• Title/Summary/Keyword: Sequence generator

Search Result 180, Processing Time 0.036 seconds

On a High-Speed Parallel-LM Binary Sequcence Generator (고속 병렬형 LM 이진 수열 발생기)

  • Lee, Hoon-Jae
    • The KIPS Transactions:PartC
    • /
    • v.10C no.7
    • /
    • pp.851-856
    • /
    • 2003
  • The LM generator is an improved summation generator with maximum period, near maximum linear complexity and maximum order of correlation immunity, and it has a property with the input-output correlation immunity In this paper, we propose the high-speed m-parallel LM-BSG and 8-parallel LM-BSG for detail as a design example. When compared with a conventional stream cipher, the properties of the proposed cipher exhibited the same crypto-degree (security) with a rt times faster processing.

A Study on the Implementation of CAM Generator Using Objected-Oriented Programming (객체 지향형 프로그래밍을 이용한 CAM 생성기 구현에 관한 연구)

  • 백인천;박노경;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.12
    • /
    • pp.1313-1323
    • /
    • 1991
  • n this thesis CAM(content Addressable Memory) generator and graphic display tool for run-plot sequence in automatic generation of CAM are presented. We show that implementing the layout generation, graphic menu, mouse driver, and data structure by using the basic classes is clear and easy in modification than the conventional procedural language. For the implementation of generator which is independent of design rule or process, we use the parameterized cell so that basic cell can be changed according to user's inputs. and perform the layout by means of placement and routing using pitch mathching. Finally, the display of CIF which generated and constitution of graphic menu for total run-plot sequence are explained.

  • PDF

Robust Digital Watermarking Using Chaotic Sequence (카오스 시퀀스를 이용한 견고한 디지털 워터마킹)

  • 김현환;정기룡
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.630-637
    • /
    • 2003
  • This paper proposed a new watermarking algorithm using chaotic sequence instead of conventional M-sequence for protecting copyright to the author. Robustness and security is very important for watermarking process. We use multi-threshold value according to the human visual system for improving robustness of watermarking to each subband images coefficient differently after wavelet transform. And then, we embedded watermark image to original image by multi-watermark weights which are made by random sequence generator. We detect watermark image from the difference data which is made from each wavelet subband images. We also simulate the efficiency from the various possible attacks. Chaotic sequence is better than M-sequence, because the one is very easy to make sequence and the chaotic sequence is changed easy according to the initial value. So, the chaotic sequence has the better security than the conventional M-sequence.

A Study on the Cryptographic Properties of FCSR Sequences (FCSR 난수열의 암호학적인 특성에 관한 연구)

  • 서창호;김정녀;조현숙;김석우
    • The KIPS Transactions:PartC
    • /
    • v.8C no.1
    • /
    • pp.12-15
    • /
    • 2001
  • A summation generator creates sequence from addition with carry of LFSR (Linear Feedback Shift Register) sequences. Similarly, it is possible to generate keystream by bitwise exclusive-oring on two FCSR sequences. In this paper, we described the cryptographic properties of a sequence generated by the FCSRs.

  • PDF

ON A SECURE BINARY SEQUENCE GENERATED BY A QUADRATIC POLYNOMIAL ON $\mathbb{Z}_{2^n}$

  • Rhee, Min-Surp
    • Journal of applied mathematics & informatics
    • /
    • v.29 no.1_2
    • /
    • pp.247-255
    • /
    • 2011
  • Invertible functions with a single cycle property have many cryptographic applications. The main context in which we study them in this paper is pseudo random generation and stream ciphers. In some cryptographic applications we need a generator which generates binary sequences of period long enough. A common way to increase the size of the state and extend the period of a generator is to run in parallel and combine the outputs of several generators with different period. In this paper we will characterize a secure quadratic polynomial on $\mathbb{Z}_{2^n}$, which generates a binary sequence of period long enough and without consecutive elements.

A study of M-sequence Signal Generator for Determining System Dynamics (제어 계통의 동특성 측정을 위한 M계열 신호발생기)

  • 박상희;박장춘
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.2
    • /
    • pp.26-32
    • /
    • 1970
  • Among the various methods used for determining control system dynamics, the method using cross-correlation function seems useful if the white noise can be available as a test signal. In this paper, results are reported of a M-sequence generator which was built by means of IC shift register as it designed by the authors. This signal appears very useful and promises future applications in adaptive control systems.

  • PDF

Analysis of Transient Characteristics for Turbopump-fed Liquid Propellant Rocekt Engine in Start-up (터보펌프식 액체 로켓 엔진의 시동 과도 특성 해석)

  • Son, Min;Kim, Duk-Hyun;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.34-37
    • /
    • 2010
  • One dimensional transient analysis was studied for turbopump-fed liquid propellant rocket engine(LRE) system in starting using AMESim. The effects of timing of gas generator fuel valve opening and gas generator ignition to start-up stability were researched for open cycle type system using LOX/RP-1 to propellants. Result show that the parameters and sequence on start-up should be considered to design optimized turbopump-fed LRE system.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

The Design of ASIC chip for Memory Tester (Memory Tester용 ASIC 칩의 설계)

  • Joung, J.W.;Kang, C.H.;Choi, C.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.153-155
    • /
    • 2004
  • In this paper, we design the memory tester chip playing an important role in the memory tester as central parts. Memory tester has the sixteen inner instructions to control the test sequence and the address and data signals to DUT. These instructions are saved in memory with each block such as sequencer and pattern generator. Sequencer controls the test sequence according to instructions saved in the memory. And Pattern generator generates the address and data signals according to instructions saved in the memory, too. We can use these chips for various functional test of memory.

  • PDF

The study for function and operation of the excitation equipment for short circuit generator (단락발전기 용 여자장치의 조작과 기능에 대한 고찰)

  • Kim, Sun-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.735-736
    • /
    • 2008
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, CLR, Back Up Breaker, Making Switch and Excitation Equipment etc. Gradually an allowable tolerance of the short circuit test voltage is become smaller by the standards for short circuit test. The excitation equipment of short circuit generator is very important for test voltage is adjusted by the excitation equipment. Especially the excitation equipment must be possessed character of exactitude, durability and inalterability because some times around 10,000 times opening and closing short circuit test is requested by clint, which must be done within one minute. The purpose of this study for function and operation of the excitation equipment which rated DC voltage is 1,000V, rated DC current is 300A, rated out put is 30kW and type is YNEX 97S-441/609, is to help operation of short circuit generator.

  • PDF