• 제목/요약/키워드: Separation technology

검색결과 3,002건 처리시간 0.027초

에어로졸 증착법(Aerosol Depostion method)에 의한 $Ba(Zr_{0.85}Y_{0.15})O_{3-\delta}$-NI 수소분리막 제조 ($Ba(Zr_{0.85}Y_{0.15})O_{3-\delta}$-NI Composite Membrane for Hydrogen Separation by Aerosol Deposition Method)

  • 박영수;최진섭;변명섭;김진호;황광택
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.271-277
    • /
    • 2010
  • $(Ba(Zr_{0.85}Y_{0.15})O_{3-\delta})$ oxide, showing high protonic conductivity at high temperatures and good chemical stability with $CO_2$ are referred to as hydrogen separation membrane. For high efficiency of hydrogen separation ($H_2$ flux and selectivity) and low fabrication cost, ultimate thin and dense BZY-Ni layer has to be coated on a porous substrate such as $ZrO_2$. Aerosol depostion (AD) process is a novel technique to grow ceramic film with high density and nano-crystal structure at room-temperature, and may be applicable to the fabrication process of AD integration ceramic layer effectively. XRD, SEM, X-ray mapping measurements were conducted in order to analyze the characteristics of BZY-Ni membrane fabricated by AD process. it is observed that it is homogeneous distribution for BZY-Ni. The result of $H_2$ permeation rate suggests that BZY-Ni composite is higher than BZY.

Simultaneous Spectrometric Determination of Caffeic Acid, Gallic Acid, and Quercetin in Some Aromatic Herbs, Using Chemometric Tools

  • Kachbi, Abdelmalek;Abdelfettah-Kara, Dalila;Benamor, Mohamed;Senhadji-Kebiche, Ounissa
    • 대한화학회지
    • /
    • 제65권4호
    • /
    • pp.254-259
    • /
    • 2021
  • The purpose of this work is the development of a method for an effective, less expensive, rapid, and simultaneous determination of three phenolic compounds (caffeic acid, gallic acid, and quercetin) widely present in food resources and known for their antioxidant powers. The method relies on partial least squares (PLS) calibration of UV-visible spectroscopic data. This model was applied to simultaneously determine, the concentrations of caffeic acid (CA), gallic acid (GA), and quercetin (Q) in six herb infusion extracts: basil, chive, laurel, mint, parsley, and thyme. A wavelength range (250-400) nm, and an experimental calibration matrix with 21 samples of ternary mixtures composed of CA (6.0-21.0 mg/L), GA (10.0-35.2 mg/L), and Q (6.4-17.5 mg/L) were chosen. Spectroscopic data were mean-centered before calibration. Two latent variables were determined using the contiguous block cross-validation procedure after calculating the root mean square error cross-validation RMSECV. Other statistic parameters: RMSEP, R2, and Recovery (%) were used to determine the predictive ability of the model. The results obtained demonstrated that UV-visible spectrometry and PLS regression were successfully applied to simultaneously quantify the three phenolic compounds in synthetic ternary mixtures. Moreover, the concentrations of CA, GA and Q in herb infusion extracts were easily predicted and found to be 3.918-18.055, 9.014-23.825, and 9.040-13.350 mg/g of dry sample, respectively.

수소분리를 위한 Polyetherimide계 고분자 중공사막의 제조 및 기체투과 특성 (Preparation and Gas Permeation Characteristics of Polyetherimide Hollow Fiber Membrane for the Application of Hydrogen Separation)

  • 권현웅;임광섭;김지현;김성헌;김도형;남상용
    • 멤브레인
    • /
    • 제31권6호
    • /
    • pp.456-470
    • /
    • 2021
  • 본 연구에서는 비용매 유도 상분리법을 이용하여 폴리에테르이미드 계열의 중공사형 분리막을 제조하였다. 제조된 중공사막의 모폴로지 조절을 위해 첨가제로는 THF, Ethanol, LiNO3를 사용하였다. 또한 높은 수소분리막의 개발을 위해 모폴로지와 기체투과성능을 특성평가를 통해 방사조건을 최적화하였다. 그 결과 THF의 함량이 증가할수록 수소/이산화탄소 선택도가 증가하였다. 하지만 trade-off 관계로 인하여 투과율은 감소하였다. Ethanol을 첨가하였을 때는 finger-like 구조를 나타냈고, LINO3를 첨가하였을 때 Sponge 구조를 보였다. 특히, PDMS 코팅층을 최적화한 중공사막의 경우, 투과율은 40 GPU, 수소/이산화탄소 선택도는 5.6을 나타냈다.

Diagnostic metallurgy of porphyry copper-gold deposits in the Pan-Pacific

  • Kim Joe Y.;Kim Sun S.;Shin Hyung J.;Kong Bong S.;Lee Keon K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.581-589
    • /
    • 2003
  • The variable flotation response ores from different deposits results basically from mineralogical association and their differences. Development of new techniques for analyzing the metallurgical performance of flotation and other concentration processes is demanded even in the treatment of rather simple ores such as porphyry ores. Diagnostic metallurgical analysis can be used to quantify the most possible recovery processes. Several porphyry copper/gold ores around the world were used to examine the responses in flotation, gravity separation and cyanidation in order to define the linkage between the recovery processes for both copper and old values. Laboratory batch flotation, gravity separation and cyanidation tests were carried out on these samples. All results were used to correlate the relative recovery of copper and gold, and to predict the highest possible metal recovery in the system. The metallurgical predictions were made according to the flotation conditions used and gravity separation. The results of various concentration processes on each porphyry ore samples are presented and discussed. All seven samples have shown significantly different gold/copper metallurgy. The grade/recovery relationships of gold and copper in the laboratory batch tests for the best results and the plants are given in the Figures below. The results of laboratory tests show that the copper recoveries converged to about $90\%$, but the gold recoveries were spread over $55-80\%$, except the K S ore. Series of standard cyanidation tests on the flotation concentrate samples and gravity separation using Knelson Separator on heads ores were carried out to cross-link the metallurgy and mineralogy of gold in the porphyry ores.

