• Title/Summary/Keyword: Sequence images

Search Result 583, Processing Time 0.031 seconds

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Identification of Quaternary Faults and shallow gas pockets through high-resolution reprocessing in the East Sea, Korea (탄성파 자료 고해상도 재처리를 통한 동해해역의 제4기 단층 및 천부 가스 인지)

  • Jeong, Mi Suk;Kim, Gi Yeong;Heo, Sik;Kim, Han Jun
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.39-44
    • /
    • 1999
  • High-resolution images are drawn from existing seismic data which were originally obtained by Korea Ocean Research & Development Institute (KORDI) during 1994-1997 for deep seismic studies on the East Sea of Korea. These images are analyzed for mapping Quaternary faults and near-bottom gas pockets. First 12 channels are selected from shot gathers for reprocessing. The processing sequence adopted for high-resolution seismic images comprises data copy, trace editing, true amplitude recovery, common-midpoint sorting, initial muting, prestack deconvolution, bandpass filtering, stacking, highpass filtering, poststack deconvolution, f-x migration, and automatic gain control (AGC). Among these processing steps, predictive deconvolution, highpass filtering, and short window AGC are the most significant in enhancement of resolution. More than 200 Quaternanry faults are interpreted on the migrated sections in the shallow depths beneath the seafloor. Although numerous faults are found mostly at the western continental slope and boundaries of the Ulleung Basin, significant amount of the faults are also indicated within the basin. Many of these faults are believed to be formed with reactivation of basement, from geotectonic activities including volcanism, and often originated in Tertiary, indicating that the tectonic regime of the East Sea might be unstable. Existence of shallow gas pockets casts real hazardous warnings to deep-sea drillings and/or to underwater constructions such as inter-island cables and gas pipelines. On the other hand, discovery of these gas pockets heightens the interests in developing natural resources in the East Sea. Reprocessed seismic sections, however, show no typical seismic characteristics for gas hydrates such as bottom-simulating reflectors in the western continental slope and ocean floor.

  • PDF

MR T2 Map Technique: How to Assess Changes in Cartilage of Patients with Osteoarthritis of the Knee (MR T2 Map 기법을 이용한 슬관절염 환자의 연골 변화 평가)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.298-307
    • /
    • 2009
  • By using the MR T2 map technique, this study intends, first, to measure the change of T2 values of cartilage between healthy people and patients with osteoarthritis and, second, to assess the form and the damage of cartilage in the knee-joint, through which this study would consider the utility of the T2 map technique. Thirty healthy people were selected based on their clinical history and current status and another thirty patients with osteoarthritis of the knee who were screened by simple X-ray from November 2007 to December 2008 were selected. Their T2 Spin Echo (SE hereafter) images for the cartilage of the knee joint were collected by using the T2 SE sequence, one of the multi-echo methods (TR: 1,000 ms; TE values: 6.5, 13, 19.5, 26, 32.5. 40, 45.5, 52). Based on these images, the changes in the signal intensity (SI hereafter) for each section of the cartilage of the knee joint were measured, which yielded average values of T2 through the Origin 7.0 Professional (Northampton, MA 01060 USA). With these T2s, the independent samples T-test was performed by SPSS Window version 12.0 to run the quantitative analysis and to test the statistical significance between the healthy group and the patient group. Closely looking at T2 values for each anterior and lateral articular cartilage of the sagittal plane and the coronal plane, in the sagittal plane, the average T2 of the femoral cartilage in the patient group with arthritis of the knee ($42.22{\pm}2.91$) was higher than the average T2 of the healthy group ($36.26{\pm}5.01$). Also, the average T2 of the tibial cartilage in the patient group ($43.83{\pm}1.43$) was higher than the average T2 in the healthy group ($36.45{\pm}3.15$). In the case of the coronal plane, the average T2 of the medial femoral cartilage in the patient group ($45.65{\pm}7.10$) was higher than the healthy group ($36.49{\pm}8.41$) and so did the average T2 of the anterior tibial cartilage (i.e., $44.46{\pm}3.44$ for the patient group vs. $37.61{\pm}1.97$ for the healthy group). As for the lateral femoral cartilage in the coronal plane, the patient group displayed the higher T2 ($43.41{\pm}4.99$) than the healthy group did ($37.64{\pm}4.02$) and this tendency was similar in the lateral tibial cartilage (i.e., $43.78{\pm}8.08$ for the patient group vs. $36.62{\pm}7.81$ for the healthy group). Along with the morphological MR imaging technique previously used, the T2 map technique seems to help patients with cartilage problems, in particular, those with the arthritis of the knee for early diagnosis by quantitatively analyzing the structural and functional changes of the cartilage.

  • PDF

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF

A Study of Optimal SOAmin for Motor and Language Tasks in Event-related fMRI using Stochastic Design (통계학적 자극설계를 이용한 Event-related fMRl에서 운동과 언어과제의 최적 SOAmin에 대한 연구)

  • 문찬홍;유재욱;나동규;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.28-34
    • /
    • 2002
  • Purpose : The minimum stimulus onset asynchronoy(SOAmin) is one of important experimental parameters for an event-related fMRI experiment designed with the stochastic stimulus. In this study, the most efficient SOAmin is explored for the stronger activation in motor and language tasks with the stimulus designed stochastically. Materials and methods : The event-related fMRI during motor and language tasks were obtained in four normal right-handed subjects. EPI-BOLD sequence is used at 1.5Tesla MR system for the acquisition of event-related fMRI. For each task the subjects are responded for the stimulus' with 2, 3, 4, and 6 seconds SOAmin. The obtained images are processed with SPM99, and the p value is set as 0.05 for the significant activation detection. The Z value and the number of activated pixels are compared for each task. Results : For the motor task, the primary and supplementary motor areas are activated, and for the language task the consistent activated signals are detected in the Broca's. The activated signal is to be stronger for the shorter SOAmin for both motor and language tasks. At primary motor area, the activated signals is the strongest for 3 seconds SOAmin and for the supplementary motor area the result with 2 seconds SOAmin shows the strongest activation. And the result of language task shows the strongest activation at the 2 seconds SOAmin. Conclusion : In the event-related fMRI of motor and language tasks with the stochastically designed stimulus, the 2 or 3 seconds SOAmin is efficient for more activated and clustered activation.

  • PDF

Efficient Algorithms for Motion Parameter Estimation in Object-Oriented Analysis-Synthesis Coding (객체지향 분석-함성 부호화를 위한 효율적 움직임 파라미터 추정 알고리듬)

  • Lee Chang Bum;Park Rae-Hong
    • The KIPS Transactions:PartB
    • /
    • v.11B no.6
    • /
    • pp.653-660
    • /
    • 2004
  • Object-oriented analysis-synthesis coding (OOASC) subdivides each image of a sequence into a number of moving objects and estimates and compensates the motion of each object. It employs a motion parameter technique for estimating motion information of each object. The motion parameter technique employing gradient operators requires a high computational load. The main objective of this paper is to present efficient motion parameter estimation techniques using the hierarchical structure in object-oriented analysis-synthesis coding. In order to achieve this goal, this paper proposes two algorithms : hybrid motion parameter estimation method (HMPEM) and adaptive motion parameter estimation method (AMPEM) using the hierarchical structure. HMPEM uses the proposed hierarchical structure, in which six or eight motion parameters are estimated by a parameter verification process in a low-resolution image, whose size is equal to one fourth of that of an original image. AMPEM uses the same hierarchical structure with the motion detection criterion that measures the amount of motion based on the temporal co-occurrence matrices for adaptive estimation of the motion parameters. This method is fast and easily implemented using parallel processing techniques. Theoretical analysis and computer simulation show that the peak signal to noise ratio (PSNR) of the image reconstructed by the proposed method lies between those of images reconstructed by the conventional 6- and 8-parameter estimation methods with a greatly reduced computational load by a factor of about four.

Comparison of Diagnostic Accuracy of Three-Dimensional MR Cholangiopanceatography and ERCP in Various Extrahepatic Biliary Lesions (여러 간외담도 질환에서 삼차원적 자기공명 췌담관 조영술과 내시경적 역행성 췌담관 조영술과의 비교: 진단적 정확성을 중심으로)

  • 김경숙;이문규;김명환;이승규;김표년;오용호
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.148-153
    • /
    • 1997
  • Purpose: To evaluate the diagnostic role of a three-dimensional MR cholangiopancreatography (MRCP) over endoscopic retrograde cholangio-pancreatography (ERCP) in various extrah-epatic biliary disease. Materials and Methods: MRCP and ERCP were performed in 45 consecutive patients with suspected extrahepatic biliary diseases. MRCP was obtained using a reverse fast imaging with a steady-state free precession (reverse FISP: PSIF) sequence, and then images were reconstructed by standard MIP algorithm. The predictability of biliary dilatation and level of obstruction of MRCP was evaluated using ERCP as a gold standard. The accuracy distinguishing malignant from benign lesions, and overall diagnostic accuracy were compared between MRCP and ERCP. Results: The sensitivity, specificity and accuracy of MRCP in predicting biliary dilatation were 94.6%, 75.0% and 91.1%, respectively. The level of obstruction was accurate in 87.0% with MRCP. The sensitivity, specificity and accuracy of MRCP and ERCP in distinguishing malignant from benign lesions were 76.2%, 87.5% and 82.2% and 71.4%, 83.3% and 77.8%, respectively. The overall diagnostic accuracy was 60.0% with MRCP and 55.6% with ERCP. Conclusion: 3D MRCP shows a good diagnostic value compared to that of ERCP, and can replace a ERCP.

