• Title/Summary/Keyword: Sequential injection

Search Result 86, Processing Time 0.029 seconds

The Actual Wearing Condition for the Uniform of Pediatric Inpatient (소아환자복의 착의실태에 관한 연구)

  • Kim, Mi Sung;Lee, Jeong Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.11
    • /
    • pp.1197-1207
    • /
    • 2012
  • This study provides information for the design of pediatric inpatient uniforms with functionality and aesthetic beauty through a questionnaire-survey of the conditions of providing, wearing, preferences and improvement requirements for pediatric inpatient uniforms. As a result of the survey, intravenous injections were mostly given on the back of the hand, and the method of changing uniforms after intravenous injections was (in most cases) to pass the injection bottle through a sleeve or pant leg while the needle is inserted. The respondents answered that the sleeve length and pant length did not match. As a result of the preference of the pediatric inpatient design survey, respondents indicated they preferred pajama type, yellow color and medium size animal patterns. A similar ratio of set-in and raglan with no collar but with 3/4 length sleeve of round neck, front end, sleeve top opening, button closing and two pockets were preferred for shirts; however, a 3/4 length with rubber string on the waist, no opening and inner opening were preferred at the same ratio for pants. As for the method to adjust the length to assign functionality to pediatric inpatient uniforms, the most preferred sleeve was a roll-up sleeve with a strap and the most preferred pants were length adjusted pants that used a strap for both shirts and pants with a both sides strap. In addition, the majority of the respondents answered that a hand wrapper that protects the injection location during intravenous injections needs be developed. As for the development type, a half glove type and glove type were preferred in sequential order.

Effects of Aspirin and Furosemide on Plasma Aldosterone Level in Rabbits (토끼의 혈장내 Aldosterone 농도에 미치는 Aspirin과 Furosemide의 영향)

  • Suh, Y.J.;Lee, K.H.;Kim, O.N.;Lee, S.B.;Cho, K.C.
    • The Korean Journal of Pharmacology
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 1984
  • It has been generally recognized that the secretion of aldosterone is mainly regulated by angiotensin II in animals and humans, however, potassium and ACTH are also proposed as other humoral factors involved in the aldosterone secretory process. Recently, stress, anesthesia, adrenergic stimulation, low sodium intake or water deprivation stimulate plasma renin activity, while high sodium intake and deoxycorticosteroid have been reported to cause suppression of renin activity in animals. It seems that overall response of aldosterone secretory mechanisms reflects complex interactions both intrarenal and extrarenal components. Furosemide has been widely used to investigate the control of renin secretion by the kidney, and the relationship between diuretics and the disposition of endogenous aldosterone were reported (Oh, 1984). The sequential with 10 min interval samples of plasma were collected following administration of furosemide(1 mg/kg), aspirin(10 mg/kg), respectively. And also similar experiment was performed in the propranolol (10 mg/kg) pretreated rabbits. The results were as follows : 1) The concentration of plasma aldosterone was average of $426.I{\sim}485.5pg/ml$ in normal rabbits. Plasma concentrations of aldosterone rised significantly after injection of furosemide during 50 min, and the rise of plasma aldosterone was blocked by the propranolol pretreatment 2) Significant fall in the plasma level of aldosterone after injection of aspirin was noted. This result indicates that the increased secretion of aldosterone induced by furosemide administration is mediated through ${\beta}-receptors$, and the possible role of prostaglandin is substantiated.

  • PDF

Solution processed organic photodetector utilizing an interdiffused polymer/fullerene bilayer

  • Shafian, Shafidah;Jang, Yoonhee;Kim, Kyungkon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.348-348
    • /
    • 2016
  • Low dark current (off-current) and high photo current are both essential for a solution processed organic photodetector (OPD) to achieve high photo-responsivity. Currently, most OPDs utilize a bulk heterojunction (BHJ) photo-active layer that is prepared by the one-step deposition of a polymer:fullerene blend solution. However, the BHJ structure is the main cause of the high dark current in solution processed OPDs. It is revealed that the detectivity and spectral responsivity of the OPD can be improved by utilizing a photo-active layer consisting of an interdiffused polymer/fullerene bilayer (ID-BL). This ID-BL is prepared by the sequential solution deposition (SqD) of poly(3-hexylthiophene) (P3HT) and [6,6] phenyl C61 butyric acid methyl ester (PCBM) solutions. The ID-BL OPD is found to prevent undesirable electron injection from the hole collecting electrode to the ID-BL photo-active layer resulting in a reduced dark current in the ID-BL OPD. Based on dark current and external quantum efficiency (EQE) analysis, the detectivity of the ID-BL OPD is determined to be $7.60{\times}1011$ Jones at 620 nm. This value is 3.4 times higher than that of BHJ OPDs. Furthermore, compared to BHJ OPDs, the ID-BL OPD exhibited a more consistent spectral response in the range of 400 - 660 nm.

  • PDF

A Study on the Mixing Characteristics in Complex Turbulent Flow by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 복잡 난류유동장의 혼합특성에 관한 연구)

  • Kim, Kyung-Chun;Jeong, Eun-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.542-547
    • /
    • 2001
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera can be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration in each region after the dye infusion reflects the large scale mixing while the followed slow decay reveals the small scale mixing. The temporal change of concentration probability functions conjectures the two sequential processes in the batch type mixing. An inactive column of water existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

  • PDF

A Study on the Mixing Characteristics in a Rushton Turbine Reactor by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 러쉬톤 터빈 교반기의 혼합특성에 관한 연구)

  • Jeong, Eun-Ho;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1145-1152
    • /
    • 2002
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields was obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera could be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter. height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration after the dye infusion reflects the large scale turbulent mixing while the fellowed slow decay reveals the small scale molecular mixing. The temporal change of concentration variance field conjectures the two sequential processes for the batch type mixing. An inactive column of water is existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

Geometric distortion correction of fluorescein ocular fundus photographs (형광 안저 사진의 기하 왜곡 교정)

  • 권갑현;하영호;김수중
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.183-192
    • /
    • 1991
  • Ophthalmoscopy following the intravenous injection of fluorescein has gained great diagnostic importance in ophthalmology. This technique provides sequential evaluation of the anatomic and physiologic status of the choroidal and retinal vasculature. In order to detect the changes between fluorescein ocular fundus image frames, the direct subtraction of the two frames is inadequate because of geometric distortions and background gray level differences in two images. In this study, a scheme for the correction of the geometric distortions is proposed. Precise control point coordinate values for transformation functions are manually determined after the process including a series of blood vessel detection and thinning, and one frame is mapped to another, and then a geometric distortion corrected image is obtained. When the corrected image is used in interframe change detections, a sucessful result is ensured.

  • PDF

Isolation and Characterization of Mucinase Complex Secreted from Vibrio parahaemolyticus

  • Jun, In-Joon;Kim, Yoon-Hee;Kim, Min-Jeong;Hwang, Ho-Soon;Lee, Tae-Ho;Cha, Jae-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.5
    • /
    • pp.731-737
    • /
    • 2003
  • Mucinase complex from V. parahaemolyticus ATCC 17802 was purified 6-fold with 0.4% yield by two sequential steps of Q-Sepharose and Superdex 200HR column chromatographies. Partially purified mucinase complex showed at least 8 times higher mucin-degrading activity than the culture filtrates. The mucinase complex also showed gelatin-and-casein-hydrolyzing activities, which demonstrates that the protein is a complex compound containing several proteases. The optimum pH and temperature of partially purified mucinase complex for mucin degradation was 8.0 and $35^{\circ}C$, respectively. The partially purified mucinase complex showed high cytotoxic activity on vero cells when examined by MTT assay and microscopic observations. Cytotoxicity was significantly increased in proportion to the concentration of the mucinase complex. Mouse experiments revealed that the jejunum, ileum. and large intestinal tissues were damaged by the injection of the mucinase complex. In particular, the reduction of the goblet cells in the large intestine was remarkable. Collectively, these data suggest that the mucinase complex partially purified from V. parahaemolyticus ATCC 17802 contributes to the adhesion and invasion of V. parahaemolyticus into the host intestinal tract.

