• Title/Summary/Keyword: Series System

Search Result 5,753, Processing Time 0.035 seconds

Joint reliability importance of series-parallel systems

  • Dewan, I.;Jain, K.
    • International Journal of Reliability and Applications
    • /
    • v.12 no.2
    • /
    • pp.103-116
    • /
    • 2011
  • A series-parallel system with independent but non-identical components is considered. The expressions have been derived for the joint reliability importance (JRI) of m (${\geq}2$) components, chosen from a series-parallel system. JRIs of components of two different series-parallel systems are studied analytically and graphically.

  • PDF

Frequency Controlled Series Resonant Converter System for Power Supply of Communication Station (통신 기지국 전원용 주파수 제어 직렬 공진형 컨버터 시스템)

  • 지준근;임영하
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.323-328
    • /
    • 2003
  • In this paper new control strategy of series resonant converter system for power supply of communication station is suggested. Frequency controlled series resonant converter system is robust to load variations because it is POSR(Parallel Output Series Resonant: POSR) type. And it provides stable output voltage by changing switching frequency to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using ACSL(Advanced Continuous Simulation Langage) and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF

The optimal parameters in series-series counterflow chillers system within air conditioning (공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수)

  • Phu, Nguyen Minh;Hung, Bui Ngoc;Lee, Geun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

Resonant Converter System for Control Power Supply (제어용 전원으로 사용가능한 공진형 컨버터 시스템)

  • Ji Jun-Keun;Lim Young-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.69-72
    • /
    • 2003
  • In this paper new control strategy of series resonant converter system for control power supply is suggested. Frequency controlled series resonant converter system is robust to load variations because it is POSR(parallel output series resonant) type. And it provides stable output voltage by changing switching frequency to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using ACSL(Advanced Continuous Simulation Language) and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF

ESTIMATION OF SYSTEM RELIABLITY FOR REDUNDANT STRESS-STRENGTH MODEL

  • Choi, In-Kyeong
    • Journal of applied mathematics & informatics
    • /
    • v.5 no.2
    • /
    • pp.277-284
    • /
    • 1998
  • The reliability and an estimate for it are derived for series-parallel and parallel-deries stress-strength model under assumption that all components are subjected to a common stress. We also obtain the asymptotic normal distribution of the estimate.

A Study on the series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire System (3상 3선식 시스템의 고조파 저감을 위한 직렬형 능동전력필터에 관한 연구)

  • 한윤석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.735-738
    • /
    • 2000
  • In this paper we propose a series active power filter and a simple calculation method acquiring the reference voltage. A series active power filter is suitable to suppress harmonics produced by voltage type harmonic source such as a diode rectifier with filter capacitor on the DC side The proposed series active power filter system is applied to 3-phase 3-wire power system including the voltage type harmonic source. Experimental result obtained from a laboratory model are shown to verify the viability and effectiveness of the proposed system.

  • PDF

Hybrid Series Active Power filter Based on Performance Function Theory for 3-Phase 4-wire System (성능함수제어 알고리즘을 이용한 3상 4선식 하이브리드형 직렬능동전력필터)

  • Kim, Jin-Sun;Shin, Jae-Hwa;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1096-1098
    • /
    • 2003
  • In this paper, the control algorithm and control methods for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and odd multiples of $3^{rd}$($9^{th}$, $15^{th}$, etc.) are termed as triple and zero sequence components that do not cancel each other in the system neutral. As a result, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control scheme for a series hybrid active system. This series active power filter acts not only as a harmonic compensator but also as a harmonic isolator. Hence the required rating of the series active filter is much smaller than that of a conventional shunt active filter. However, the performance of the combined system is greatly influenced by the filtering algorithm employed in the active power filter. This paper proposes a series active power filter scheme based on performance function. Some experiments was executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

  • PDF

A study for setting prior allocation of redundancy in parallel series system (체계중복 설정문제에 있어서 Redundancy 우선배치에 관한 연구)

  • 조남호
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.9 no.14
    • /
    • pp.45-48
    • /
    • 1986
  • This paper studies reliability growth model in redundancy allocation of Parallel-series system in which several series system is linked parallelly, The model is generalized by system redundancy of sub-system that have components redundancy. The stage of components in each sub-system is established differently. At the same time by assigned the different number of constraints to the sub-system, this paper deals with rather practical reliability growth model.

  • PDF

A Simplified Series-Parallel Structure for the RPPT (Regulated Peak Power Tracking) system (저궤도 인공위성용 Regulated Peak Power Tracking(RPPT) 시스템을 위한 단순화된 직-병렬 구조)

  • Yang, Jeong-Hwan;Bae, Hyun-Su;Lee, Jea-Ho;Cho, Bo-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.110-118
    • /
    • 2008
  • The regulated peak power tracking (RPPT) systems such as the series structure and the parallel structure are commonly used in the satellite space power system. However, this structure processes the solar array power to the load through two regulators during one orbit cycle, which reduces the energy transfer efficiency. The series-parallel structure for the RPPT system can improve the power conversion efficiency, but an additional regulator increases the cost, size and weight of the system. In this paper, a simplified series-parallel space power system that consists of two regulators is proposed. The proposed system has the similar energy transfer efficiency with the series-parallel structure by adding one switch to the series structure, which reduces the cost, size and the weight. The large signal stability analyses is provided to understand the four main modes of system operation. In order to compare the energy efficiency with a series structure, the simulation is performed. The experimental verifications are performed using a prototype hardware with TMS320F2812 DSP and 200W solar arrays.

Research on Development of SMPS used in a Base Station for Mobile Communication (이동통신 기지국용 SMPS 개발 연구)

  • Ji Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.3
    • /
    • pp.278-284
    • /
    • 2005
  • In this paper, phase controlled series resonant converter (PCSRC) system for power supply of communication station is suggested. PCSRC system is robust to load variations because it is POSR (parallel output series resonant) type. And it provides stable output voltage by changing phase of MOSFET switches to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using PSIM and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF