• 제목/요약/키워드: Sensor flow

검색결과 878건 처리시간 0.028초

버클링 마이크로 적층형 압전밸브의 제작 (Fabrication of a buckling micro MCA valve)

  • 이종화;정귀상
    • 센서학회지
    • /
    • 제15권1호
    • /
    • pp.47-52
    • /
    • 2006
  • This paper describes the design, fabrication and characteristics of a buckling microvalve using a MCA (multilayer ceramic actuator). The mechanical and fluidic analysis are done by finite element method. The designed structure is normally closed microvalve using buckling effect, which is consist of three separate structures; a valve seat die, an actuator die and a small piezoelectric actuator. The flow rate of the fabricated MCA valve was 0-8.13 ml/min at the applied pressure of 0-50 kPa. Maximum non-linearity was 2.24 % FS at a duty cycle of 50 %. The maximum pressure was 230 kPa and the leak rate was $3.03{\times}10^{-8}\;Pa{\cdot}m^{3}/cm^{2}$ at a supply voltage of 100 V.

모터링 압력측정을 통한 상사점 결정방법에 관한 연구 (A study on TDC crank angle determination by motoring pressure measurement)

  • 한정옥;이영주;김승수
    • 오토저널
    • /
    • 제10권6호
    • /
    • pp.39-47
    • /
    • 1988
  • A disk photo sensor system was constructed and installed on engine for the crank angle measurement. Statically measured TDC crank angle data were compared with those obtained from engine motoring. Two groups of cylinder pressure data were compared each other, one measured by pressure transducer mounted flush on the combustion chamber and the other obtained with the help of spark plug type adaptor. A simple analysis on the gas flow in the spark plug type pressure transducer displayed reasonably good agreement with those from engine motoring tests. In various firing tests, the IMERs obtained from the spark plug type pressure transducer turned out to be higher than those from the flush mounted one at low engine speed while those two were nearly the same at high engine speed. As the engine load decreased the relative difference in IMEP measurement between the two types tended to be enlarged.

  • PDF

아몰퍼스 자왜 와이어의 센싱기능에 관한 연구 (A Study on the Sensing Function of Amorphous Magnetostrictive Wire)

  • 조남희;신용진;서강수;임재근;문현욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.89-92
    • /
    • 1996
  • In this paper, we mention the study on the sensing function of amorphous magneto- striction wire with about 125${\mu}{\textrm}{m}$$\Phi$ in diameter. The wire in fabricated by using injection and quenching method under the high speed rotating water flow. The wire\`s compotion is (Fe$_{75}$ $Co_{25}$)$_{77}$Si$_{8}$B$_{15}$ , and generates sharp Matteucci voltage by large Barkhausen jump effect even the weak magnetic field. In this study, we don\`t use pick-up coil. Instead, we apply external magnetic field of 3.6Oe in the direction orthogonal to the wire. Then, we detect Matteucci voltage of 1.lmV to both side of 20cm amorphous-wire. Thus, we find that the fabricated wire has the function necessary as the high sensitive sensor material.l.al.l.

  • PDF

고주파 임피던스를 이용한 토양수분함량 측정에 관한 연구 (Measurement of Soil Moisture Content Using RF Impedance in the Range of 1 to 30MHz)

  • 김기복;이남호;노상하
    • 한국농공학회지
    • /
    • 제40권6호
    • /
    • pp.79-88
    • /
    • 1998
  • This study was conducted to measure the moisture content of soil using RF impedance in the range of 1 to 30MHz. Considering the water potential flow in the soils, two types of sensor such as parallel cylinder and perpendicular plate type were fabricated and tested. The capacitance and resistance of sonsors for soil samples having moisture content range of 2 to 27% were measured by Q-meter (HP4342). The higher soil moisture content was and the larger soil bulk density was, the more the capacitance of sensors increased. To eliminate the effect of bulk density on measuring soil moisture content using RF impedance, two kinds of model having the density independent functions such as the ratio of capacitance change to conductance change and weight of water and dry soils respectively were developed and estimated by regression analysis.

