• Title/Summary/Keyword: Series and Parallel Resonance

Search Result 39, Processing Time 0.027 seconds

Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory

  • Wu, Jian;Han, Wanqin;Chen, Tao;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.746-756
    • /
    • 2018
  • Harmonic resonance exists in grid-connected inverter systems. In order to determine the network components that contribute to harmonic resonance and the composition of the resonant circuit, sensitivity theory is applied to the resonance characteristic analysis. Based on the modal analysis, the theory of sensitivity is applied to derive a formula for determining the sensitivities of each network component parameter under a resonance circumstance that reflects the participation of the network component. The solving formula is derived for both parallel harmonic resonance and series harmonic resonance. This formula is adopted to a 4-node grid-connected test system. The analysis results reveal that for a certain frequency, the participation of parallel resonance and series resonance are not the same. Finally, experimental results demonstrate that the solving formula for sensitivity is feasible for grid-connected systems.

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

Film Bulk Acoustic Resonator(FBAR) using Bragg Reflector for IMT-2000 Bandpass Filter (Bragg 반사층을 이용한 IMT-2000 대역통과필터용 체적 탄성파 공진기)

  • 김상희;김종헌;박희대;이시형;이전국
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.377-382
    • /
    • 2000
  • Film bulk acoustic resonator (FBAR) using AIN reactively sputtered at room temperature was fabricated. The FBAR is composed of a piezoelectric aluminium nitride thin film, top electrode of Al and bottom electrode of Au connected by a short (200${\mu}{\textrm}{m}$) transmission line on both sides and reflector layers of SiO$_2$- W Pair. The active areas of Al and Au were patterned using 150${\mu}{\textrm}{m}$ diameter shadow mask. The series resonance frequency (fs) and the parallel resonance frequency (fp) were measured at 1.976 GHz and 2.005 GHz, respectively. The minimum insertion loss and return loss were 6.1 dB and 37.19 dB, and the quality factor (Q) was 4261.

  • PDF

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Series-parallel resonant converter using a contactless power supply for the efficiency improvement (효율 개선을 위한 직${\cdot}$병렬 공진컨버터 적용 비접촉 전원)

  • Kong Y.S.;Lee H.K.;Kim E.S.;Cho J.G.;Kim J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • To improve the efficiency characteristics in the resonant converter using the contact-less power supply with the large air-gap and the long primary winding, this paper suggests the three-level series-parallel resonant converter(SPRC). The voltage gain characteristics of the proposed converter have the unit gain in a resonance frequency point of the series and parallel, and input voltage and current in the primary of SPRC are always In phase for the all equivalent load resistance because of the parallel resonant tank of the high impedance. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental prototype.

  • PDF

Electrical Properties of a Laminated Piezoelectric Transformer with the Divided Electrodes (전극 분할 적층형 압전변압기의 전기적 특성)

  • Lee, Yong-Kuk;Lee, Sang-Cheal;Hur, Doo-Oh;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1140-1142
    • /
    • 1995
  • The transformer is fabricated with two piezoelectric vibrator with the divided electrodes and adhesive insulator. We applied the electric input to the driving vibrator in parallel and connect the output voltage to the generating vibrator in series to the resistor load near its fundamental resonance frequency. Then we investigate output voltage in series twice as large as in parallal. Moreover we investigate the load characteristics at resonance frequencies under various resistor and the frequency characteristics near the resonance frequency under no load. Its equvalent circuit is derived from the Mason's model of a thickness-driven piezelectric vibrator. By its equevalent circuit, symbolic expressions for input impedances, voltage ratios, resonance frequencies, and bandwidths have been derived. The values calculated from those symbolic exprssions are shown to agree well with the measurement values.

  • PDF

Analysis on the cascade high power piezoelectric ultrasonic transducers

  • Lin, Shuyu;Xu, Jie
    • Smart Structures and Systems
    • /
    • v.21 no.2
    • /
    • pp.151-161
    • /
    • 2018
  • A new type of cascade sandwiched piezoelectric ultrasonic transducer is presented and studied. The cascade transducer is composed of two traditional longitudinally sandwiched piezoelectric transducers, which are connected together in series mechanically and in parallel electrically. Based on the analytical method, the electromechanical equivalent circuit of the cascade transducer is derived and the resonance/anti-resonance frequency equations are obtained. The impedance characteristics and the vibrational modes of the transducer are analyzed. By means of numerical method, the dependency of the resonance/anti-resonance frequency and the effective electromechanical coupling coefficient on the geometrical dimensions of the cascade transducer are studied and some interesting conclusions are obtained. Two prototypes of the cascade transducers are designed and made; the resonance/anti-resonance frequency is measured. It is shown that the analytical resonance/anti-resonance frequencies are in good agreement with the experimental results. It is expected that this kind of cascade transducer can be used in large power and high intensity ultrasonic applications, such as ultrasonic liquid processing, ultrasonic metal machining and ultrasonic welding and soldering.

Analysis for Electrical Stress of Power Capacitor (전력용 커패시터의 전기적 스트레스 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.370-376
    • /
    • 2008
  • Power capacitors is widely used for power factor correction and component of passive filter in the user power systems. Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current. There are series resonance and parallel resonance when capacitors are applied in the user electrical application. If this harmonic component matches resonance, voltage and current is magnified and has severely an influences on capacitor. This paper purposes a new method for the magnitude of voltage and current by the frequency scan analysis without equivalent circuit for the actual circuit at the resonance condition.

Frequency Follow-up Control System of Resonant Load MOSFET Inverter using PLL (PLL을 이용한 공진부하 MOSFET 인버어터의 주파수 추종제어계)

  • Kim, Joon-Hong;Joong-Hwan kim
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.7
    • /
    • pp.272-277
    • /
    • 1986
  • The system that follows to the resonance frequency of high frequency MOSFET inverter and varies according to the changes of load characteristics is proposed. Also we suggested a method how to select the resonant load type between series and parallel circuit for a given inverter type. It leads to the conclusion that in the case of high impedance loads, parallel resonant circuits are preferable, on the other hand, for low impedance loads, series resonant circuits are more preferable. For frequency tracking, a PLL circuit is used as main control element to detect the phase difference of current and voltage of load. The realized apparatus composed of control circuit and voltage type full-bridged MOSFET elements as main parts of inverter. A stable frequency follow-up characteristics are obtained for 1.2MHz, 1.5KW high frequency output and power is always supplied to the load with unity power factor.

  • PDF

Analysis of Forced Resonance Characteristics of Electrically Small Dipole Antennas and Its Application to Measurements of Unknown Frequency (전기적 소형다이폴 안테나의 강제 공진특성 해석과 주파수 측정에의 응용 가능성 연구)

  • Ki-Chai Kim
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.3
    • /
    • pp.264-272
    • /
    • 1997
  • This paper presents the analysis of forced resonance characteristics of electrically small dipole antenna loaded with external element and its application to measuring unknown frequencies. The method of moments with Galerkin's procedure is used to determine the current distribution of the antenna. To derive the determinantal equation of resonance lengths at a given frequency, small antennas with the reactance loaded can be treated as a two-port network. Numerical results show that the forced resonance of the electrically small dipole antenna loaded with reactance can be easily obtained by controlling the reactance for the series resonance as well as for the parallel resonance. It is demonstrated that the forced resonance characteristics can also be applied to the measurement of unknown frequencies.

  • PDF