• Title/Summary/Keyword: Separated construction

Search Result 246, Processing Time 0.028 seconds

Engine room cooling system using jet pump (제트 펌프를 이용한 엔진 룸 냉각 시스템)

  • Lim, Jeong-Woo;Lee, Sang-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.162-167
    • /
    • 2000
  • Construction machinery includes an engine enclosure separated from a cooling system enclosure by a wall to reduce noise and advance cooling system performance. For this structure, however, the axial fan cannot be of benefit to the engine room, and so the temperature rise in the engine room makes several bad conditions. This paper proposes that hot air in engine room is evacuated tv secondary pipe using jet pump. This paper demonstrates the structure and the effect of jet pump and useful guideline on design of area, length, and shape of secondary pipe to maximize the effect of jet pump.

  • PDF

Development of an Autonomous Mobile Robot with Functions of Speech Recognition and Collision Avoidance

  • Park, Min-Gyu;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.475-475
    • /
    • 2000
  • This paper describes the construction of an autonomous mobile robot with functions of collision avoidance and speech recognition that is used for teaching path of the robot. The human voice as a teaching method provides more convenient user-interface to mobile robot. For safe navigation, the autonomous mobile robot needs abilities to recognize surrounding environment and avoid collision. We use u1trasonic sensors to obtain the distance from the mobile robot to the various obstacles. By navigation algorithm, the robot forecasts the possibility of collision with obstacles and modifies a path if it detects dangerous obstacles. For these functions, the robot system is composed of four separated control modules, which are a speech recognition module, a servo motor control module, an ultrasonic sensor module, and a main control module. These modules are integrated by CAN(controller area network) in order to provide real-time communication.

  • PDF

A Method for Text Information Separation from Floorplan Using SIFT Descriptor

  • Shin, Yong-Hee;Kim, Jung Ok;Yu, Kiyun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.4
    • /
    • pp.693-702
    • /
    • 2018
  • With the development of data analysis methods and data processing capabilities, semantic analysis of floorplans has been actively studied. Therefore, studies for extracting text information from drawings have been conducted for semantic analysis. However, existing research that separates rasterized text from floorplan has the problem of loss of text information, because when graphic and text components overlap, text information cannot be extracted. To solve this problem, this study defines the morphological characteristics of the text in the floorplan, and classifies the class of the corresponding region by applying the class of the SIFT key points through the SVM models. The algorithm developed in this study separated text components with a recall of 94.3% in five sample drawings.

CONSIDERATION OF APPLICATION FOR OPTICAL COMPOSITE POWER CABLE (전력/광 복합 케이블의 적용에 대한 고찰)

  • Kim, J.W.;Kim, H.K.;Ha, B.D.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1547-1549
    • /
    • 1994
  • In recent years, fiberoptic technology is becoming indispensable in establishing communication networks due to its low loss, high capacity and non-inductive properties. In the power industry as well, the technology is being required to cable and facility monitering, and control system. But, duct in the manhole and space in the culvert are required to fiberoptic cable that is separated from power cable. Therefore, some cable makers and R&D has been studying the composite fiber/power cables. This report introduces the outline of ABF system, construction and properties of optical composite power cable that used ABF technology.

  • PDF

A Study on The Design of Network and Database Structure of The Integrated System for Power System Operational Planning and Analysis (전력수급계획 및 운용해석 종합시스템을 위한 네트워크 및 데이터베이스구조 설계에 관한 연구)

  • Ahn, Yang-Keun;Park, Si-Woo;Nam, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1009-1011
    • /
    • 1998
  • This paper presents a design of network and database structure of the integrated system for power system operational planning and analysis that will be more economical and stable of power system operation. An alias of this system is Highly Integrated Total Energy System(HITES). The Client/server model of HITES is designed as a remote data management model. The input/output-type of application programs and Oracle server is standardized. The separated user-databases from main-database strengthen security of HITES. It is plan to do that tables and relationships are defined by database designs. The connection of application program and DBMS of HITES will be tested through database design and data construction.

