• Title/Summary/Keyword: Sensor technology

Search Result 8,666, Processing Time 0.034 seconds

Inter-comparison of temperature measurement capability using standard platinum resistance thermometers (표준백금저항온도계를 이용한 온도측정능력 상호비교)

  • Gam, K.S.;Kang, C.S.;Lee, Y.J.;Lee, K.B.;Kim, Y.G.;Park, S.N.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

The characteristics of Pt thin films prepared by DC magnetron sputter (DC Magnetron Sputter로 제조된 Pt 박막의 특성)

  • Na, Dong-Myong;Kim, Young-Bok;Park, Jin-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.159-164
    • /
    • 2007
  • Thin films of platinum were deposited on a $Al_{2}O_{3}/ONO(SiO_{2}-Si_{3}N_{4}-SiO_{2})/Si$-substrate with an 2-inch Pt(99.99 %) target at room temperature for 20, 30 and 60 min by DC magnetron sputtering, respectively X-ray diffract meter (XRD) was used to analyze the crystallanity of the thin films and field emission scanning electron microscopy (FE-SEM) was employed for the investigation on crystal growth. The densification and the grain growth of the sputtered films have a considerable effect on sputtering time and annealing temperatures. The resistance of the Pt thin films was decreased with increasing deposition time and sintering temperature. Pt micro heater thin film deposited for 60 min by DC magnetron sputtering on an $Al_{2}O_{3}$/ONO-Si substrate and annealed at $600^{\circ}C$ for 1 h in air is found to be a most suitable micro heater with a generation capacity of $350^{\circ}C$ temperature and 645 mW power at 5.0 V input voltage. Adherence of Pt thin film and $Al_{2}O_{3}$ substrate was also found excellent. This characteristic is in good agreement with the uniform densification and good crystallanity of the Pt film. Efforts are on progress to find the parameters further reduce the power consumption and the results will be presented as soon as possible.

Temperature dependence of photocurrent for the AgInS2 epilayers grown by hot wall epitaxy (Hot Wall Epitaxy 방법에 의해 성장된 AgInS2 박막의 광전류 온도 의존성)

  • Park, Chang-Sun;Hong, Kwang-Joon;Lee, Sang-Youl;You, Sang-Ha;Lee, Bong-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • A silver indium sulfide ($AgInS_{2}$) epilayer was grown by the hot wall epitaxy method, which has not been reported in the literature. The grown $AgInS_{2}$ epilayer has found to be a chalcopyrite structure and evaluated to be high quality crystal. From the photocurrent measurement in the temperature range from 30 K to 300 K, the two peaks of A and B were only observed, whereas the three peaks of A, B, and C were seen in the PC spectrum of 10 K. These peaks are ascribed to the band-to-band transition. The valence band splitting of $AgInS_{2}$ was investigated by means of the photocurrent measurement. The crystal field splitting, ${\Delta}cr$, and the spin orbit splitting, ${\Delta}so$, have been obtained to be 0.150 eV and 0.009 eV at 10 K, respectively. And, the energy band gap at room temperature has been determined to be 1.868 eV. Also, the temperature dependence of the energy band gap, $E_{g}$(T), was determined.

Characteristics of conductive rubber belt on the abdomen to monitor respiration (호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성)

  • Kim, Kyung-Ah;Kim, Sung-Sik;Cho, Dong-Wook;Lee, Seung-Jik;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.24-32
    • /
    • 2007
  • Conductive rubber material was molded in a belt shape to measure respiration. Its resistivity was approximately $0.03{\;}{\Omega}m$ and the resistance-displacement relationship showed a negative exponent. The temperature coefficient was approximately $0.006{\;}k{\Omega}/^{\circ}C$ negligible when practically applied on the abdomen. The conductive rubber belt was applied on a normal male's abdomen with the dimensional change measured during resting breathing. The abdominal signal was differentiated ($F_{m}$) and compared with the accurate standard air flow rate signal ($F_{s}$) obtained by pneumotachometry. $F_{m}$ and $F_{s}$ differed in waveform, but the start and end timings of each breaths were clearly synchronized, demonstrating that the respiratory frequency could be accurately estimated before further processing of $F_{m}$. $F_{m}-F_{s}$ loop showed a nonlinear hysteresis within each breath period, thus 6 piecewise linear approximation was performed, leading to a mean relative error of 14 %. This error level was relatively large for clinical application, though customized calibration seemed feasible for monitoring general variation of ventilation. The present technique would be of convenient and practical application as a new wearable respiratory transducer.