  • PDF

An Algorithm for Spot Addressing in Microarray using Regular Grid Structure Searching (균일 격자 구조 탐색을 이용한 마이크로어레이 반점 주소 결정 알고리즘)

  • 진희정;조환규
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.9
    • /
    • pp.514-526
    • /
    • 2004
  • Microarray is a new technique for gene expression experiment, which has gained biologist's attention for recent years. This technology enables us to obtain hundreds and thousands of expression of gene or genotype at once using microarray Since it requires manual work to analyze patterns of gene expression, we want to develop an effective and automated tools to analyze microarray image. However it is difficult to analyze DNA chip images automatically due to several problems such as the variation of spot position, the irregularity of spot shape and size, and sample contamination. Especially, one of the most difficult problems in microarray analysis is the block and spot addressing, which is performed by manual or semi automated work in all the commercial tools. In this paper we propose a new algorithm to address the position of spot and block using a new concept of regular structure grid searching. In our algorithm, first we construct maximal I-regular sequences from the set of input points. Secondly we calculate the rotational angle and unit distance. Finally, we construct I-regularity graph by allowing pseudo points and then we compute the spot/block address using this graph. Experiment results showed that our algorithm is highly robust and reliable. Supplement information is available on http://jade.cs.pusan.ac.kr/~autogrid.

Noise Control Boundary Image Matching Using Time-Series Moving Average Transform (시계열 이동평균 변환을 이용한 노이즈 제어 윤곽선 이미지 매칭)

  • Kim, Bum-Soo;Moon, Yang-Sae;Kim, Jin-Ho
    • Journal of KIISE:Databases
    • /
    • v.36 no.4
    • /
    • pp.327-340
    • /
    • 2009
  • To achieve the noise reduction effect in boundary image matching, we use the moving average transform of time-series matching. Our motivation is based on an intuition that using the moving average transform we may exploit the noise reduction effect in boundary image matching as in time-series matching. To confirm this simple intuition, we first propose $\kappa$-order image matching, which applies the moving average transform to boundary image matching. A boundary image can be represented as a sequence in the time-series domain, and our $\kappa$-order image matching identifies similar images in this time-series domain by comparing the $\kappa$-moving average transformed sequences. Next, we propose an index-based matching method that efficiently performs $\kappa$-order image matching on a large volume of image databases, and formally prove the correctness of the index-based method. Moreover, we formally analyze the relationship between an order $\kappa$ and its matching result, and present a systematic way of controlling the noise reduction effect by changing the order $\kappa$. Experimental results show that our $\kappa$-order image matching exploits the noise reduction effect, and our index-based matching method outperforms the sequential scan by one or two orders of magnitude.

Consideration of Metaphors Appeared on Shaun Tan's 3D Short Animation, (숀 탠 (Shaun Tan)의 3D 애니메이션 에 나타난 은유적 표현에 대한 고찰)

  • Jang, Eun-Young
    • Cartoon and Animation Studies
    • /
    • s.23
    • /
    • pp.1-17
    • /
    • 2011
  • The paper analyzed the metaphoric expressions appeared in whose cinematic quality has been subjectively recognized on the global stage by winning the Oscar for Best Animated Short Film. Many contents and visual effects of the film were expressed with metaphor. Story and sequence were analyzed through the language system-based 'Conceptual Metaphor Analysis Framework'. In addition, characters have been analyzed through the 'Visual Metaphor Analysis Framework'. The framework is to analyze visual dimensions which are derived when concepts are structuredin animation. This paper has attempted to investigate and reveal patterns how animation self-organizes or how animation self-realizes through linguistic objectives. That is, it is to reveal how animation communicates with the audience from the metaphoric perspective among many conventional ones. In an animated film, metaphor is a fundamental means to connect fragmented images, produce a holistic view and therefore induce creative communication with the audience. The essential motive of metaphor which is expressed in various styles in is modern people's feeling of loss and sense of missing something. Train, bottle top, food, lost-and-found center, in-between space and lost items have significance across the movie. According to an analysis, metaphor offers simplicity and freshness as an aesthetic function. In addition, the metaphor expresses lengthy contents and various meanings implicitly, delivering an economic function. With a creative function, metaphor is a tool to generate new meanings. In other words, an animated film is a medium to inspire and move the general public as a means of communication and thinking, not just an entertainment for young generations. After all, metaphoric expressions have been used to deliver diverse and deep meanings in animated films.