  • PDF

다공질 폴리우레탄 폼 매트릭스 축류 회전형 열교환기의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance of Axial Flow Rotary Heat Exchanger with the Porous Polyurethane Foam Matrix)

  • 태춘섭;박상동;조성환;최영돈
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.44-54
    • /
    • 1993
  • This is an experimental study to identify the performance of air-to-air rotary heat exchanger with polyurethane foam matrix. The experimental apparatus including heating AHU(Air Handling Unit), cooling AHU, sensor chamber, and heat exchanger testing unit was designed and manufactured in this study. The performance of heat exchanger with porous polyurethane foam matrix was tested with variations of the density and the thickness of matrix, regulating the wind velocity and the rotational speed of matrix. The actual heat recovery effectiveness, air leakage rate, and pressure drop of heat exchanger were measured and analyzed.

  • PDF

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

Development of the Activity Type Smart Concrete using the Glass Pipe

  • Kim, Ie-Sung;Kim, Wha-Jung
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.29-32
    • /
    • 2005
  • A various structural materials are used in construction projects such as a stone, concrete, steel materials. Between of them, concrete are used widely. The compressive strength of concrete is high, and its maintenance and management is comparatively easy. The R.C Building will be superannuated as time passes. This program is generated by propagation of cracks. In order to manage such cracks, time and efforts, expense, etc. are required. In this study, glass sensors were embedding in a model beam and column and leakage of fluorescence and adhesive material was investigated. Further, currents in glass pipe were observed to find the leakage of liquid in glass pipes. Progressive cracks generated by cause the fracture of glass pipes. Therefore, the liquid become to flow and electric current stops, and the cracked part of the member can be found easily. Moreover, the adhesive delays progressive cracking system that responds in air, and the life of a structure can be made to extend. The purpose of this research is to develop of low price sensors that can perform of self-diagnosis in addition to ability of concrete repair concrete to damage.

발전소 급수계통 부식생성물 농도 측정에 관한 연구 (Study on The Measurement of Corrosion Product Concentration in The Feed Water System of A Power Plant)

  • 문전수;이재근
    • Corrosion Science and Technology
    • /
    • 제10권4호
    • /
    • pp.151-155
    • /
    • 2011
  • The iron oxide particles could be resulted from the corrosion of the circulating water system of a power plant. Because it may be one of the trouble materials which affect the power generation efficiency due to the deposition on steam generator tube and turbine blade, the continuous observation of its concentration is very important. The laser induced break-down detection (LIBD) technology was applied to monitor continuously the concentration of corrosion products with the detection limit of ppb level. The measurement system consists of a Nd:YAG pulsed laser, a polarizing beam splitter, a flow-type sample cell, an acoustic emission sensor, a high speed data acquisition board, a personal computer, etc.. The performance test results confirmed that this technology can be effective to monitor the corrosion product concentration of the circulating water system of a power plant.

스마트폰 레이싱 게임 조작기 UX 평가 (Smartphone racing game controller UX testing)

  • 정동훈
    • 디지털산업정보학회논문지
    • /
    • 제11권4호
    • /
    • pp.143-154
    • /
    • 2015
  • This study aims to evaluate smartphone gaming controllers. Diffusion of smartphone makes its users to play smartphone games in ease and comfort and its built-in sensors deliver new gaming experience to the users. Based on the concept how the controller system is important, the current research also implies the importance of customizing service which gives users a selection to deploy a controller. To explore the interaction effect of controllers and customizing on interactivity, flow, usability, attitude, and intention, the research constructs 3(gyroscope, wheel, and button controllers) by 2(default and customizing setting) experimental design and forty college students played Gameloft's Asphalt 8: Airborne in a within subject design. The results showed that interaction effect and customizing main effect were not found, but controller main effect was statistically significant. Button controller is superior to those other two in more detail. It implies that it is still not useful to play new types of gaming controller, and a customizing service. It suggests that smartphone games should more focus on improving optimal user experience with built-in sensor controllers.

실내 복도 환경에서 선분 특징점을 이용한 비전 기반의 지도 작성 및 위치 인식 (SLAM with Visually Salient Line Features in Indoor Hallway Environments)

  • 안수용;강정관;이래경;오세영
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.40-47
    • /
    • 2010
  • This paper presents a simultaneous localization and mapping (SLAM) of an indoor hallway environment using Rao-Blackwellized particle filter (RBPF) along with a line segment as a landmark. Based on the fact that fluent line features can be extracted around the ceiling and side walls of hallway using vision sensor, a horizontal line segment is extracted from an edge image using Hough transform and is also tracked continuously by an optical flow method. A successive observation of a line segment gives initial state of the line in 3D space. For data association, registered feature and observed feature are matched in image space through a degree of overlap, an orientation of line, and a distance between two lines. Experiments show that a compact environmental map can be constructed with small number of horizontal line features in real-time.