  • PDF

Estimation of modal correlation coefficients from background and resonant responses

  • Denoel, V.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.6
    • /
    • pp.725-740
    • /
    • 2009
  • A new simple relation for the estimation of modal correlation coefficients is presented. It is obtained from the decomposition of covariances of modal responses into background and resonant contributions, as it is commonly done for the variances. Thanks to appropriate assumptions, the modal correlation coefficients are estimated as weighted sums of two limit values, corresponding to the background and resonant responses respectively. The weighting coefficients are expressed as functions of the background-to-resonant ratios, which makes the proposed formulation convenient and easily accessible. The simplicity of the mathematical formulation facilitates the physical interpretation. It is for example proved that modal correlation coefficients can be non negligable even in case of well separated natural frequencies, which is sometimes unclear in the litterature. The new relation is mainly efficient in case of large finite element models. It is applied and validated on a finite element buffeting analysis of the Viaduct of Millau, the highest bridge deck ever built so far.

A Comparative Case Study on Entrusting of Infrastructure Maintenance (시설유지보수 위탁방안 해외사례연구)

  • 방연근;문대섭;정병현
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.67-85
    • /
    • 2002
  • This study analysed how to divide the maintenance of infrastructure in overseas countries' rail reform from train operation to get implications for KNR's reform. Sweden and United Kingdom divided the maintenance of infrastructure from train operation. France divided the two functions just only in laws and train operator is entrusted the maintenance of infrastructure. Germany divided the two functions but not completely, so integrated indirectly through the holding company, DB AG. Japan integrated the two functions into train operator, but separated the construction of infrastructure from the train operator. From these analysis, the authors suggest to make clear the goals of rail reform to assess the success or failure of dividing the two functions directly or indirectly.

  • PDF

Necessity to Install Integrated Control Tower for Overseas Energy Resources Acquisition and Securing Funds (해외에너지자원획득과 소요자금 확보를 위한 통합 컨트롤 타워 설치 필요성에 관한 연구)

  • Kang, Ji-Kwang;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.6 no.3
    • /
    • pp.40-45
    • /
    • 2010
  • Necessity to install control towers has been studied to acquire overseas energy resources and to secure funds. At present, domestic energy companies do business independently. Institutions which support plant EPC companies as partners of package deal are separated. This causes the low records at package deal for overseas resources acquisition. Except UK and USA, nations which have major companies developed overseas energy resources early by promoting a large national company. Consequently, they currently have good records. This study suggests the necessities to install integrated control tower for overseas energy resources acquisition and securing funds and the following are the ways ; 1) promote a large national company by consolidation of separate energy companies, 2) install plant EPC promotion department which support private plant EPC companies, 3) make a integrated control tower in high level government office to connect between a large national company and plant EPC promotion department.

  • PDF

Synchronous Visible Light Communication Systems Using 3-Level LED Modulation (3-Level LED 변조를 이용한 동기식 가시광통신 시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.421-427
    • /
    • 2013
  • In this paper, we introduce a new synchronous visible light communication system in which the synchronizing pulse and the data bits are simultaneously transmitted using a 3-level light signal. In the transmitter, the synchronizing pulse and the data bits modulate independently two identical visible LEDs, whose output lights add in free space, make 3-level optical signal. In the receiver, a photodiode detects the light and generates a 3-level output voltage, whose positive and negative part correspond to the synchronizing pulse and the data bits, respectively. The two signals are easily separated and recovered by a simple diode circuit. This configuration provides two independent VLC channels without any multiplexing technique, simplifies the circuit design and construction of synchronous VLC systems.

An Analysis on the Characteristic of the Dressing-Room Planning in the Apartment Building (공동주택의 드레스룸 공간계획 특성에 관한 연구)

  • Park, So-Yun;Lee, Kyung-A;Lee, Hyun-Soo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.44-47
    • /
    • 2005
  • The purpose of this study is to identify the characteristics of the Dressing-Room lay-out in brand-apartments as the strategy for the differentiation. The 441 floor-plans are collected by searching web-sites of the 5 main construction companies. The major findings are summarized as follows: (1) The Dressing-Rooms are designed in the 331 cases among 441 the floor-plans including the Dressing-Room are generally over 30 Pyeong(about 99 square meters). In addition, the entire cases above 60 Pyeong(about 198 square meters) include the Dressing-Room. (2) The size of the Dressing-Room is increased in proportion to the square meter. However, the ratio is the small range of fluctuation. (3) The types of Dressing-Room units are classified 4 categories : a dressing-room joined powder room, a dressing-room separated from bathroom, a dressing room without powder room, a powder room centering with dressing room and bathroom.

  • PDF