Electrochemical Immunosensor Based on the ZnO Nanorods Inside PDMS Channel for H7N9 Influenza Virus Detection (PDMS 채널 내부에 성장된 산화아연 나노막대를 이용한 H7N9 인플루엔자 바이러스 전기화학 면역센서)

  • Han, Ji-Hoon;Lee, Dongyoung;Pak, James Jungho
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.278-283
    • /
    • 2014
  • In this study, we propose an immunosensor using zinc oxide nanorods (NRs) inside PDMS channel for detecting the influenza A virus subtype H7N9. ZnO with high isoelectric point (IEP, ~9.5) makes it suitable for immobilizing proteins with low IEP. In this proposed H7N9 immunosensor structure ZnO NRs were grown on the PDMS channel inner surface to immobilize H7N9 capture antibody. A sandwich enzyme-linked immunosorbent assay (ELISA) method with was used 3,3',5,5' tetramethylbenzidine (TMB) for detecting H7N9 influenza virus. The immunosensor was evaluated by amperometry at various H7N9 influenza antigen concentrations (1 pg/ml - 1 ng/ml). The redox peak voltage and current were measured by amperometry with ZnO NWs and without ZnO NWs inside PDMS channel. The measurement results of the H7N9 immunosensor showed that oxidation peak current of TMB at 0.25 V logarithmically increased from 2.3 to 3.8 uA as the H7N9 influenza antigen concentration changed from 1 pg/ml to 1 ng/ml. And then we demonstrated that ZnO NRs inside PDMS channel can improve the sensitivity of immunosensor to compare non-ZnO NRs inside PDMS channel.

Transfer of Heat-treated ZnO Thin-film Plastic Substrates for Transparent and Flexible Thin-film Transistors (투명 유연 박막 트랜지스터의 구현을 위한 열처리된 산화아연 박막의 전사방법 개발)

  • Kwon, Soon Yeol;Jung, Dong Geon;Choi, Young Chan;Lee, Jae Yong;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.182-185
    • /
    • 2018
  • Zinc oxide (ZnO) thin films have the advantages of growing at a low temperature and obtaining high charge mobility (carrier mobility) [1]. Furthermore, the zinc oxide thin film can be used to control application resistance depending on its oxygen content. ZnO has the desired physical properties, a transparent nature, with a flexible display that makes it ideal for use as a thin-film transistor. Though these transparent flexible thin-film transistors can be manufactured in various manners, manufacturing large-area transistors using a solution process is easier owing to the low cost and flexible substrate. The advantage of being able to process at low temperatures has been attracting attention as a preferred method. However, in the case of a thin-film transistor fabricated through a solution process, it is reported that charge mobility is lower. To improve upon this, a method of improving the crystallinity through heat treatment and increasing electron mobility has been reported. However, as the heat treatment temperature is relatively high at $500^{\circ}C$, an application where a flexible substrate is absent would be more suitable.

Dopamine determination using a biosensor based on multiwall carbon nanotubes paste and burley tobacco-peroxidase (담배 잎-peroxidase와 다중벽 탄소 나노튜브를 이용한 dopamine의 정량)

  • Kwon, Hyoshik;Jeon, Byong-Suk;Pak, Yongnam
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.98-105
    • /
    • 2015
  • The development of an enzymatic biosensor for dopamine determination based on multiwall carbon nanotubes (MWCNTs) and peroxidase obtained from the crude extract of burley tobacco (Nicotiana tabacum L.) was proposed. Peroxidase catalyzes the oxidation of dopamine to dopamine quinone. The influence on the response of analytical parameters of biosensors such as enzyme concentration, dopamine concentration, pH, and phosphate buffer solution concentration were investigated. The analytical parameters obtained, including sensitivity, linearity, and stability, were investigated. The proposed method for dopamine determination presented good selectivity even in the presence of uric acid and ascorbic acid. The sensor presented a higher response for dopamine in 0.010 M phosphate buffer at pH 6.50, with an applied potential of -0.15 V. The detection limit of the electrode was 2.7×10−6 M (S/N = 3) and the relative standard deviation of the measurements, which were repeated 10 times using 5.0×10−2 M dopamine, was 1.3%.

