • 2011
  • In this paper, we propose a small broadband antenna for mobile device. The proposed antenna consists of a printed rectangular monopole antenna and a parastic element connected to ground using narrow meander line and it is designed on a FR-4 substrate that has a thickness of 0.8 mm and a dielectric constant of 4.4. The FR-4 substrate's size is 50 mm${\times}$90 mm comparable to the real mobile device. The fabricated antenna's size is 12.5 mm${\times}$10.5 mm${\times}$0.8 mm and the measurement shows -10 dB return loss bandwidth of 2,200~6,000 MHz and gains of 2.86~4.01 dBi. Accordingly, the proposed antenna can support mobile device for WiBro(2,300~2,380 MHz), WLAN(IEEE 802.11b/g/n: 2,400~2,480 MHz, IEEE 802.11a: 5,150~5,825 MHz), and mobile WiMAX(IEEE 802.16e : 2,500~2,690 MHz, 3,400~3,600 MHz) service bands.

Research about Benchmark System Design for Efficient Web Server Management (효율적인 웹 서버 관리를 위한 평가시스템 설계에 관한 연구)

  • Kim, Seok-Soo;Song, Jae-Gu
    • Convergence Security Journal
    • /
    • v.7 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • It is important to manage and correctly evaluate the performance of server in order to improve he performance of server. That is, with the aim of finding whether resources are properly utilized, it is a method to improve both software and hardware aspects. Conventional method in evaluating the server performance involved installing software between server and client and generating the load and by simulating the process, it evaluated the handing efficiency of work load generated per packet volume. Therefore, this paper aims to pro-vide precise measurement method by distinguishing the characteristics of web server and the users' usage pattern and by evaluating the work load management through applying various standards. Specially, it presents the evaluation method from web service of personal and business.

  • PDF

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.