• Title/Summary/Keyword: Server power system

Search Result 385, Processing Time 0.026 seconds

Design and Implementation of a Node Power Scheduler in Virtual Computing Lab Environment (가상 컴퓨팅 랩 환경에서 노드 전원관리 스케줄러 설계 및 구현)

  • Seo, Kyung-Seok;Lee, Bong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1827-1834
    • /
    • 2013
  • The existing PC-based desktop environment is being changed to a server-based virtual desktop environment due to various advantages such as security, mobility, and upgrade cost reduction. In this paper, a virtual computing lab service system which is applicable to the existing computer lab is designed and implemented using both an open source-based cloud computing platform and hypervisor. In addition, a node power scheduler is proposed in order to reduce power consumption in a server farm. The experimental results show that the power scheduler reduces power consumption considerably over the server farm without the power scheduler.

Development of Three-Dimensional Flow Velocity Component Measurement System with Straight-Type Five-Hole Pressure Probe Using Ch Language (Ch를 이용한 직선형 5공 압력 프로브의 3차원 유동속도 계측시스템 개발)

  • Oh, S.H.;Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • This paper shows the development process for measuring three-dimensional flow velocity components in a web-browser. The system is developed in an embeddable C/C++ interpreter Ch and Ch-CGI toolkit. The interface for the web-based measurement system consists of a set of web HTML files and Ch files for CGI. All of data in web browser are passed to Ch-CGI script to generate the output of new HTML file. PC-Server and PC-Client can submit measurement parameters and receive the text/graphical results each other. PC-Client can control the test equipment by using a parameters that received from PC-Server. It also can pass the test results between the web-based measurement system. In summary, the designed measurement system is evaluated, the outputs shown well on the web browser.

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

DOC: A Distributed Object Caching System for Information Infrastructure (분산 환경에서의 객체 캐슁)

  • 이태희;심준호;이상구
    • Proceedings of the CALSEC Conference
    • /
    • 2003.09a
    • /
    • pp.249-254
    • /
    • 2003
  • Object caching is a desirable feature to improve the both scalability and performance of distributed application systems for information infrastructure, the information management system leveraging the power of network computing. However, in order to exploit such benefits, we claim that the following problems: cache server placement, cache replacement, and cache synchronization, should be considered when designing any object cache system. We are under developing DOC: a Distributed Object Caching, as a part of building our information infrastructures. In this paper, we show how each problem is inter-related, and focus to highlight how we handle cache server deployment problem

  • PDF

Building IEC 61850 SCADA system based on TETRA (TETRA 기반 IEC 61850 SCADA 시스템 구축)

  • Song, Byung-Kwen;Jeong, Tae-Ui
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.87-94
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is the wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. IEC 61850 is the protocol proposed for SAS(Substation Automation System) of SCADA(Supervisory Control And Data Acquisition) system. In this paper, IEC 61850 Server and Client simulator are used based on Linux operating system. The multi-functional gateway, which transforms the communication based on TCP/IP between IEC 61850 Server Simulator and Client Simulator to the one based on TETRA Packet Data Service, is developed such that IEC 61850 SCADA system is constructed based on TETRA.

  • PDF

A Design of Power-saving PC System Using the IP Address Restriction (IP 주소 제한을 이용한 PC 절전 시스템의 설계)

  • Kim, Hong Yoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.2
    • /
    • pp.89-97
    • /
    • 2013
  • The green IT technology is being introduced in diverse sectors, especially in the data center and green computer sectors. Rack-type PCs, which have been developed by improving the computer hardware, are effective for data centers and large businesses, but they are not usually introduced in small organizations such as small and medium businesses and schools because they require high initial costs. Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. In this paper, a technique wherein the server has a restriction in providing the IP address to the computers that has no power-saving software is proposed, so that users will cooperate in the PC power-saving system to avoid inconvenience. In order to provide restricted IP address periodically, the server makes a request of power-saving software installation check for user's PC. Proposed technique is more effective ways to save computer energy, because it does not depend on specific systems or organizations.