A Study on the Failure Detection and Validation of Pressurizer Level Signal in Nuclear Power Plant (원전 가압기수위신호 고장검출 및 검증에 관한연구)

  • Oh, S.H.;Kim, D.I.;Zoo, O.P.;Chung, Y.H.;Lim, C.H.;Yun, W.Y.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.175-177
    • /
    • 1995
  • The sensor signal validation and failure detection system must be able to detect, isolate, and identify sensor degradation as well as provide a reconstruction of the measurements. In this study, this is accomplished by combining the neural network, the Generalized Consistency Checking(GCC), and the Sequential Probability Ratio Test(SPRT) method in a decision estimator module. The GCC method is a computationally efficient system for redundant sensors, while the SPRT provides the ability to make decisions based on the degradation history of a sensor. The methodology is also extended to the detection of noise degradation. The acceptability of the proposed method is demonstration by using the simulation data in safety injection accident of nuclear power plants. The results show that the signal validation and sensor failure detection system is able to detect and isolate a bias failure and noise type failures under transient conditions. And also, the system is able to provide the validated signal by reconstructing the measurement signals in the failure conditions considered.

  • PDF

Changes of spontaneous pancreatic exocrine secretion during the estrous cycle in rats (흰쥐에서 발정주기에 따른 자발적인 췌장외분비의 변화)

  • Park, Hyung-seo;Lee, Tae-im;Kim, Se-hoon;Park, Hyoung-jin;yang, Il-suk
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.4
    • /
    • pp.677-681
    • /
    • 2000
  • Since the role of female sexual hormones on pancreatic exocrine secretion was not fully understood, this study was investigated to clarify the difference of spontaneous pancreatic exocrine responses during the estrous cycle and the roles of ovarian hormones on pancreatic exocrine secretion in the anesthetized female rats. Pancreatic juice was collected from the sequential 15-min samples, and then fluid and protein secretion were measured from the collected samples. The stages of estrous cycle were defined by staining the vaginal smear. The spontaneous pancreatic fluid and protein secretion were significantly increased during the diestrus stage compare to the corresponding value during the estrus stage. In the ovariectomized rat, spontaneous pancreatic exocrine secretion was significantly decreased compare to the value of female rat during the diestrus stage and was restored by subcutaneous injection of progesterone (50 mg/kg). This results suggest that the spontaneous pancreatic exocrine secretion of female rat is fluctuated according to the estrous cycle and progesterone released from ovary could stimulate the spontaneous pancreatic exocrine secretion of female rat.

  • PDF

Thioacetic-Acid Capped PbS Quantum Dot Solids Exhibiting Thermally Activated Charge Hopping Transport

  • Dao, Tung Duy;Hafez, Mahmoud Elsayed;Beloborodov, I.S.;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.457-465
    • /
    • 2014
  • Size-controlled lead sulfide (PbS) quantum dots were synthesized by the typical hot injection method using oleic acid (OA) as the stabilizing agent. Subsequently, the ligand exchange reaction between OA and thioacetic acid (TAA) was employed to obtain TAA-capped PbS quantum dots (PbS-TAA QDs). The condensation reaction of the TAA ligands on the surfaces of the QDs enhanced the conductivity of the PbS-TAA QDs thin films by about 2-4 orders of magnitude, as compared with that of the PbS-OA QDs thin films. The electron transport mechanism of the PbS-TAA QDs thin films was investigated by current-voltage (I-V) measurements at different temperatures in the range of 293 K-473 K. We found that the charge transport was due to sequential tunneling of charge carriers via the QDs, resulting in the thermally activated hopping process of Arrhenius behavior.