• Title/Summary/Keyword: Seoul Metropolitan

Search Result 3,482, Processing Time 0.048 seconds

A Survey on the population of Toxigenic Fungi in Crude Drugs in Seoul (시판 유통중인 한약재에서의 위해성 진균 분포에 관한 연구)

  • Lee Young-Ki;Park Ok-Soon;Oh Young-Hee;Kim Mu-Sang;Kim Young-Soo
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.2 s.56
    • /
    • pp.29-32
    • /
    • 2005
  • We just carried out this study in order to obtain an appropriate information of the population of toxigenic fungi in crude drugs in seoul. Results of fungal examination on twenty-three kinds crude drugs were described in this report. In 21 crude drugs, colonies of fungi were possible to identify into 7 genera. Predominant genera of fungi in crude drugs were Aspergillus spp. $(14,\;46.6\%)$, Scopulariospsis spp. $(7,\;23.3\%)$, Penicillium spp., Rhizopus spp., Fusarium spp $(2,\;6.6\%,\;respectively)$ and Phoma sp., Chaetomium sp. $(1,\; 3.3\%,\;respectively)$. Mycotoxin producing fungi like Aspergillus spp., Penicillum spp., and Fusarium spp. were 18 colonies$(60\%)$, totally.

The Characteristic and Management of Odor Emitted from Foodwaste Treatment Facility (음식물류폐기물 처리시설에서의 악취발생 특성 및 관리방안)

  • Yoo, Seung-Sung;Kim, Young-Doo;Lee, Jun-Yeon;Cha, Young-Seop;Kim, Eun-Sook;Jeon, Jae-Sik;Sunwoo, Young;Eom, Seok-Won;Chae, Young-Zoo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.353-365
    • /
    • 2012
  • This study is understanding characteristics and analyzing contributions of the odor causing compounds of complex-odor & major specified odor materials, and contribution analysis, caused pre-treatment facilities(input and storage) and post-treatment facilities(heating and drying). The target of this study is feeds-production-facilities, located in Seoul. The averaged complex-odor compounds on the boundary line is 21 times higher, and it is 15 times higher than emission standards. In cracking&collection(pre-treatment facilities), the concentration of compounds is 4,881 times, 2,080 times in drying, and 1,442 times in putting&storing facilities. Ammonia occupies the largest portion of the results of monitoring specified odor compounds in input&storage facilities, followed Acetaldehyde > Hydrogen sulfide > Methyl mercaptan. In cracking&collection, Ammonia also occupies most of odor compounds, followed Methyl mercaptan > Acetaldehyde > Dimethyl disulfide > Dimethyl sulfide > Hydrogen sulfide. Acetaldehyde > Methyl mercaptan in drying facilities. On the boundary line, however, the concentration of specified odor compounds stays below emission standards. The result of contribution analysis is that methyl mercaptan has the highest contribution in input & storage, as well as cracking&collection facilities, followed Acetaldehyde > Hydrogen sulfide > Dimethyl sulfide > Dimethyl disulfide. In the drying facilities, the contribution shows Methyl mercaptan > Acetaldehyde > i-Valeraldehyde and Butyraldehyde. Therefore, to decrease odor in foodwaste treatment facilities, proper prevention facilities need to be installed and operated, according to characteristics of individual odor compounds, based on monitored data.

The Content and Risk Assessment of Heavy Metals in Herbal Medicines used for Food and Drug (식약공용 농·임산물의 유해중금속 분석 및 위해도 평가)

  • Cho, In-Soon;Kim, Su-Jin;Park, Ae-Suk;Kim, Jin-Ah;Jang, Jung-Im;Lee, Sung-Deuk;Yu, In-Sil;Shin, Yong-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.354-364
    • /
    • 2020
  • For this paper we analyzed heavy metals including lead, cadmium, arsenic and mercury, and conducted risk assessment on 171 types of herbal medicines used as foods and drugs distributed in Seoul's Yangnyeongsi and Kyungdong (Gyeongdong) herbal medicine markets. The concentrations of the heavy metals were measured by the ICP-MS and a mercury analyzer. The detection ranges of the lead, cadmium, arsenic and mercury were found to be ND-4.719 mg/kg, ND-1.019 mg/kg, 0.002-8.696 mg/kg and ND-0.058 mg/kg, respectively. Artemisiae Capillaris Herba exceeded the standards of the MFDS (Ministry of Food and Drug Safety) for cadmium items, and Actinidiae Ramulus et Fulium et Fructus Vermicultus exceeded the standards for arsenic items. The non-carcinogenic risk assessment showed that there were no items exceeding 1 and that they were safe. The risk of carcinogenicity to lead was below 10-6 in all items and was evaluated as safe. The risk of carcinogenicity of arsenic was almost all in the range of 10-4 to 10-6. All %PTWI are considered to be safe below 100.

Residue analysis and risk assessment of ethoxyquin and ethoxyquin dimer in farmed fish (양식어류 중 Ethoxyquin과 Ethoxyquin dimer의 잔류분석 및 위해평가)

  • Choi, Young-Hee;Ko, Suk-Kyung;Ryu, Seung-Hee;Jin, Young-Hee;Kwak, Jae-Eun;Lee, Myung-Sook;Kim, Bog-Soon;Hang, In-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.3
    • /
    • pp.239-244
    • /
    • 2021
  • In the present study, liquid chromatography tandem-mass spectrometry was used to conduct a risk assessment of ethoxyquin and ethoxyquin dimer residues in 288 farmed fish sold in wholesale and traditional markets in Seoul. The detection range (detection rate) of ethoxyquin and ethoxyquin dimer was 0.005~0.309 mg/kg (4.9%) and 0.001~2.828 mg/kg (69.8%), respectively. Ethoxyquin was detected only in freshwater eels, loaches, catfish, and flatfish, whereas ethoxyquin dimer was present in all fish species. To estimate the dietary exposure levels of ethoxyquin and ethoxyquin dimer, the hazard index, calculated using the acceptable daily intake and estimated daily intake, ranged from 0.001 to 0.300%. Our results indicate that there is no significant exposure risk to humans from these farmed fish despite 10 farmed fish samples exceeding the maximum residue level (1.0 mg/kg as the sum of ethoxyquin and ethoxyquin dimer).

A Study on Hazardous Heavy Metal Contents of Lip Cosmetics (립메이크업 제품의 유해 중금속 함량 조사연구)

  • Choi, Chae Man;Kim, Su Un;Park, Ae Suk;Kim, Ji-Young;Kim, Yun Hee;Lee, Myung Sook;Kim, Uk Hee;Hwang, In Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.2
    • /
    • pp.147-155
    • /
    • 2022
  • From March to August 2021, a total of 66 lip makeup products were collected from Seoul to measure the contents of lead, arsenic, cadmium, antimony, and nickel, and compared by product type (lip gloss, lip balm and lip tint), production area (domestic and imported), and user (for adults and children). The average metal contents were as follows; 0.284 ㎍/g for lead, 0.020 ㎍/g for arsenic, 0.003 ㎍/g for cadmium, 0.004 ㎍/g for antimony and 0.415 ㎍/g for nickel. The results of lip cosmetics were below the recommended maximums in regulations on safety standards for cosmetics of Ministry of Food and Drug Safety.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF