• Title/Summary/Keyword: Separating and Cooling System

Search Result 8, Processing Time 0.023 seconds

A Experimental Study on Waste Water Concentration by Separating Method of Freezing (동결분리방법을 이용한 폐수농축에 관한 실험적 연구)

  • Kim, Jung-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.51-52
    • /
    • 2006
  • This study was progressed on the freezing behavior of waste water in relation to freeze concentration method useful to waste water treatment system of small and middle size and which can re-use purified water. The object of this experiment is comparing a pollutant contain of the frozen layer and of an aqueous solution by cooling wall temperature, a flow field effect and a initial thickness of frozen layer.

  • PDF

A Study on the Solid-Liquid Separation of Cooling Water in Ships (선박용 냉각수의 고.액분리에 관한 연구)

  • Choi, M.S.;Kim, J.H.;Jo, D.H.;Han, W.H.;Kim, B.G.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF

Development of Coolant/Waste-oil Separating and Cooling System with Chip Treatment (칩 처리가 포함된 절삭유/폐유 분리 및 냉각 시스템 개발)

  • Kim, Joong-Seon;Lee, Dong-Seop;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.16-23
    • /
    • 2017
  • For most machine tools, it is necessary to remove chips and coolant oil because it they will continue to be created during the manufacture of workpieces. Existing products that are in use are installed and used as they reflect depending on the characteristics of each device separately. This study proposes a method to remove the security chip as well as developing an integrated system capable of reducing coolant damage. The Leverage AutoCAD and CATIA program was used for 2D and 3D design, shapes were identified by utilizing the KeyShot program, and the load and displacement analysis of the development apparatus was performed utilizing the ANSYS program. After the prototype underwent sufficient design review, the mixed oil separation device had a complete sensor control program using the LabVIEW program. The chip design process for transferring experiments and experiments on the mixed oil cooling device were developed for performance tests of the product. The final product resulted in an increase in space utilization during commercialization, reduced installation costs, and caused social effects such as pulmonary flow reduction, which, through the economic costs, reduces pollution, resulting in various benefits to the industry, such as deceased errors in the workplace decreases.

Development of a Method for Separating the Faceplate of used CRT (환경친화적 폐 CRT 분리 시스템 개발)

  • 이화조;임병훈;허성필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.848-851
    • /
    • 2003
  • In this paper, a separating system for used CRT recycling is presented. Depend on manufacturer CRTs has small differences in dimension for the same model, but the dimensions of the panel are nearly same. To simplifying configuration of the system, we developed CRT fixing pallets for every model of CRT. The height of cutting position for every model of CRT will be same. The cutting machine has two rotating arm and use metal-bond type diamond cutting wheel. Instead of water, two vortex tube type air-coolers are used for the cooling of cutter. Workers in recycling factory are generally old people. Therefore, control program should be easy to use and operate. Thus we developed GUI with very simple interface.

  • PDF

Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems (해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성)

  • Kim Bu-Gi;Han Won-Hui;Cho Dae-Hwan;Choi Min-Seon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.2 s.23
    • /
    • pp.109-115
    • /
    • 2005
  • Hydrocyclone has been widely used for the solid-liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range particle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in the efficiency of cooling system In this paper, we have suggested some methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the separating performance of the Hydrocyclone were investigated The results from this study are summarized as follows: 1) In proportion to the decrease of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in machines, and eventually prevent unexpected accidents in engine systems.

  • PDF

Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems (해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성)

  • Kim Bu-Gi;Han Won-Hui;Cho Dae-Hwan;Choi Min-Sun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2004.11a
    • /
    • pp.109-115
    • /
    • 2004
  • Hydrocyclone has been widely used for the solid-liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range particle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested some methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the separating performance of the Hydrocyclone were investigated The results from this study are summarized as follows: 1) In proportion to the decrease of solid concentration, the efficiency of solid-liquid separation is improved 2) According as the cyclone inlet pressure increases the efficiency of separation is improved Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in machines, and eventually prevent unexpected accidents in engine systems.

  • PDF

A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice - (공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향-)

  • 이병화;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

Studies on the Performance Variation of a Variable Speed Vapor Compression System under Fault and Its Detection and Diagnosis (가변속 증기압축 냉동시스템에서 고장시의 성능변화와 고장 감지 및 진단에 관한 연구)

  • Kim Minsung;Kim Min Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • An experimental study has been peformed to develop a scheme for fault detection and diagnosis(FDD) in a vapor compression refrigeration system. This study is to analyze fault effect on the system performance and to find efficient diagnosis rules for easy determination of abnormal system operation. The refrigeration system was operated with a variable speed compressor to modulate cooling capacity. The FDD system was designed to consider transient load conditions. Four major faults were considered, and each fault was detected over wide operating load range by separating the system response to the load change. Rule-based method was used to diagnose and classify the system faults. From the experimental results, COP degradation due to the faults in a variable speed system is severer than that in a constant speed system. The method developed in this study can be used in the fault detection of refrigeration systems with a variable speed compressor.