Design of Solar Tracking CanSat (태양위치추적 캔위성의 개발)

  • Jung, In-Jee;Moon, Ji-Hwan;Kim, Min-Soo;Lim, Byoung-Duk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.4
    • /
    • pp.327-334
    • /
    • 2013
  • In August 2012 the first CanSat competition was hosted by the Satellite Research Center of KAIST under auspice of the Ministry of Education, Science and Technology. The present authors team won the first prize in the university session. In this paper the overall procedure of the CanSat project presented from the conceptual design stage to the final launch test. As the compulsory mission CanSat should send GPS data and attitude information to the ground station which in practice was performed via Bluetooth channel. In addition our CanSat is designed to trace the sun for the solar panels supplying electric power of satellite. IMU and servo motors are used for the attitude control in order that the solar sensor of the CanSat is always direct towards the sun. Launching of CanSat was simulated by dropping from a balloon at the height of around 150m via parachute. Launching test results showed that the attitude control of the CanSat and its solar sensing function were successful.

Validity Study of Dynamic Balance Abilities Measure using a Smartphone (스마트폰을 이용한 동적균형능력 측정의 타당도 연구)

  • Han, Seul-Ki;Lee, Sang-Yong;Lee, Dae-Hee;Park, Jung-Seo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.77-82
    • /
    • 2016
  • PURPOSE: The purpose of this study was to investigate the validity of dynamic balance measurements using a smartphone. METHODS: Thirty subjects were selected out of Y-university students without fractures, operation history, and inflammatory arthritis who had not started regular exercise during the past three months. Their dynamic balance ability was measured by the Biodex Balance System (Biodex Medical Systems, Inc., USA) using smartphones. The smartphone utilized in this study was the Galaxy Note4 LTE (SM-N910K, Samsung, Korea), and the application was the Sensor Kinetics pro (Ver.2.1.2, INNOVENTIONS Inc, US). The dynamic balance ability was measured in triplicate. RESULTS: With eyes closed, a low level of correlation (r>0.30, p<0.05) and low reliability (ICC>0.60) were determined between the roll value of the smartphone gyroscope versus the medial/lateral score of the Biodex Balance System. With eyes closed, a low level of correlation (r>0.30, p<0.05) and low reliability (ICC>0.60) were determined between the total value of the smartphone gyroscope versus the total score of the Biodex Balance System. CONCLUSION: This study indicated that using a smartphone can generate highly limited data regarding balance ability. They are unlikely to replace the existing more expensive devices entirely. However, smartphones may be highly useful in environments in which an expensive device is not available or when dynamic balance ability should be measured immediately or within a few hours.

A PRACTITIONERS VIEW OF MODERN DEVELOPMENTS IN LIMNOLOGY

  • IMBERGER J.;ANTENUCCI J.;BRUCE L.;DUCAS A.;EWING T.;FEAVER S.;HIPSEY M.;IMERITO A.;LAM C.;MORILLO S.;ROMERO J.;SHIMIZU K.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.09a
    • /
    • pp.11-12
    • /
    • 2005
  • With the great advances in process understanding, sensor and instrumentation technology and modelling capability it is important to ask what if any practical benefits can the lake manager and operator look forward to. Here, we examine some of the more important problems facing operators of drinking reservoirs, hydro-lakes and lakes used predominantly for recreation and the environment. In drinking reservoirs the main problems originate from increased loadings of nutrients leading to increased biomass and biomass that may give rise to toxins, of anthropogenic chemicals such as metals and synthetic organics and of pathogens of different types. Hydro-lakes are predominantly plagued by problems arising from low oxygen levels in the hypolimnion and in recreational and environmentally sensitive lakes the biggest challenge for the operator is to maintain an existing or establish a new trophic hierarchy or protect the water body from foreign species. The control variables that are at an operator's disposal are the choice of lake water level, the modification of the water colunm stratification via a de-stratification system, the modification of the lake flow path with flow intervention. curtains, intervention in the catchments to modify the loadings flowing into a lake, manipulation of the trophic chain with introduction of new species and chemical dosing, the latter being of marginal use in a large lake. Each of these options is cost effective under certain-circumstances. We endeavour to provide a users guide for their application and show how, especially new instrumentation and modelling methodologies may be used to achieve an effective intervention.

  • PDF