A Study on Computer Center Maintenance Savings through NT Server Consolidate Virtualization (NT 서버 통합 가상화를 통한 전산센터 유지보수 절감에 대한 연구)

  • Lee, Yong-Hui;Kim, Hwan-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.11-19
    • /
    • 2014
  • In this paper, we build server consolidate virtualization focusing on NT server dilapidated and through analysis of the effect of this, has been presented the following results. First, it was possible to obtain an increase in the constant temperature constant humidity chamber efficiency by securing the upper surface space for computing data center mounted virtualization integration server servers multiple physical. Second, by the deployment of virtualization of a large server dilapidated, the introduction of new resources and the cost of maintaining computerized data center and reduce power consumption, the reduction of hardware introduction of additional due to the new server deployment it was possible to derive a cost reduction effect. We obtain the reduction of 89% and 79% compared with conventional consumption of cooling and power savings of the top surface, respectively. Integration of NT servers are virtualized can be expected to change in the Green-IT to contribute to providing the maintenance costs of computing centers in the future as well as current. Building a virtualization server integration applied in this paper can be similarly applied to the UNIX system and to integrate the server group other.

Development of Telemetering and Control system using PLC and Web (전력선통신과 인터넷을 이용한 원격제어 및 검침구현)

  • 최원호;박종연
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.4
    • /
    • pp.282-290
    • /
    • 2003
  • AMR(Automatic Meter Reading) and RC(Remote Control) System have been researched from former several decade for a various power rate system, a efficient power service and rising of personal expenses, etc. But the existing AMR and RC System have disadvantage which are complex and high cost to install an individual communication network of electricity company. This paper proposed a new type of AMR and RC System using PLC with Web. and made components for proposal system. Most customer who live in apartment have an internet cable in the Republic of Korea. Therefore there is no more installation component for communication in proposal system at the apartment, except Web server system and PLC modem. so we made the PLC modem the digital watt-hour meter with a build in PLC modem and the software on server computer for establishing the proposal system.

Development of the remote control system for Internet-based mobile robot using Embedded Linux and Qt

  • Park, Tae-Gyu;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.622-627
    • /
    • 2003
  • The existing remote control system have some inherent disadvantage of direct control in the limit range. In some special cases, for example, a power apparatus, an unmanned factory, a nuclear factory, a security management system, the tele-operation is needed to control remote robot without limit space. This field is based on the Internet communication. Because the Internet is constructed all over the world. And it is possible that we control remote mobile robot in the long distance. In this paper, we developed a remote control system. This system is divided into two primary parts. These are local site and remote site. There are the moving robot and web server in the remote site and there is the robot control device in local site. The moving robot is moved by two stepper motors and the robot control device consists of SA-1100 micro controller and embedded Linux. And this controller is an embedded system. Public personal computer which is connected the Internet is used for the web server. The web server provides the mobile robot control interface program to the remote controller and captures the image for feedback information. In the whole system, a robot control device is connected with moving robot and web server through the Internet. So the operator can control the moving robot in the distance through the Internet.

  • PDF

Rack-Level DC Power Solution for Volume Servers

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • v.32 no.6
    • /
    • pp.940-949
    • /
    • 2010
  • Rack-level DC power supply is the optimal technology for providing DC power to a volume server without any power infrastructure changes in an existing AC data center. In this paper, we propose a smartly controllable and monitorable DC rack power system. The proposed system improves power efficiency by changing the power distribution architecture of a conventional method in the rack. We developed an optimal power control method in multipower modules to provide high efficiency at low loads. In addition, the proposed system provides real-time web monitoring of the rack power and environment around a rack. In our experiments, the proposed system improved the power efficiency by over 10% compared to an AC power system providing N+1 redundant power and power monitoring.