  • PDF

미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계 (Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics)

  • 이병권;칼리크 아민;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.55-61
    • /
    • 2022
  • 다중 암의 동시 진단 기술에 대한 관심이 전 세계적으로 증가하는 추세이며, 진단 난이도를 낮추기 위해 혈액과 같은 미량의 바이오 유체를 이용하여 질병을 진단하는 미세 유체 소자 기반의 액체 생검 기술이 연구되고 있다. 바이오 유체를 이용하여 형광 영상 등을 통해 분석물질의 농도를 측정하는 광학적 바이오 센싱에 있어 민감도를 향상시키기 위한 기술개발이 필요하다. 본 논문에서는 모세관력에 의한 자가구동 기반의 마이크로 채널의 기하학적 구조와 미세 유체 현상만으로 수동적 자기 혈장 분리 기술과 유체 혼합을 통한 분자 인식 활성화 기능을 구현하는 형광 다중 암 진단 센서 플랫폼 구조를 제안하고 설계하였다. 설계된 센서의 혈장 분리부의 성능에 영향을 미치는 파라미터를 확인하기 위해 채널의 수력학적 직경과 종횡비, 유체의 점도를 변수로 설정하여 딘 와류 형성 여부를 시뮬레이션을 통해 확인하였고 최적의 센서 플랫폼 구조를 제시하였다.

$CO_2$ 흡수용 $100Nm^3$/hr급 Vortex Tube의 에너지분리 특성에 관한 실험적 연구 (An Experimental Study on the Energy Separation of the $100Nm^3$/hr Vortex Tube for $CO_2$ Absorption)

  • 김창수;한근희;박성영
    • 청정기술
    • /
    • 제16권3호
    • /
    • pp.213-219
    • /
    • 2010
  • 볼텍스튜브는 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용할 수 있는 장치이다. 이러한 볼텍스튜브의 에너지분리 특성과 물질분리 특성을 활용하여, 연소가스로부터 $CO_2$를 흡수하는 장치의 핵심부품으로 적용할 수 있다. 본 연구에서는 $CO_2$ 흡수용 볼텍스튜브의 기본설계 자료를 구축하기 위하여 에너지분리 성능실험을 수행하였다. 설계를 위한 기초 자료를 확보하기 위하여, 볼텍스 발생기의 오리피스 직경, 노즐면적비 및 튜브의 길이가 에너지분리 특성에 미치는 영향력을 실험을 통하여 분석하였다. 결과적으로 오리피스 직경이 볼텍스튜브의 성능에 지배적인 설계인자임을 확인하였으며, 노즐면적비와 튜브길이의 영향력은 미미하였다. 오리피스 직경이 작고(Dc=0.6D), 노즐면적비가 중간 이상(AR=0.14~0.16)이며, 튜브 길이가 긴 모델(L=16D)이 저온 출구 측과 고온 출구 측의 열전달에서 가장 우수한 성능을 나타내었다. 본 연구의 결과는 $CO_2$흡수용 $100Nm^3$/hr급 볼텍스튜브의 기본설계 자료로 활용될 예정이다. 볼텍스튜브를 적용한 $CO_2$흡수 공정을 적용하면 기존의 대형 흡수탑 대비 상당한 공간과 에너지의 절감 효과가 기대된다.

이산화탄소/수소 분리용 중공사형 기체분리막의 제조 및 특성 (Preparation and Properties of Hollow Fiber Membrane for CO2/H2 Separation)

  • 고형철;전미진;정상철;전용우
    • 멤브레인
    • /
    • 제33권4호
    • /
    • pp.222-232
    • /
    • 2023
  • 본 연구에서는 중공사형 지지체막을 폴리술폰(polysulfone, PSf) 고분자를 이용하여 비용매 상분리법(non solvent induced phase separation, NIPS)에 의해 제조하였다. 제조된 중공사 지지체막을 PDMS와 Pebax를 코팅하여 중공사형 복합막을 제조하고 CO2, H2, O2 그리고 N2에 대한 순수 투과도(permeance)와 선택도를 측정하였다. 제조된 복합막 모듈 중에서 선택도(CO2/H2)가 가장 높은 모듈을 선정하여 모사가스를 사용하여 스테이지컷(stage cut, SC)의 변화에 따라 분리성능을 측정하였다. 이때 사용된 모사가스는 PSA에서 버려지는 off gas의 농도인 CO2 70% : H2 30%인 것을 사용하였다. 1단 실험에서는 H2 농도 약 60%, H2 회수율 12%의 값을 얻을 수 있었다. 낮은 H2 농도와 회수율을 극복하기 위해 2단 직렬 테스트를 수행하였으며, 이를 통해 H2 농도 약 70%, H2 회수율 70%를 달성할 수 있었으며, 이를 통해 CO2/H2 분리에 대하여 분리 공정 구성을 도출할 수 있었다.